Carrier
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
30
50YCS036 / 38WQS036 With GAH036
Performance capacities shown in thousands of Btuh.
WPD
HEATING - EAT 70
°
F
COOLING - EAT 80/67
°
F
EWT
°
F
GPM
PSI
FT
CFM
HC
KW
HE
LAT
COP
HWC
TC
SC
KW
HR
EER
HWC
4.5
1.6
3.8
975
1200
Operation not recommended
20
7.0
3.3
7.6
975
Operation not recommended
1200
9.0
4.9
11.2
975
23.1
2.15
15.7
91.9
3.14
3.2
1200
22.9
2.23
15.3
87.7
3.01
2.7
4.5
1.6
3.7
975
25.6
2.38
17.5
94.3
3.14
3.6
41.8
27.1
1.32
46.3
31.6
1.2
1200
25.9
2.30
18.1
90.0
3.30
3.0
42.2
29.1
1.38
46.9
30.5
1.1
30
7.0
3.2
7.3
975
26.2
2.31
18.3
94.9
3.32
3.7
41.7
27.3
1.27
46.1
32.9
1.3
1200
26.3
2.31
18.4
90.3
3.33
3.2
42.0
29.4
1.33
46.5
31.7
1.1
9.0
4.7
10.9
975
26.8
2.24
19.2
95.5
3.51
3.9
41.6
27.5
1.22
45.8
34.2
1.3
1200
26.6
2.32
18.7
90.5
3.36
3.3
41.9
29.8
1.27
46.2
32.9
1.2
4.5
1.5
3.5
975
29.2
2.46
20.8
97.7
3.48
4.2
40.4
26.5
1.53
45.6
26.5
2.2
1200
29.6
2.37
21.5
92.8
3.65
3.6
40.7
28.5
1.60
46.1
25.5
2.1
40
7.0
3.1
7.1
975
29.8
2.42
21.6
98.3
3.61
4.4
40.4
26.7
1.47
45.4
27.5
2.1
1200
29.9
2.39
21.8
93.1
3.67
3.7
40.6
28.8
1.54
45.9
26.4
2.0
9.0
4.6
10.6
975
30.4
2.38
22.3
98.9
3.75
4.5
40.4
26.9
1.41
45.2
28.5
1.9
1200
30.3
2.41
22.1
93.4
3.69
3.9
40.6
29.0
1.48
45.6
27.5
1.9
4.5
1.5
3.4
975
32.8
2.53
24.2
101.1
3.80
4.8
38.9
26.0
1.73
44.8
22.5
3.2
1200
33.2
2.44
24.9
95.6
3.99
4.2
39.2
27.9
1.81
45.4
21.7
3.1
50
7.0
3.0
6.9
975
33.4
2.53
24.8
101.7
3.88
5.0
39.0
26.1
1.67
44.7
23.4
2.8
1200
33.6
2.47
25.2
95.9
3.99
4.3
39.3
28.1
1.75
45.2
22.5
2.8
9.0
4.4
10.2
975
34.1
2.52
25.5
102.3
3.96
5.2
39.1
26.2
1.61
44.6
24.3
2.4
1200
34.0
2.49
25.5
96.2
4.00
4.5
39.3
28.3
1.68
45.0
23.4
2.6
4.5
1.4
3.3
975
36.2
2.65
27.2
104.4
4.01
5.5
36.9
25.7
1.90
43.3
19.4
3.9
1200
36.9
2.54
28.2
98.4
4.25
4.7
37.4
28.2
1.98
44.1
18.9
3.9
60
7.0
2.9
6.7
975
36.9
2.65
27.9
105.1
4.08
5.6
37.3
25.9
1.84
43.6
20.3
3.6
1200
37.5
2.57
28.7
98.9
4.28
4.9
37.8
28.2
1.91
44.3
19.8
3.6
9.0
4.3
9.9
975
37.7
2.66
28.6
105.8
4.15
5.8
37.7
26.2
1.78
43.8
21.2
3.2
1200
38.2
2.59
29.3
99.4
4.32
5.1
38.2
28.3
1.85
44.5
20.7
3.3
4.5
1.4
3.2
975
39.6
2.76
30.2
107.6
4.20
6.1
34.8
25.4
2.07
41.9
16.8
4.7
1200
40.5
2.64
31.5
101.3
4.49
5.3
35.5
28.4
2.15
42.8
16.5
4.7
70
7.0
2.8
6.5
975
40.5
2.78
31.0
108.4
4.26
6.3
35.6
25.8
2.01
42.4
17.7
4.3
1200
41.4
2.67
32.3
101.9
4.55
5.5
36.3
28.3
2.08
43.4
17.5
4.4
9.0
4.1
9.6
975
41.3
2.80
31.7
109.2
4.32
6.5
36.3
26.2
1.96
43.0
18.6
3.9
1200
42.3
2.69
33.1
102.6
4.61
5.7
37.1
28.2
2.01
44.0
18.5
4.1
4.5
1.3
3.1
975
43.2
2.86
33.4
111.0
4.42
6.8
33.5
24.5
2.30
41.4
14.6
5.4
1200
44.2
2.74
34.8
104.1
4.72
5.8
34.2
27.4
2.39
42.3
14.3
5.5
80
7.0
2.7
6.2
975
44.0
2.88
34.2
111.8
4.47
7.0
34.3
24.9
2.23
41.9
15.4
5.0
1200
45.0
2.76
35.6
104.7
4.78
6.1
35.0
27.3
2.31
42.9
15.2
5.1
9.0
4.0
9.3
975
44.8
2.90
34.9
112.6
4.53
7.3
35.0
25.2
2.17
42.4
16.1
4.6
1200
45.9
2.79
36.4
105.4
4.83
6.3
35.8
27.2
2.23
43.4
16.0
4.8
4.5
1.3
3.0
975
46.7
2.97
36.6
114.4
4.61
7.5
32.3
23.6
2.52
40.9
12.8
6.1
1200
47.8
2.84
38.1
106.9
4.93
6.3
32.9
26.4
2.62
41.9
12.6
6.3
90
7.0
2.6
6.0
975
47.5
2.98
37.4
115.1
4.67
7.8
33.0
24.0
2.45
41.4
13.4
5.7
1200
48.7
2.86
38.9
107.5
4.98
6.6
33.7
26.3
2.54
42.3
13.3
5.9
9.0
3.9
8.9
975
48.3
3.00
38.1
115.9
4.72
8.1
33.7
24.3
2.38
41.8
14.1
5.4
1200
49.5
2.88
39.7
108.2
5.04
6.9
34.4
26.2
2.45
42.8
14.0
5.5
4.5
1.3
2.9
975
30.3
23.7
2.83
39.9
10.7
6.9
1200
30.9
26.5
2.94
40.9
10.5
7.2
100
7.0
2.5
5.8
975
30.9
24.1
2.75
40.3
11.2
6.5
1200
31.6
26.4
2.85
41.3
11.1
6.7
9.0
3.7
8.6
975
31.6
24.4
2.67
40.7
11.8
6.1
1200
Operation not recommended
32.3
26.3
2.75
41.6
11.7
6.2
4.5
1.2
2.8
975
28.2
23.9
3.14
38.9
9.0
7.7
1200
28.8
26.7
3.26
39.9
8.8
8.0
110
7.0
2.4
5.6
975
28.9
24.2
3.05
39.3
9.5
7.2
1200
29.5
26.6
3.16
40.2
9.3
7.5
9.0
3.6
8.3
975
29.5
24.6
2.97
39.6
9.9
6.8
1200
30.1
26.5
3.05
40.5
9.9
7.0
Rev: 12/12/03 B
Operation below 40
°
F EWT is based on 15% antifreeze solution.
See performance correction tables for operating conditions other than those listed above.
Table does not reflect fan or pump power ISO corrections.
Performance capacities shown in thousands of Btuh.
All entering air conditions are 80
°
F DB and 67
°
F WB in cooling and 70
°
F DB in heating.
All performance data is based upon the lower voltage of dual voltage rated units.