Parts

A200226

Fig. 9 – Exploded View

1

2

3

7

6

8

4

9

11

12

13

14

15

16

17

18

10

5

Item # Qty

Description

Part Number - Model Size

005

015

1

1

Discharge Transition Plate

346303-701

346303-702

2

1

Power Cord

346284-401

3

1

Strain Relief

346294-401

4

1

Motor

HD46AM126

HD52AM120

5

1

Blower Housing Assembly

342890-75103 342890-75105

6

2

Gasket, 6” (152 mm)

346295-402

7

2

Gasket, 16” (408 mm) or 

20” (506 mm)

346295-401

346295-403

8

2

Caster Assembly

346285-701

346285-702

9

1

HEPA Filter

346345-75101 346345-75102

10

1

Pre-filter, MERV 7

KH01AZ500

KH01AZ501

11

1

Lower Door Assembly

346279-701

346279-702

12

1

Upper Door Assembly

346277-701

346277-702

13

1

Indicator, red

346299-401

14

1

Power Switch, green, lighted

346300-401

15

1

Control Panel Plate

346297-402

346297-403

16

1

Pitot Tube

346301-401

17

1

Transformer

346305-401

18

1

Pressure Switch

HK06WD001

(not 

shown)

1

3-Speed Rotary Switch

N/A

HR56ZQ001

(not 

shown)

1

Pilot Tube Fitting

346289-401

(not 

shown)

1

Wiring Harness

346304-701

346349-701

Summary of Contents for OptiClean FN1AAF 005

Page 1: ...rd MERV 7 or higher pre filter Minimum 500 CFM and Maximum 1500 CFM Meets or exceeds ASHRAE Standard 170 Ventilation of Health Care Facilities Vertical design for smaller footprint compared to many competitors and can be mounted and operated horizontally when necessary Portable and adaptable to nearly any location Heavy duty locking casters for easy and smooth transport HEPA filter rack and sealin...

Page 2: ... Remove the bottom front door then the top door over the blower section Inspect the HEPA filter and make sure it has not been dislodged or damaged during shipping that the side bolts and nuts near each corner are tight and the HEPA filter is held securely in place and the seal around the top edge of the filter is in place 9 Make sure the first stage pre filter is in place and not damaged 10 Replac...

Page 3: ...se a 1 2 inch open end or adjustable wrench to remove the bottom nuts from the all thread bars on both sides four nuts total 7 Slide the bottom HEPA filter supports down along with the filter and out of the unit 8 Remove the HEPA filter and immediately put it inside an approved containment bag Dispose per facility guidelines for hazardous materials 9 Position the new HEPA filter into the unit with...

Page 4: ...ting and or repairs be sure to have the model and serial numbers of your equipment available Specifications A200223 Fig 7 005 Model Wiring Diagram A200258 Fig 8 015 Model Wiring Diagram Switch Setting Motor Lead Motor Tap Options LOW Red 1 2 3 Switch Setting Motor Lead Motor Tap Options MED Blue 2 3 4 Switch Setting Motor Lead Motor Tap Options HIGH Gray 5 Table 2 Electrical Specifications 005 Mod...

Page 5: ...103 342890 75105 6 2 Gasket 6 152 mm 346295 402 7 2 Gasket 16 408 mm or 20 506 mm 346295 401 346295 403 8 2 Caster Assembly 346285 701 346285 702 9 1 HEPA Filter 346345 75101 346345 75102 10 1 Pre filter MERV 7 KH01AZ500 KH01AZ501 11 1 Lower Door Assembly 346279 701 346279 702 12 1 Upper Door Assembly 346277 701 346277 702 13 1 Indicator red 346299 401 14 1 Power Switch green lighted 346300 401 15...

Page 6: ...dition Date 06 20 Catalog No OM FN1AAF 02 Replaces OM FN1AAF 01 FN1AAF Operation and Maintenance Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 6 Notes Page ...

Reviews: