GB - 5
NTC - IR2
E N G L I S H
Confi guration menu
Refer to the
fi
gure at page 3 (Aspect and display).
With the remote control OFF press button B for at least 5 seconds
to access to the con
fi
guration menu. “1-” is displayed: this is the
fi
rst settable item of the menu. To check this item
ʼ
s value press but-
ton B again. The default value is displayed
fi
rst.
To change this value, press button F or D. Press E to save the new
setting. To display and/or change another item (“2-”) press button B
and repeat the steps above.
If no button is pressed within 60 seconds, the system quits the
menu automatically. No message is sent.
The con
fi
guration menu is described in the following table:
1-
2-
3-
Item
Value
Description
Displayed
Temperature
units
C: Degrees C
F: Degrees F
System
Co
St
Set - point displaying
Ye
No
˚
C -indicates that all temperatures will be displayed in
degrees
C.
˚
F -indicates that all temperatures will be displayed in
degrees
F.
[Defaults:
"C":
Degrees
˚
C]
Temp SP is shown thru bar graph
Temp SP is shown thru the 7 segments digits and .5 icon
[Defaults:
"Co":
Communicating]
The set-point value will be displayed on the IR2 lcd
The set-point value will be NOT displayed on the IR2 lcd
[Defaults:
"Ye"]
NO
NO
YES
If "System" is Co, the
set - point will be not
displayed automatically.
4-
5-
6-
7-
8-
Set-point
value
15,16,17,18,19,20,21,
22,23,24,25,26,27,28,
29,30,31,32
˚
C
59,60,61,62,63,64,65,
66,67,68,69,70,71,72,
73,74,75,76,77,78,79,
80,81,82,83,84,85,86,
87,88,89,90
˚
F
Reset step value
0;0,5;1;1,5;2
˚
C
0;1;2;3;4
˚
F
Fan speed type
F
U
Blind groups available
0
1
…
4
5
Blind
Inclination
No
Ye
[Defaults:
22
˚
C; 72
˚
F]
[Default: "0,5"
˚
C; "1"
˚
F]
Fixed
speed
Variable fan speed
[Default: "F" 3
fi
xed speeds]
There is no blind/groups to control: no icons will be
displayed
Just one blind group is available: “1” group icons will not
be illuminated
…
Four lights groups are available: “Lamp” and “4”
groups icons will be illuminated in the light menu
There is no group, but user can manage the blind
[Defaults: “0”: Blinds control disabled.]
The installed blinds doesn
ʼ
t have the capability to
modify its inclination
The installed blinds has the motor able to change
its inclination.
[Default: “No” Blinds doesn
ʼ
t have the capability to
change its inclination]
NO
YES
If the reset step value is
set to 0, the stand alone
mode is not available. The
IR remote control and its
display, work as in
communicating mode
NO: In case of variable fan,
the icons available are
two: HIGH speed and
AUTO
mode
YES: Once the blind menu
is selected, the groups icon
will be energized on the
lcd (no icons if just one
group is selected)
“A” and “1” icons are
energized in the blind
menu. User can manage
all blinds or just one
NO
The blind inclination
feature becomes active
into the Blind Menu. No
icon point out this feature
out of the blind menu
Summary of Contents for Infrared Remote 2
Page 2: ......
Page 4: ......
Page 13: ...NTC IR2 I 2 Dimensioni mm 28 61 181 63 2 5 32 8 77 2 85 7 87 A Sostegno a parete Telecomando...
Page 20: ...NTC IR2 F 2 Dimension mm 28 61 181 63 2 5 32 8 77 2 85 7 87 A Support mural T l commande...
Page 27: ...NTC IR2 D 2 Abmessungen mm 28 61 181 63 2 5 32 8 77 2 85 7 87 A Wandhalterung Fernbedienung...
Page 40: ...NTC IR2 NL 2 28 61 181 63 2 5 32 8 77 2 85 7 87 A Wandhouder Afstandsbediening Afmetingen mm...
Page 47: ...K GR 1 NTC IR2 mm 2 3 4 4 5 6 6 7 IR2 IR2...
Page 48: ...NTC IR2 GR 2 28 61 181 63 2 5 32 8 77 2 85 7 87 A mm...
Page 50: ...NTC IR2 GR 4 1 5 7 7 beep 7 1 2 1 2 2 2 1 5 8 0 2 0 1 1 M V V 25 mm 0 984 in 5 mm 0 196 in...
Page 62: ...NTC IR2 S 2 28 61 181 63 2 5 32 8 77 2 85 7 87 A V ggh llare Fj rrkontroll M tt mm...
Page 69: ...NTC IR2 FIN 2 28 61 181 63 2 5 32 8 77 2 85 7 87 A Sein teline Kaukos din Mitat mm...
Page 75: ......