The newer Infinity Touch systems

utilize the SAM for ONLY

interface to Home Automation systems, utilizing the RS-232 serial

port connection. The Touch control DOES NOT support the SAM
web page on the LAN, nor connection to the LAN or Internet

through the CAT-5 B--SAM Ethernet port. Use the Wi-Fi version

of the Infinity Touch wall control when connection to the Internet
is desired.

NOTE

:

The SAM is designed for operation with the previous

generation UID/UIZ wall control systems. As such, it will operate
“as-is” with the newer Infinity Touch systems, and may display
status codes that are unique to the previous generation UID/UIZ
systems, but are irrelevant when the SAM is used with the newer
Infinity Touch systems. In addition, some features of the
RS-232/ASCII home automation interface will NOT be available
with the newer Infinity Touch systems. See the latest version of
the SAM Remote Access Interface Specification, available on
HVACpartners, for more details on the home automation
interface.

The CAT--5 B--SAM can also monitor a dry--contact sensor to
provide a warning for the presence of water in the building, or

some other use. If the sensor is active, the Infinity system will not
be disabled or shut down.

Computer Requirements

(Previous generation

UID/UIZ systems, only)

The CAT--5 B--SAM uses a web--based application to control and

monitor

the

Infinity

system.

This

application,

www.MyInfinity.Carrier.com, will work with any graphic user

interface PC operating system (Microsoft, Apple, Linux). The
web--based application is optimized for use with Microsoft’s

Internet Explorer version 6 and above. Other web browsers are

compatible with some possible screen formatting issues.

NOTE

:

This web--based application for the SAM is NOT

available for Infinity Touch systems. When using these systems,
Internet access is achieved using the Wi-Fi version of the Infinity
Touch control, and accessing the www.MyInfinityTouch.com
website.

SAM INSTALLATION

BEFORE STARTING:

S

SYSTXCCUID01 or SYSTXCCUIZ01 (version 14 software
revision or higher),

or

newer generation

SYSTXCCITN01, SYSTXCCITC01, or SYSTXCCITW01
(version 08 software revision or higher) wall control is
required.

Check Equipment and Job Site

INSPECT EQUIPMENT -- File claim with shipping company,

prior to installation, if shipment is damaged or incomplete.

Component Location and Wiring Considerations

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing, modifying, or servicing system, the main

electrical disconnect switch must be in the OFF position and

install a lockout tag. There may be more than one power

disconnect switch. Lock out and tag switch with a suitable

warning label.

!

WARNING

NOTE

: All wiring must comply with national, state, and local

codes.

LOCATING THE UNIT

-- CAT--5 B--SAM is approved for

indoor use only and should never be installed with any of its

components exposed to outdoor environmental conditions. The
CAT--5 B--SAM may be installed in any area where the

temperature remains between --4

_

F / --20

_

C and 158

_

F / 70

_

C,

and there is no condensation. The cover must be installed to
prevent damage from other sources. Do not locate where it will be

accessible to children. It should be mounted in the vertical position.
For wiring convenience, the CAT--5 B--SAM can be located

anywhere between the network router and HVAC equipment. The

CAT--5 B--SAM does not need to be located near the HVAC
equipment and can be located near the router, if a long Ethernet

cable run cannot be made.

NOTE

:

The Ethernet connection is NOT used for newer

generation Infinity Touch systems.

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage.
Do not mount unit on plenum, ductwork, or flush against

furnace.

CAUTION

!

WIRING CONSIDERATIONS -- Ordinary thermostat wire is ideal

when wiring the CAT--5 B--SAM into the HVAC system (shielded
cable is not necessary). Use 22--gauge or larger for normal wiring.

Lengths over 100 ft / 30 m should use 20--gauge or larger wire.

For previous generation UID/UIZ systems,

Local Area Network

(LAN) connections will require appropriate network wire --

CAT--5e cable is recommended.

Install Components

INSTALL CAT--5 B--SAM

The CAT--5 B--SAM is designed so that wires can enter it from

behind, above, or below. Plan wire routing before mounting.

1. Remove cover to access mounting holes.
2. Mount back plate to wall using screws and wall anchors

provided.

3. Level back plate and tighten screws.

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment

damage or improper operation.
Improper wiring of the ABC connector will cause the system

to operate improperly. Check to make sure all wiring is

correct before proceeding with installation or turning on of

power.

CAUTION

!

Connect Infinity Systems

Connect the A, B, and C wires from the Infinity system to

terminals labeled A1, B1, and C1. Connect the second Infinity
System (if present) to the terminals labeled A2, B2 and C2.
ABC bus wiring only requires a three--wire connection; however, it
is good practice to run thermostat cable greater than three wires in

the event of a damaged or broken wire during the installation.
It is recommended that the following color--code be used when
wiring each ABC connector:

A -- Green

Data A

B -- Yellow

Data B

C -- White

24VAC (Com)