5

SAM SETUP 1

AUX:

AUX SENSOR

IP TYPE:

DHCP

IP:

192.168.100.0

MAC ADDR:

00:01:02:03:04:05

SUBNET MASK:

255.255.255.000

SERVER
STATUS:

CONNECTED

< BACK

NEXT >

SAM SETUP 2

DEFAULT GATEWAY:

192.168.001.001

DNS SERVER:

061.010.231.015

PORT:

49152

SERVER
STATUS:

CONNECTED

< BACK

NEXT >

AUX:

With previous generation UID/UIZ systems,

the auxiliary sensor can be renamed to something meaningful, such as WATER or

GENERATOR. Use the Temp +/-- buttons to move between letters, and the Time +/-- button to choose letters.

For newer generation Infinity

Touch systems

, this input is always labeled “SAM AUX SENSOR ALERT”.

The following items are for use with the previous generation UID/UIZ systems, only:

IP TYPE:

Choose DHCP (default) or STATIC for the Internet addressing type.

IP:

Shows the current IP address of the CAT--5 B--SAM. If IP TYPE is STATIC then this item can be changed. Use the Temp +/-- buttons to

move between numbers, and the Time +/-- button to choose numbers. If IP TYPE is DHCP, the IP address cannot change.

MAC ADDR:

Shows the MAC Address of the CAT--5 B--SAM’s network module.

SUBNET MASK:

If the IP TYPE is STATIC, this can be changed to a different subnet number. Use the Temp +/-- buttons to move between

numbers, and the Time +/-- button to choose numbers. If IP TYPE is DHCP, the SUBNET MASK cannot be changed.

DEFAULT GATEWAY:

If the IP TYPE is STATIC, this can be changed to point to a different gateway. Use the Temp +/-- buttons to move

between numbers, and the Time +/-- button to choose numbers. If IP TYPE is DHCP, the DEFAULT GATEWAY cannot be changed.

DNS SERVER:

If the IP TYPE is STATIC, this can be changed to point to a different DNS server. Use the Temp +/-- buttons to move

between numbers, and the Time +/-- button to choose numbers. If IP TYPE is DHCP, the DNS SERVER cannot be changed.

PORT:

This can be changed to use a different port through the homeowner’s network. The default is port 49152.

SERVER STATUS:

Shows status of the CAT--5 B--SAM connection to Carrier’s servers. If the screen shows NON CONNECTED, please

check network settings or network cable.

Home

Automation

Connection

(RS- 232)

STATUS

COMM1

COMM2

WLSC

WLS

A1

B1

C1

A2

B2

C2

SERIAL NUMBER

TEST

AUXILIARY

SENSOR

ABC TO

SYSTEM 1

ABC TO

SYSTEM 2

24VAC

Ethernet
Module

A06512

Fig. 1 -- CAT--5 Module Control Board