Place RUN / STOP switch to STOP to stop
unit.

1

1

FOR YOUR

PROTECTION 

Safety

Your  CARRIER product has been designed to meet all
European Safety requirements.

Please take notice of all stickers that have been placed on
this product for your safety. They are for your PROTECTION !

Beware of HIGH VOLTAGE (up to 700V) supplied by the
generator as the unit may start automatically. Before servi-
cing unit, make sure the RUN/STOP switch is in STOP position
and disconnect the negative battery cable.

Pacemaker holders must stay clear of the unit while operating
as the power generator supplies HIGH VOLTAGE.

Never dis-assemble the generator 
HIGH MAGNETIC FIELD INSIDE.

The refrigerant contained in the refrigeration system
of your unit can cause frosbite, severe burns, or blind-
ness when in direct contact with the skin or eyes.

Replace cover after servicing battery to insure protection of
battery and terminals.

Disconnect battery before doing any electrical welding on unit or
trailer. This unit has a negative ground system. Do not reverse polarity.
Reverse polarity will cause immediate failure of electrical system.

Top up coolant into recovery bottle only.
Fill empty radiator through filler neck slowly to avoid air
entrapment.
Remove filler cap slowly.

Unit may start automatically.

Beware of fan blades and pulleys.

Beware of electric heaters.

Summary of Contents for Transicold Vector

Page 1: ...AGES SPELLED OUT IN 8 LANGUAGES MESSAGES SPELLED OUT IN 8 LANGUAGES 500 CARRIER SERVICE STATIONS in EUROPE FORMER SOVIET UNION MIDDLE EAST and AFRICA Our company is constantly seeking to improve the q...

Page 2: ...d disconnect the negative battery cable Pacemaker holders must stay clear of the unit while operating as the power generator supplies HIGH VOLTAGE Never dis assemble the generator HIGH MAGNETIC FIELD...

Page 3: ...RT STOP CONTINUOUS SELECT TRIP START FUNCTION CHANGE DATA PRETRIP EASY TO RUN Standby Operation SETPOINT BOX TEMPERATURE START RUN STOP 1 0 STANDBY ENGINE LANGUAGE CONTINUOUS RUN START STOP ALARM DEFR...

Page 4: ...START STOP MODE SELECTED is displayed on the message center and that the START STOP light is illuminated EASY TO RUN Manual Operation SETPOINT BOX TEMPERATURE START RUN STOP 1 0 STANDBY ENGINE LANGUAG...

Page 5: ...P CONTINUOUS key until the CONTINUOUS RUN light on the controller illuminates EASY TO SELECT Manual Defrost SETPOINT BOX TEMPERATURE START RUN STOP 1 0 STANDBY ENGINE LANGUAGE CONTINUOUS RUN START STO...

Page 6: ...essage center will show TO SCROLL THEN TO SAVE The setpoint display will flash for 5 seconds if has not been pressed Verify that the message SETPOINT CHANGED is displayed on the message center Press t...

Page 7: ...ESS TO VIEW SETTINGS will appear Press the UP or DOWN ARROW to scroll through the Function list TO SCROLL THEN TO SELECT will appear 3 3 To change one of the Functions bring the Function you wish to c...

Page 8: ...he list of alarms If there are active alarms in the alarm list the display will be A and the alarm message for the latest active alarm in the list for 5 seconds 2 2 3 3 When you reach the end of the a...

Reviews: