2

Color

Mode

Suggested Use

Green

Intermittent

Select this mode when you are away from the house for a few days, or when
you deem the inside air is too dry in heating season or too humid in cooling
season. In this mode the unit is OFF for 40 minutes per hour and ventilates at
minimum speed the remaining 20 minutes of the hour.

Yellow

Minimum Speed

Ventilation

For normal daily operation

Red

Maximum Speed

Ventilation

For excess pollutants and humidity
(Parties, odors, smoke, etc.)

INSTALLATION

Step 1—

Cut a 2 3/8 in. high by 1 3/8 in. wide hole in the wall.

See Fig. 1.

Step 2—

Temporarily place the switch in the hole to mark the

correct locations for the 2 wall anchors.

Step 3—

Remove the switch, drill the 2 wall--anchor holes and

insert the wall anchors into the wall.

Step 4—

Using Fig. 2 as a guide, connect the electrical wiring.

Step 5—

Finish mounting KVBCN0101CLT wall control. Plug

the unit in and test the wall control operation.

1-- 3/8 in.

2-- 3/8 in.

A05291

Fig. 1 -- Wall Control Installation

NO  C  NC   I   OC OL  Y   R    G   B

B

G

OC

KVBCN0101CLT Control

REAR VIEW

G B

Y

A05292

Fig. 2 -- Wall Control Wiring