![Carrier Performance 13 38TXA Product Data Download Page 27](http://html.mh-extra.com/html/carrier/performance-13-38txa/performance-13-38txa_product-data_2561432027.webp)
27
Detailed cooling capacities* continued
See notes on pg. 38.
EVAP
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Capacity
MBtuh†
Total
Sys
kW**
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
Total Sens‡
38TXA036-33 Outdoor Section With CC5A/CD5AA042 Indoor Section
1050
72
40.4
19.6
2.15
39.0
19.2
2.40
37.4
18.6
2.66
35.6
18.0
2.96
33.4
17.3
3.28
30.9
16.4
3.64
67
38.0
25.3
2.14
36.4
24.8
2.38
34.6
24.1
2.65
32.5
23.3
2.94
30.4
22.4
3.24
26.5
20.9
3.57
63††
34.9
24.6
2.12
32.5
23.6
2.35
30.1
22.5
2.60
27.5
21.4
2.87
24.9
20.3
3.17
22.3
19.2
3.50
62
33.9
30.2
2.12
31.6
29.1
2.34
29.2
27.9
2.59
26.7
26.5
2.86
24.5
24.5
3.17
23.2
23.2
3.51
57
31.3
31.3
2.09
29.5
29.5
2.32
27.5
27.5
2.57
26.4
26.4
2.86
25.1
25.1
3.17
23.6
23.6
3.51
1200
72
41.0
20.3
2.20
39.7
19.9
2.45
38.1
19.4
2.72
36.2
18.9
3.02
33.9
18.1
3.34
31.4
17.3
3.70
67
38.5
26.5
2.19
37.0
26.1
2.43
35.0
25.3
2.69
33.1
24.7
2.99
30.9
23.9
3.30
26.9
22.4
3.62
63††
36.1
26.3
2.18
33.6
25.2
2.41
31.1
24.1
2.66
28.3
23.0
2.93
26.0
22.0
3.24
23.3
20.9
3.56
62
34.8
32.4
2.17
32.4
31.2
2.39
30.0
29.7
2.65
27.9
27.9
2.93
26.8
26.8
3.25
24.6
24.6
3.58
57
32.7
32.7
2.15
31.0
31.0
2.38
29.9
29.9
2.64
28.7
28.7
2.94
27.3
27.3
3.25
24.8
24.8
3.58
1350
72
41.4
20.9
2.25
40.2
20.6
2.50
38.2
19.9
2.76
36.4
19.4
3.06
34.2
18.8
3.38
31.7
18.2
3.75
67
39.0
27.8
2.24
37.4
27.3
2.48
35.5
26.7
2.74
33.5
26.1
3.03
31.2
25.4
3.35
27.2
23.8
3.68
63††
36.9
27.8
2.23
34.5
26.8
2.46
31.9
25.7
2.71
29.4
24.6
2.99
26.9
23.6
3.30
24.2
22.4
3.62
62
35.8
34.5
2.22
33.2
32.9
2.45
31.1
31.1
2.70
30.0
30.0
3.00
28.6
28.6
3.32
25.8
25.8
3.65
57
34.8
34.8
2.22
33.3
33.3
2.45
32.0
32.0
2.72
30.7
30.7
3.01
28.3
28.3
3.32
25.9
25.9
3.65
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
036
1.00
1.00
CK5PT
036
1.00
0.94
042
1.00
1.00
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CC5A/CD5AW
036
1.00
1.00
CC5A/CD5AA
036
1.00
0.93
CE3AA
036
1.00
1.01
042
1.00
0.92
042
1.00
0.99
CC5A/CD5AW
036
1.00
0.93
CF5AA
036
1.00
1.00
CE3AA
036
1.00
0.94
CK3BA
036
1.00
1.00
042
1.00
0.92
042
1.00
1.00
CK3BA
036
1.00
0.93
CK5A/CK5BA
036
1.00
1.00
042
1.00
0.92
042
1.00
1.00
CK5A/CK5BA
036
1.00
0.93
CK5A/CK5BT
036
1.00
1.00
042
1.00
0.92
042
1.00
1.00
CK5A/CK5BE
042
1.00
0.92
CK5A/CK5BW
036
1.00
1.00
CK5A/CK5BT
036
1.00
0.93
CK5PA
036
1.00
1.00
042
1.00
0.92
042
1.00
1.00
CK5A/CK5BW
036
1.00
0.93
CK5PT
036
1.00
1.00
CK5PA
036
1.00
0.93
042
1.00
1.00
042
1.00
0.92
CK5PW
036
1.00
1.00
CK5PE
042
1.00
0.92
F(A,B)4(A,B)N(F,B,C)
042
1.00
1.00
CK5PT
036
1.00
0.93
F(A,B)4(A,B)N(F,C)
036
1.00
1.00
042
1.00
0.92
FE4ANF
002
1.00
0.95
CK5PW
036
1.00
0.93
003
1.00
0.93
COILS + 58CV(A,X)110-20 VARIABLE SPEED FURNACE
005
1.03
0.94
CC5A/CD5AA
036
1.00
0.93
FG3AAA
036
1.00
1.02
042
1.00
0.93
FK4(C,D)NF
002
1.00
0.95
CC5A/CD5AW
036
1.00
0.93
003
1.00
0.93
042
1.00
0.94
005
1.03
0.94
CE3AA
036
1.00
0.94
FV4(A,B)NF
002
1.00
0.95
042
1.00
0.92
003
1.00
0.93
CK3BA
036
1.00
0.93
005
1.03
0.94
042
1.00
0.93
FX4(A,B)NF
036
0.97
0.99
CK5A/CK5BA
036
1.00
0.93
042
1.00
1.00
042
1.00
0.93
COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE
CK5A/CK5BE
042
1.00
0.92
CC5A/CD5AA
036
1.00
0.95
CK5A/CK5BT
036
1.00
0.93
CE3AA
036
1.00
0.96
042
1.00
0.93
042
1.00
0.94
CK5A/CK5BW
036
1.00
0.93
CK3BA
036
1.00
0.94
CK5PA
036
1.00
0.93
CK5A/CK5BA
036
1.00
0.94
042
1.00
0.93
CK5A/CK5BE
042
1.00
0.93
CK5PT
036
1.00
0.93
CK5A/CK5BT
036
1.00
0.94
042
1.00
0.93
CK5PA
036
1.00
0.94
CK5PW
036
1.00
0.93
CK5PE
042
1.00
0.93
CK5PE
042
1.00
0.92