48VG: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

1

c

Owner’s Information Manual

A09033

Fig. 1 – Unit 48VG

Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may

vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.

48VG 

Performance™ 15 and 16 SEER

2-Stage Packaged Air Conditioner and Gas Furnace

System With Puron® (R-410A) Refrigerant

Single and Three Phase

2-5 Nominal Tons (Sizes 24-60)

Technician Name

Phone Number

Address

Company Name

Date Installed

NOTE TO EQUIPMENT OWNER:

For your convience, please record the model and serial numbers of your new equipment in the spaces 
provided. This information, along with the installation data and dealer contact information, will be
helpful should your system require maintenance or service.

UNIT INFORMATION

ACCESSORIES (List type of model #)

INSTALLATION INFORMATION

DEALERSHIP CONTACT INFORMATION

This manual must be left with the eqipment owner.

NOTE TO INSTALLER:

Model # 

Serial #

Summary of Contents for Performance 48VG Series

Page 1: ...rmance 15 and 16 SEER 2 Stage Packaged Air Conditioner and Gas Furnace System With Puron R 410A Refrigerant Single and Three Phase 2 5 Nominal Tons Sizes 24 60 Technician Name Phone Number Address Company Name Date Installed NOTE TO EQUIPMENT OWNER For your convience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation...

Page 2: ...product is used in or around the home or business that the dwelling be equipped with a CO Alarm s The Consumer Product Safety Commission recommends the use of CO Alarm s The CO Alarm s must be installed operated and maintained according to the CO Alarm manufacturer s instructions For more information about Carbon Monoxide local laws or to purchase a CO Alarm please visit the following website http...

Page 3: ...urners do not light by the 4th ignition try of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death and or property damage 1 Do not turn off the electrical power to unit without first turning off the gas supply 2 Before at...

Page 4: ... with the following facts Cooling Mode With the SYSTEM control set to COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot days your unit will run for longer periods at a time and have shorter off periods than on moderate days Gas Heat Mode With the SYSTEM or MODE control of your indoor thermostat set to HEAT your unit will...

Page 5: ...e following information is given to assist in changing filters used in these internal filter racks Filter kits are available as a purchased accessory or a factory installed option The same filter kit is included with the accessory economizers and factory installed economizers Units with bent indoor coil CAUTION UNIT OPERATION HAZARD Failure to follow this caution may result in property damage Neve...

Page 6: ...ations and designs without notice and without obligations 6 A13035 Fig 4 To Start Unit Gas Heat 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 460 VAC MODELS 72 STEP 10 STEP 6 460 VAC MODELS STEP 9 O P E N STEP 5 208 230 VAC MODELS STEP 6 208 230 VAC MODELS ...

Page 7: ...s and designs without notice and without obligations 7 A13036 Fig 5 To Shut off Unit Gas Heat A09194 Fig 6 To Start Unit Electric Cooling 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 460 VAC MODELS STEP 5 208 230 VAC MODELS 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 ...

Page 8: ... Outdoor Fan The fan must be kept free of all obstructions to ensure proper cooling Contact your dealer for any required service Electrical Controls and Wiring Electrical controls are difficult to check without proper instrumentation If there are any discrepancies in the operating cycle contact your local dealer and request service Refrigerant Circuit The refrigerant circuit is difficult to check ...

Page 9: ... this time Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation Start up and Service Instructions Warranty Certificate Your unit has a limited warranty Be sure to read the warranty carefully to determine the coverage for your unit Before you call for service check ...

Page 10: ...to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect temperature and pressure safety controls for damage X Inspect and clean if necessary burners and heat exchanger X Inspect and clean if necessary combustion air openings and vent hood X Check gas piping and shutoff valve for leaks X Check refrigerant system subcooling and or superheat system dependent ...

Reviews: