FN1AAF: Operation and Maintenance Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
5. Locate the three blower speed tap wires (red, blue, and gray)
attached to the blower motor (
).
6. Identify the correct Motor Tap for desired airflows and connect the
wires according to
– The Red motor lead is energized when switch is set to LOW, the
Blue motor lead is energized when switch is set to MED.
NOTE:
The Blue and Gray motor leads are energized when switch is set
to HIGH. The
Gray lead should remain on Motor Tap 5
in order to
assure that red filter/obstruction indicator is properly detecting filter
condition.
A200258
Fig. 6 – Motor Taps
7. Replace the top door screws.
8. Tighten the bottom door screws.
Table 1 – Blower Configuration
Altitude Adjustments
Depending on your location, you may see up to 10% increase of
measured airflow at higher altitudes. To compensate, you can change
motor taps for alternate airflows
.
Troubleshooting
Before you request dealer service, check for these easily solved
problems:
• Check your main electrical panel circuit breakers or fuses if the unit
will not turn on.
• Make sure the unit is plugged in to a working 115V electrical outlet.
• Check for sufficient airflow. Filters should be clean and unobstructed.
If you need to contact your authorized dealer for troubleshooting and/or
repairs, be sure to have the model and serial numbers of your equipment
available.
Specifications
A200223
Fig. 7 – 005 Model Wiring Diagram
A200258
Fig. 8 – 015 Model Wiring Diagram
Switch Setting
Motor Lead
Motor Tap Options
LOW
Red
1
2
3
Switch Setting
Motor Lead
Motor Tap Options
MED
Blue
2
3
4
Switch Setting
Motor Lead
Motor Tap Options
HIGH
Gray
5
Table 2 – Electrical Specifications
005 Model
015 Model
Voltage
115
Hertz
60
Amps
5.0
12.0
Speeds
*
*.
005 model
has a green lighted power switch only; wired to tap 5 from
the factory.
015 model
has the green lighted power switch, plus 3-speed rotary
switch; wired to taps 1, 3, and 5 from the factory. Taps 2 and 4 can be
field-wired for alternative CFMs. See
1
3
Nominal CFM
500
500 / 1000 / 1500
BRN
BLK - L
YEL
- N
GRN/YEL
- GND
BLU - 3
FM
TRAN
115V
FILTER
LIGHT
DIFFERENTIAL
PRESSURE
SWITCH
C
R
2
1
2a
1a
N
L1
POWER PLUG
LIGHTED
POWER SWITCH
24V
BRN - C
BLK - L
YEL - N
GRN/YEL - GND
BLU - Medium
FM
GRY - High
RED - Low
C L G N
1
2
3 4 5
MOTOR CONNECTOR
TRAN
115V
FILTER
LIGHT
DIFFERENTIAL
PRESSURE
SWITCH
C
R
2
1
2a
1a
N
L1
POWER PLUG
LIGHTED
POWER SWITCH
24V
LEGEND
WIRING
COMMON
FUSE
GROUND
TRANSFORMER
C
TRAN
FM
FAN MOTOR
CONNECTION POINT
NORMALLY OPEN
NORMALLY CLOSED
DOUBLE POLE DOUBLE THROW
NO
NC
DPDT
C
L
G
N
1
2
3
4
5
MEDIUM
LOW
HIGH
SPEED TAPS
POWER
CONNECTION
MOT
OR
CONNECT
OR
Æ
NO1
NC1
NO2
NC2
C1
C2
SWITCH
POSITION
DPDT
3 SPEED SWITCH
NO1
NC1
NO2
NC2
C1
C2
LEFT
Æ
LOW
SPEED
NO1
NC1
NO2
NC2
C1
C2
CENTRE
Æ
MEDIUM
SPEED
NO1
NC1
NO2
NC2
C1
C2
RIGHT
Æ
HIGH
SPEED
RED
BLU
GRY
RED
BLU
GRY
BLK
YEL
GRN/YEL
BLK
BRN 24V
BLK
11
12
14
24
21
G