CAUTION

This symbol indicates the possibility of property damage or serious consequences.

This product is intended for human comfort ONLY.
Do not block air inlets or outlets. Poor performance, increased running costs and reduce product 
life will result.
Do not place the unit in front of drapes, curtains or other hangings.

In case they fall against the air inlet.

The unit should be used in such a way that it is protected from moisture. Do not place any objects
on top of unit, especially the one containing water.
Do not control the system with main power switch.

It can cause fire or water leakage. 

Store the remote control out of reach of infants.

Failure to observe this may result in the batteries being swallowed or other accidents.

Always transport the unit in a vertical position.
Ensure the unit is securely placed on a stable, level surface.
Disconnect the unit when unused for long periods. Place and store away from direct sunlight.
Disconnect BEFORE cleaning or servicing.

This may result in electric shock.

Do not wet the housing or control panel or never use strong detergents, solvents or abrasive 
polish on the product.
Never remove any fixed cover.
Regular high level maintenance of the units is essential. 

Specialist MAINTENANCE is required to do deep-clean, lubricate and function check of all critical components. Contact a 
suitable service provider.

1. SAFETY PRECAUTIONS

This product contains fluorinated gases covered by the Kyoto Protocol 

Chemical Name of Gas

Global Warming Potential (GWP) of Gas

R410A

2088

CAUTION

1. Clearly write the charged refrigerant quantity on the
    refrigerant label using indelible ink.
2. Prevent emission of the contained fluorinated gas. Ensure
    that the fluorinated gas is never vented to the atmosphere
    during installation, service or disposal. When any leakage 
    of the contained fluorinated gas is detected, the leak shall
    be stopped and repaired as soon as possible.

3. Only qualified service personnel are allowed to access and 
    service this product.
4. Any handling of the fluorinated gas in this product, such as
    when moving the product or recharging the gas, shall comply
    under (EC) Regulation No. 842/2006 on certain fluorinated 
    greenhouse gases and any relevant local legislation.
5. Contact dealers, installers, etc., for any questions.

Summary of Contents for PC-09HPPD PD Portable

Page 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL ...

Page 2: ...icipality has established collection systems where electronic waste can be disposed of at least free of charge to the user 2 When buying a new product the retailer will take back the old product at least free of charge 3 The manufacture will take back the old appliance for disposal at least free of charge to the user 4 As old products contain valuable resources they can be sold to scrap metal deal...

Page 3: ... Inproper grounded may result in electric shock Do not use extension cord or share the same power outlet with other appliances Check the available power supply and resolve any wiring issues before installation and operation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In order to avoid a hazard due...

Page 4: ...ousing or control panel or never use strong detergents solvents or abrasive polish on the product Never remove any fixed cover Regular high level maintenance of the units is essential Specialist MAINTENANCE is required to do deep clean lubricate and function check of all critical components Contact a suitable service provider 1 SAFETY PRECAUTIONS This productcontains fluorinatedgases coveredby the...

Page 5: ...Outlet Drain Outlet 1 Upper Air Intake Power Cord Brackets Storage use only Louver FRONT VIEW REAR VIEW 3 1 2 4 5 7 9 8 15 14 13 12 6 10 11 Bottom Tray Drain Outlet Drain Outlet 2 11 12 13 14 15 Lower Air Filter Lower Air Intake Plug Socket Storage use only 2 2 ACCESSORIES Name of Accessories Q ty pc Shape Exhaust hose Adapter A Exhaust hose Adapter B Flat mouth 1 Exhaust hose Adapter C Round mout...

Page 6: ...HEAT Press this button to initiate unit s auto on off time TIMER Button Set the louver to auto swing or stop swinging SWING Button This lamp will be on while follow me function is activated FOLLOW ME Lamp It indicates the set temperature or auto timer setting While on DRY or FAN modes it indicates the room temperature LED Display In Cool Heat mode when the ambient temperature is lower higher than ...

Page 7: ...let or outlet of unit CAUTION 3 3 1 Window slider kit installation 3 PREPARING FOR OPERATION B A Clearance from other obstracles A 30cm 100cm B 30cm bolt Window slider kit Minimum 67 5cm Maximum 123cm Seal sponge Seal sponge Window slider kit Seal sponge Seal the gap between window sashes How to install the window slider kit Seal sponge Seal sponge Window slider kit Seal sponge Seal the gap betwee...

Page 8: ... B Exhaust Hose Adapter A 30 120cm 3 3 2 Wall installation 30 120cm Adapter C Exhaust Hose Adapter A Wall Exhaust adapter 3 3 3 The height of exhaust hose outlet Do not over bend the exhaust hose Cover the hold by using the adaptor cap wall installation when not in use NOTE ...

Page 9: ... for a long time system diagnostics may detect a malfunction and the unit will not operate properly Room relative humidity less than 80 If the air conditioner operates outside this range the surface of the air conditioner may attract condensation Dry Mode The unit should be placed within reach of a properly rated grounded socket Power plug must be securely inserted into the socket outlet Do not us...

Page 10: ...rt from that of DRY mode 2 Press MODE and select 3 Press on the unit or TEMP on the remote control to select the temperature 4 Press FAN on the unit or remote control to select the fan speed HEAT Mode 1 Press MODE and select 2 Press FAN on the unit or remort control to select the fan speed NOTE Temperature can not be adjusted under FAN mode FAN Mode Under HEAT Operation Special Functions NOTE Do n...

Page 11: ...ser settings are all recovered Auto Restart When the LED display shows P1 it means the bottom tray is full of water and needs draining The unit will stop automatically and can not be restarted until the water is drained 1 Move the unit to a drain location 2 Remove the bottom tray drain outlet cover and plug 3 After the water is fully drained put back the plug and cover 4 Switch on the unit until P...

Page 12: ...own when using water Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place Re install the air filter after ensuring filter is thoroughly dry Storage Preparation long idle periods 1 Clean the air filters 2 Make sure the unit is completely drained of wa...

Page 13: ... switch off all heat sources if possible Check that the exhaust air duct is connected properly and not blocked If blocked clean and re connect Clean the air filter and re fit securely before continuing operation Temperature setting is too high Lower the temperature Move the unit to a stable flat and level surface Case Explanation Solution Cooling or heating is delayed Unit does not start or there ...

Page 14: ......

Page 15: ......

Page 16: ...BEIJER RET AB Stortorget 8 Malmö Sweden ...

Reviews: