Installation Instructions 

CONTENTS

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1

VERTICAL UNIT INSTALLATION  . . . . . . . . . . . . . . 2

Step 1 — Install Wall Mounting Strip and Hang Base

Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 2 — Make Air Connections   . . . . . . . . . . . . . . 2

Step 3 — Connect Piping  . . . . . . . . . . . . . . . . . . .   3

Step 4 — Install Accessory Grilles (If Supplied,

 on Furred-In or Custom 
Enclosure Installations)  . . . . . . . . . . . . . . . . . .   3

Step 5 — Install Carrier Enclosures   . . . . . . . . . . . 3

Step 6 — Install Stiffener Brackets for Enclosure

Runouts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Step 7 — Install Enclosure and Runout Arrange-

ment As Required  . . . . . . . . . . . . . . . . . . . . . . . . 4

• COLUMN-TO-COLUMN ARRANGEMENT
• COLUMN-TO-COLUMN WITH SHELVING
• ENCLOSURE WITH SINGLE OR DUAL RUNOUT 
• SINGLE OR DUAL RUNOUT WITH KICKSTRIP 

Step 8 — Balance System   . . . . . . . . . . . . . . . . . .   6

HORIZONTAL UNIT INSTALLATION 

(Unit-Mounted or Wall-Mounted 
Thermostat)  . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

Base Unit Not in Carrier Enclosure  . . . . . . . . . . . . 7

Base Unit in Carrier Enclosure   . . . . . . . . . . . . . . . 7

Coil Reversal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

GENERAL

These units are controlled by varying water flow through coil.

Follow installation steps in sequence suggested. Each step in-

cludes figure(s) and procedures required for a specific stage

of installation.
Set up a sample installation to familiarize all trades with their

specific job function.
See  Fig.  1  for  the  Proposition  65  warning  label.  See  Fig.  2

and 3 for 36SV,SL base units.

Fig. 1 — Proposition 65 Warning Label

Fig. 2 — 36SV Base Unit

!

!

!

WARNING

AVERTISSEMENT

ADVERTENCIA

This product can expose you to chemicals
including Acrylonitrile, which is known to the 
State of California to cause cancer. For 
more information, go to 
www.P65Warnings.ca.gov

Ce produit peut vous exposer à des 
agents chimiques, y compris l’acrylonitrile,
que l’État de Californie reconnaît comme
cancérigènes. Pour plus d’informations,
veuillez consulter
www.P65Warnings.ca.gov 

Este producto puede exponerlo a productos
químicos que incluyen acrilonitrilo, que
el estado de California considera que 
causa cáncer. Para más información visite
www.P65Warnings.ca.gov

RETURN

SUPPLY

CONDENSATE
PAN

PRIMARY AIR INLET

36S

Induction Air Terminals

(Bypass and Water Control)

Summary of Contents for INDUCTION AIR TERMINALS 36S

Page 1: ...nclosure 7 Coil Reversal 8 GENERAL These units are controlled by varying water flow through coil Follow installation steps in sequence suggested Each step in cludes figure s and procedures required fo...

Page 2: ...8 Install two No 10 24 bolts factory supplied through two No 10 24 speed nuts provided These or any other suitable means will be used for unit leveling 9 Mark base unit vertical center line on unit 1...

Page 3: ...1 Position recirculation grille mounting frame using holes provided Install recirculation grille panel to grille frame 2 Install discharge grille frame and removable grille sec tions Field fabricated...

Page 4: ...3 16 in holes for attaching runout 2 Cut runout enclosure and enclosure panel to desired length 3 Fit runout enclosure into slots of one end frame 4 Insert enclosure panel into end frame slots 5 Fit s...

Page 5: ...sts on lower flange of end frame 6 Hang assembly on wall mounting strip and adjacent to unit enclosure Stiffener bracket lip must support bottom of runout 7 Attach end frame to unit enclosure with two...

Page 6: ...d adjacent to unit enclosure 5 Attach end frame to unit enclosure with one No 8 sheet metal screw field supplied Step 8 Balance System see Fig 14 1 Remove construction debris from unit Remove protec t...

Page 7: ...ve packing 2 Remove four No 10 16 x 1 2 in screws taped to inside of enclosure end panel 3 Remove Z bars from shipping position fasten to unit with screws and clips provided Install ceiling mounting p...

Page 8: ...S 1SI Carrier Corporation 2018 Coil Reversal see Fig 17 Do not reverse coils having vent fittings except 36SL SM SC ST To reverse coils without vent fittings 1 Remove sheet metal screws fastening cond...

Reviews: