5
Model 20
Safety
080916
Section 3
Safety
We at Taylor are concerned about the safety of the
operator when he or she comes in contact with the
equipment and its parts. Taylor has gone to extreme
efforts to design and manufacture built--in safety
features to protect both you and the service technician.
IMPORTANT -- Failure to adhere to the
following safety precautions may result in severe
personal injury. Failure to comply with these
warnings may damage the machine and its
components. Component damage will result in
part replacement expense and service repair
expense
.
To Operate Safely:
DO NOT
operate the equipment without
reading this operator’s manual. Failure to follow this
instruction may result in equipment damage, poor
equipment performance, health hazards, or personal
injury.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipments frame.
DO NOT
use a water jet to clean or rinse this
equipment. Failure to follow these instructions may
result in serious electrical shock.
S
DO NOT
operate this equipment unless it is
properly grounded.
S
DO NOT
operate this equipment with larger
fuses than specified on the equipment data
label.
S
DO NOT
attempt any repairs unless the
main power supply to the equipment has
been disconnected. Contact your local
authorized Taylor Distributor for service.
S
Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
S
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.