Parts

A200226A

Fig. 11 – Exploded View

Table 5 – Parts

1

2

3

7

6

8

4

9

11

12

17

18

19

20

21

19

10

5

14

13

16

15

3

Item # Qty

Description

Part Number - Model Size

005

006

015

1

1

Discharge 

Transition Plate

346303-701

346303-702

2

*

*. Not on 015 models manufactured after Sep 2020.

1

Power Cord

346284-401

N/A

346284-401

3

1

Strain Relief

346294-401

4

1

Motor

HD46AM126

HD46AM127

HD42AM120

HD42AQ120

HD52AM120

HD52AQ120

5

1

Blower Housing 

Assembly

342890-75103

342890-75105

6

2

Gasket, 6”

(152 mm)

346295-402

7

2

Gasket, 16”

(408 mm) or 

20” (506 mm)

346295-401

346295-403

8

2

Caster Assembly

346285-701

346285-702

9

1

HEPA Filter

346345-75101

346345-75102

10

1

Pre-filter, MERV 7

KH01AZ500

KH01AZ501

11

1

Lower Door 

Assembly

346279-701

346279-702

12

1

Upper Door 

Assembly

346277-701

346277-702

13

1

Door Filler Panel

N/A

346523-702

346523-701

346523-702

†. Door with hole for power cord (manufactured after Sep 2020).

14

1

Power Cord

N/A

346572-401

15

1

Junction Box

N/A

346661-401

16

1

J-Box Cover

N/A

346662-401

17

1

Indicator, red

346299-401

18

1

Power Switch, 

green, lighted

346300-401

19

1

Control Panel 

Plate

346297-402

346297-403

20

1

Pitot Tube

346301-401

21

1

Transformer

346305-401

22

1

Pressure Switch

HK06WD001

(not 

shown)

1

3-Speed Rotary 

Switch

N/A

HR56ZQ001

(not 

shown)

1

Pilot Tube Fitting

346289-401

(not 

shown)

1

Wiring Harness

346304-701

346349-701

Summary of Contents for OptiClean FN1AAF

Page 1: ...ve Air Machine NOTICE IMPORTANT INFORMATION Read all instructions and data in this manual before operating DO NOT apply power or turn on until the outer packaging plus the inside located parts box and cardboard under the filters have been removed from the unit See applicable Assemble the Unit Instructions herein Additional information and video assembly instructions are available online at opticle...

Page 2: ... its back in a horizontal orientation as long as there is sufficient space at either end for air intake and output Make sure to properly strap or otherwise secure it to a base to avoid unintentional movement When the unit is mounted horizontally an additional pre filter must be used See Table 2 9 Attach the caster assemblies ref Fig 2 to the bottom of the unit a Remove and retain the screws from t...

Page 3: ...izontal orientation as long as there is sufficient space at either end for air intake and output Make sure to properly strap or otherwise secure it to a base to avoid unintentional movement When the unit is mounted horizontally an additional pre filter must be used See Table 2 9 Attach the caster assemblies Fig 4 to the bottom of the unit a Remove the screws from the outer corners of the cabinet b...

Page 4: ...the green the power switch down to the OFF position 2 Unplug the unit from the wall outlet 3 Listen to make sure the blower wheel has stopped spinning and remove the bottom front door 4 Put on Personal Protective Equipment 5 Slide the pre filter out of the cabinet and immediately put it inside an approved containment bag Dispose per facility guidelines for hazardous materials 6 Replace the pre fil...

Page 5: ... airflows and connect the wires according to Table 3 The Red motor lead is energized when switch is set to LOW the Blue motor lead is energized when switch is set to MED NOTE The Blue and Gray motor leads are energized when switch is set to HIGH The factory HIGH speed setting is tap 4 this is assuming the product will be operated in Scrubber mode with an accessory diffuser If this is not the case ...

Page 6: ...ired for alternative CFMs See Airflow Adjustments on p5 1 3 Nominal CFM 500 200 400 600 500 1000 1500 BRN BLK L YEL N GRN YEL GND BLU 3 FM TRAN 115V FILTER LIGHT DIFFERENTIAL PRESSURE SWITCH C R 2 1 2a 1a N L1 POWER PLUG LIGHTED POWER SWITCH 24V BRN C BLK L YEL N GRN YEL GND BLU Medium FM GRY High RED Low C L G N 1 2 3 4 5 MOTOR CONNECTOR TRAN 115V FILTER LIGHT DIFFERENTIAL PRESSURE SWITCH C R 2 1...

Page 7: ...6295 402 7 2 Gasket 16 408 mm or 20 506 mm 346295 401 346295 403 8 2 Caster Assembly 346285 701 346285 702 9 1 HEPA Filter 346345 75101 346345 75102 10 1 Pre filter MERV 7 KH01AZ500 KH01AZ501 11 1 Lower Door Assembly 346279 701 346279 702 12 1 Upper Door Assembly 346277 701 346277 702 13 1 Door Filler Panel N A 346523 702 346523 701 346523 702 Door with hole for power cord manufactured after Sep 2...

Page 8: ...d Edition Date 2 21 Catalog No OM FN1AAF 05 Replaces OM FN1AAF 04 FN1AAF Operation and Maintenance Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 8 Notes ...

Reviews: