58PHA/PHX PERFORMANCE™ BOOST 80

4---WAY MULTIPOISE

INDUCED---COMBUSTION GAS FURNACE

Input Capacities: 45,000 thru 135,000 Btuh

Series 110/120

Product Data

A10251

THE CARRIER PERFORMANCE

t

BOOST 80

GAS FURNACE

The 58PHA/PHX 4--way Multipoise Gas Furnaces offer deluxe

features not found in other single--stage 80% gas furnaces. The
ECM motor and Carrier’s control logic combine to provide a

SEER BOOST of up to 1.5 points.* Carrier’s QuieTech

t

noise

reduction system makes the Performance

t

Boost 80 an incredibly

quiet induced--draft gas furnace.
The gas furnace control system provides a dehumidification mode,
a motor speed selection for continuous fan operation selectable at

the thermostat, and fault code storage in the event of power
outages. Applications are easy with 4--way multipoise design,

through--the--furnace downflow venting, 13 different venting

options, and a design for easy service access. An inner blower door
is provided for tighter sealing in sensitive applications. The

58PHA/PHX furnaces are approved for use with natural or propane
gas, and the 58PHX is approved for use in Low NOx Air Quality

Management Districts.

STANDARD FEATURES

S

ECM Blower Motor included

S

QuieTech

t

noise reduction system

S

SmartEvap

t

—Humidity control when using a

Thermidistat

t

Control

S

ComfortFan

t

—adjustable constant fan speed from the

thermostat

S

Microprocessor based control center

Enhanced diagnostics with LED and reflective sight glass.
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow
Dehumidification selection for summer--time cooling

S

4--way Multipoise furnace, 13 vent applications

S

Compact design -- only 33--1/3 in. (847 mm) tall

S

Power Heat SiN

t

Igniter

S

Draft safeguard switch to ensure proper furnace venting

S

Insulated blower compartment

S

Inner door for tighter sealing

S

Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In.
Water Gauge with all present air inlets and air outlet sealed.

S

HYBRID HEAT

Dual Fuel System compatible

S

All models are chimney friendly when used with accessory
vent kit

S

Residential installations eligible for consumer financing
through the Retail Credit Program

*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil---only rating when paired with selected Carrier evaporator coils.

Summary of Contents for Infinity GAPAAXCC1625

Page 1: ...in Low NOx Air Quality Management Districts STANDARD FEATURES S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control S ComfortFant adjustable constant fan speed from the thermostat S Microprocessor based control center Enhanced diagnostics with LED and reflective sight glass Stores fault codes during power outages Adjustable ...

Page 2: ...LBOW MAIN LIMIT SWITCH BEHIND GAS VALVE BLOCKED VENT SWITCH FLAME SENSOR GAS MANIFOLD GAS BURNER BLOWER AND MOTOR MANUAL RESET LIMIT SWITCHES CAPACITOR POWER CHOKE A10314 NOTE The 58PHA PHX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion kit 58PHA ...

Page 3: ...8 219 219 5 1 2 5 1 2 140 3 140 3 8 7 16 8 7 16 213 5 213 5 FRONT OF CASING FRONT OF CASING TOP OF CASING TOP OF CASING 6 1 6 1 155 7 155 7 2 1 16 2 1 16 51 6 51 6 5 1 5 1 130 5 130 5 1 7 1 7 43 5 43 5 Ø7 8 Ø7 8 22 2 22 2 ACCESSORY 2 ACCESSORY 2 AIR FLOW AIR FLOW AIR FLOW AIR FLOW BOTTOM RETURN BOTTOM RETURN WIDTH WIDTH AIR FLOW AIR FLOW KNOCK OUTS FOR KNOCK OUTS FOR VENTING 5 VENTING 5 PLACES PLA...

Page 4: ...ntrol SPST Heating Blower Control Solid State Time Operation Burners Monoport 2 3 4 5 6 Gas Connection Size 1 2 in NPT GAS CONTROLS Gas Valve Redundant Mfr White Rodgers Min inlet pressure In W C 4 5 Natural Gas Max inlet pressure In W C 13 6 Natural Gas Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Direct Drive Motor HP ECM 1 2 3 4 3 4 1 1 Motor Full Load Amps 6 8 8 8 ...

Page 5: ...GAWF1406UFR X X KGAWF1506UFR X Flue Extension KGAFE0112UPH X X X X X Combustible Floor Base KGASB0201ALL X X X X X Downflow Vent Guard KGBVG0101DFG X X X X X Vent Extension Kit KGAVE0101DNH X X X X X Chimney Adapter Kit KGACA02014FC X X X X Chimney Adapter Kit KGACA02015FC X Natural to Propane Conversion Kit KGBNP50011SP X X X X X Propane to Natural Conversion Kit KGBPN42011SP X X X X X Label Kit ...

Page 6: ... Temperature and Humidity Control TP PRH ZONING CONTROL Comfort Series Three Zone Kit ZONECC3ZAC01 ZONECC3ZHP01 2 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC2KIT01 B 4 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC4KIT01 B 8 Performance Series ComfortZone Zoning Temperature and Humidity Control ZONECC8KIT01 B TYPICAL WIRING SCHEMATIC...

Page 7: ...ediately after exiting the furnace except when Downflow Vent Guard is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration 7 Chimney Adapter Kit required for exterior masonry chimney...

Page 8: ... 8 9 SEE NOTES 1 2 4 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL RIGHT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT HORIZONTAL LEFT A02069 A02068 A02070 A02064 A02066 A02065 A02067 58PHA ...

Page 9: ...00 Orange 2 1225 1160 1110 1060 1010 950 895 830 770 710 Red 1 1100 1030 960 875 805 730 645 570 505 425 110 20 Gray 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615 Yellow 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015 Blue 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430 Orange 2 1420 1340 1280 1200 1140 1065 1005 925 865 790 Red 1 1280 1205 1140 1055 990 910 840 760 695 630 135 20 Gr...

Page 10: ... A10269 Always Ask For Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products go to www ahridirectory org 58PHA ...

Page 11: ...ve reusable type filters Filter shall be _______ in x _______in mm An accessory high efficiency Media Filter is available as an option _______________ Media Filter Casing Casing shall be of 030 in 76 mm thickness minimum pre painted steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be ...

Page 12: ...p S 7310 W Morris St S Indianapolis IN 46231 Edition Date 08 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 58PHA 08PD Replaces 58PHA 07PD 58PHA ...

Reviews: