background image

2

NOTE

: If 2 dashes (----) appear, your thermostat does not include

the outdoor temperature function or the function is not working
properly. Check with your dealer if you are unsure.

Service filter feature

Your thermostat reminds you when it’s time to change or clean

your filter by displaying the SERVICE FILTER indicator.

1. Press the RESET FILTER button after you have changed or

cleaned your filter to restart the timer.

A08149

Fig. 1 -- Battery Change

Battery change out

If the installation requires the usage of batteries, the batteries will
require replacement every 12 months.

1. Grasp the front housing of the thermostat along the left side.
2. Carefully pull the front housing away from the back mount-

ing base.

3. Find the two AA batteries along the bottom in back of the

front housing.

4. Remove the batteries from the back of the front housing.
5. Install two new AA Alkaline batteries following the + / --

polarity markings.

6. Carefully align the front housing with the plastic guides on

the right side of the back mounting base.

7. Carefully swing the left towards the back mounting base

until it snaps into place.

NOTE

: If installation is hard--wired, batteries are not required or

will not need replacement.

AUTO CHANGEOVER

Your thermostat provides complete, automatic control over heating

and cooling with auto changeover. Auto changeover means your

system will automatically heat or cool as needed to maintain your
temperature set points.
Auto changeover makes life easier because you no longer have to
manually switch the thermostat between heating or cooling

operation. Just set your heating and cooling set points and let the

system do the rest!

NOTE

: If auto changeover is not necessary in your area of the

country, your installer may disable the AUTO mode feature.

WHAT IF...

The AUXILIARY HEAT indicator is displayed...

The AUX HEAT indicator appears on the heat pump version of the

thermostat only. It is displayed when your system is operating on
auxiliary heat.

NOTE

: This indicator does not reflect a problem with your

system.

The SERVICE FILTER indicator is displayed...

The SERVICE FILTER indicator tells you when to clean or replace

your air filter. Press the RESET FILTER button after cleaning or
replacing the filter to turn off the indicator and reset the system.

NOTE

: This indicator does not reflect a problem with your

system.

You have a system error message...

The temperature sensor failure indicator sends a “----” reading to the
LCD display. This means your thermostat’s temperature sensor is

no longer able to measure temperatures. You will need to contact

your dealer to repair the problem.
An E2 reading on the LCD display means there is not enough

voltage for the system to operate. Contact your dealer for further
information.
If the outdoor air temperature sensor is absent, the outdoor
temperature reading will be “----”.

The batteries are low...

If the batteries are low, the display will indicate a low battery signal

on the thermostat. Replace the batteries with two AA alkaline

batteries.

NOTE

: If the product is hard--wired by the installer, the batteries

will never have to be replaced.

COMMON TERMS

Auxiliary Heat

Most heat pump systems require a supplemental heating source,

called auxiliary heat, to maintain your comfort when outdoor
temperatures fall significantly. Your thermostat lets you know

when your home is being warmed with supplemental heat.

Service Filter

Your system’s air filter will require regular cleaning to reduce the
dirt and dust in the system and your indoor air. The SERVICE

FILTER indicator lets you know when it’s time to clean the filter.

Fan

Your system’s fan can run continuously or only as called for during
heating or cooling. Continuous operation helps with air circulation

and cleaning. Automatic operation provides energy savings. Press

the FAN button to make your choice.

Mode

Mode refers to the type of operation your system is set up to
perform. Mode settings include: OFF, HEAT, COOL, and AUTO.

Heat pump systems also include EMERGENCY HEAT (EHEAT).

Reset Filter

The reset filter function turns off the SERVICE FILTER indicator
and restarts the system. Press the RESET FILTER button after

you’ve cleaned and replaced the system’s air filter.

Set Point

The heating and cooling temperature set points you wish the
system to maintain and have entered into the thermostat. The actual

room temperature will automatically be displayed, but you can
check the desired temperature by pressing either the UP or DOWN

button. While the SET TEMP indicator is lit, press the MODE

button to display the desired temperature set points for the other
mode.

Temperature Sensor

The temperature sensor measures the current indoor or outdoor

temperatures which are displayed on the thermostat.

Up and Down Buttons

These buttons are used to set your desired temperature set points.
This thermostat includes a five--year limited warranty. For detailed

warranty information, please refer to the All Product Limited
Warranty Card included in your information packet. This

thermostat is also eligible for manufacturer’s extended system

warranties. Ask your dealer for details on extended warranties for
longer--term protection.

Copyright 2008 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Printed in China

Edition Date: 03/08

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: TCSNAC---01SI

Replaces: NEW

Summary of Contents for TCSNAC01

Page 1: ...dels There are 2 different models The 5th and 6th letters of the part number indicate the model These 2 letters also appear on the package and on the circuit board Be sure to have the proper thermostat for the intended application Models are AC 1 stage cool 1 stage heat for AC systems only HP 1 stage cool 2 stage heat for either HP or AC with 2 stage heat Use each only for its intended purpose See...

Page 2: ... 1 4 6mm of extra wire Strip only 1 4 6mm of insulation from each wire to prevent adjacent wires from shorting together when connected 8 Match and connect equipment wires to proper terminals of the connector blocks See Table 1 ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation Improper wiring or installation may damage the thermostat Che...

Page 3: ...lable Option 02 values of OF and 1 through 9 Factory default is 2 5 Press MODE button again to return to Option 02 The SET icon will now be off 6 Use up and down buttons to select another Option or press FAN button to exit configuration mode OPTION 03 FAHRENHEIT CELSIUS SELECTION This option selects Fahrenheit or Celsius operation To Select 1 Enter configuration mode if not already there 2 Use up ...

Page 4: ... not already there 2 Use up and down buttons to display Option 15 The SET icon should be off 3 Press MODE button once The SET icon will come on The display now shows Option 15 setting 4 Use up and down buttons to move between available Option 15 choices of ON or OF Factory default is ON 5 Press MODE button again to return to Option 15 The SET icon will now be off 6 Use up and down buttons to selec...

Page 5: ...ree then first and second stages if a second stage exists will turn on for three minutes 4 If the mode is set to EHEAT auxiliary heat turns on for three minutes then the mode returns to OFF Terminating Installer Test After 15 minutes of inactivity no button presses by the installer thermostat will automatically revert to normal operation Pressing RESET FILTER any time during installer test will te...

Page 6: ...ck the furnace into low heat operation and let O B control high heat operation Refer to indoor equipment Installation Instructions for proper setup 4 O B can control second stage heat Refer to indoor equipment Installation Instructions for proper setup 5 Refer to outdoor equipment Installation Instructions for latent kit requirements if any 6 Terminals marked with may not be present on equipment 7...

Page 7: ...ashing the equipment is temporarily prevented from turning on by one of the timers see above While the icon remains on without flashing the equipment is on Power On Check When AC power is first applied all segments of the display are turned on for a few seconds Following this the temperature display indicates the model configuration via the following 2 digit code AC 1 speed air conditioner HP 1 sp...

Page 8: ...10 W Morris St S Indianapolis IN 46231 Printed in China Edition Date 03 08 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No TCSNAC 01SI Replaces NEW TCSN ...

Page 9: ... displayed when the cooling equipment is operating HEAT ON Indicator is displayed when the heating equipment is operating RESET FILTER Button restarts the timer that calculates the next air filter change or cleaning AUXILIARY HEAT Indicator is displayed when a heat pump system is operating with auxiliary heat air filter SETTING OPERATING THE THERMOSTAT Setting your indoor temperature set points 1 ...

Page 10: ...reading on the LCD display means there is not enough voltage for the system to operate Contact your dealer for further information If the outdoor air temperature sensor is absent the outdoor temperature reading will be The batteries are low If the batteries are low the display will indicate a low battery signal on the thermostat Replace the batteries with two AA alkaline batteries NOTE If the prod...