![Carrier GT-PX User Manual Download Page 31](http://html.mh-extra.com/html/carrier/gt-px/gt-px_user-manual_2563544031.webp)
Indoor & Outdoor Split
Geothermal Comfort Systems
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
29
50YCS030 / 38WQS030 With GAH030
Performance capacities shown in thousands of Btuh.
WPD
HEATING - EAT 70
°
F
COOLING - EAT 80/67
°
F
EWT
°
F
GPM
PSI
FT
CFM
HC
KW
HE
LAT
COP
HWC
TC
SC
KW
HR
EER
HWC
3.7
0.6
1.5
800
1000
Operation not recommended
20
5.5
1.4
3.3
800
Operation not recommended
1000
7.5
2.7
6.2
800
18.4
1.92
11.9
91.3
2.82
2.6
1000
18.6
1.88
12.2
87.2
2.91
2.2
3.7
0.6
1.4
800
20.6
1.97
13.9
93.8
3.06
2.9
34.5
22.6
1.09
38.2
31.6
1.1
1000
20.7
1.92
14.1
89.1
3.15
2.5
36.0
25.2
1.04
39.5
34.4
0.9
30
5.5
1.4
3.2
800
21.5
1.96
14.8
94.9
3.20
3.0
34.6
22.4
1.07
38.3
32.4
1.1
1000
21.6
1.92
15.1
90.0
3.30
2.6
36.0
24.7
1.09
39.7
33.1
1.0
7.5
2.6
6.0
800
22.4
1.96
15.7
95.9
3.35
3.2
34.8
22.2
1.05
38.4
33.2
1.2
1000
22.6
1.92
16.1
90.9
3.45
2.7
36.1
24.1
1.14
40.0
31.8
1.0
3.7
0.6
1.4
800
24.0
2.03
17.1
97.8
3.48
3.4
33.5
22.3
1.31
37.9
25.5
1.9
1000
24.1
1.98
17.4
92.4
3.58
3.0
34.9
25.0
1.25
39.2
27.8
1.8
40
5.5
1.3
3.1
800
24.9
2.04
18.0
98.9
3.58
3.6
33.6
22.2
1.26
37.9
26.7
1.8
1000
24.9
1.98
18.2
93.1
3.68
3.1
34.9
24.4
1.28
39.3
27.3
1.7
7.5
2.5
5.8
800
25.8
2.06
18.8
99.9
3.68
3.7
33.7
22.1
1.20
37.8
28.0
1.6
1000
25.7
1.99
18.9
93.8
3.78
3.2
35.0
23.9
1.31
39.5
26.8
1.6
3.7
0.6
1.3
800
27.5
2.08
20.4
101.8
3.87
4.0
32.4
22.1
1.53
37.7
21.2
2.7
1000
27.6
2.03
20.7
95.6
3.99
3.4
33.8
24.7
1.47
38.8
23.1
2.6
50
5.5
1.3
3.0
800
28.4
2.12
21.2
102.8
3.93
4.1
32.6
22.0
1.45
37.5
22.5
2.4
1000
28.2
2.05
21.2
96.1
4.04
3.6
33.9
24.2
1.47
38.9
23.0
2.4
7.5
2.4
5.6
800
29.3
2.16
21.9
103.9
3.98
4.2
32.7
21.9
1.36
37.3
24.0
2.1
1000
28.8
2.06
21.8
96.6
4.09
3.7
33.9
23.8
1.48
39.0
23.0
2.2
3.7
0.6
1.3
800
31.0
2.17
23.6
105.8
4.19
4.5
31.2
21.4
1.66
36.9
18.8
3.3
1000
31.1
2.09
24.0
98.8
4.37
3.9
32.7
23.8
1.67
38.3
19.6
3.3
60
5.5
1.3
2.9
800
31.8
2.21
24.3
106.8
4.22
4.6
31.2
21.1
1.59
36.7
19.7
3.0
1000
32.0
2.11
24.8
99.6
4.45
4.1
32.7
23.5
1.62
38.3
20.2
3.0
7.5
2.4
5.4
800
32.7
2.25
25.0
107.9
4.25
4.8
31.2
20.8
1.52
36.4
20.6
2.7
1000
32.9
2.13
25.6
100.4
4.52
4.2
32.8
23.1
1.58
38.2
20.7
2.8
3.7
0.5
1.3
800
34.4
2.25
26.8
109.9
4.48
5.0
30.0
20.7
1.79
36.2
16.8
3.9
1000
34.6
2.14
27.3
102.0
4.73
4.4
31.5
23.0
1.87
37.9
16.9
3.9
70
5.5
1.2
2.8
800
35.3
2.30
27.4
110.8
4.50
5.2
29.9
20.2
1.73
35.8
17.3
3.6
1000
35.8
2.17
28.4
103.1
4.83
4.5
31.6
22.8
1.78
37.7
17.8
3.7
7.5
2.3
5.3
800
36.1
2.35
28.1
111.8
4.51
5.3
29.7
19.7
1.67
35.5
17.8
3.3
1000
37.0
2.20
29.5
104.2
4.92
4.7
31.7
22.5
1.69
37.5
18.8
3.4
3.7
0.5
1.2
800
37.9
2.31
30.0
113.9
4.81
5.6
29.0
20.7
2.00
35.9
14.5
4.5
1000
38.0
2.20
30.5
105.2
5.08
4.8
30.5
23.0
2.08
37.6
14.7
4.6
80
5.5
1.2
2.7
800
38.6
2.37
30.5
114.7
4.77
5.8
28.9
20.2
1.93
35.5
15.0
4.2
1000
39.1
2.24
31.5
106.2
5.12
5.0
30.6
22.7
1.98
37.3
15.4
4.3
7.5
2.2
5.1
800
39.3
2.44
31.0
115.5
4.73
6.0
28.7
19.7
1.87
35.1
15.4
3.9
1000
40.2
2.28
32.4
107.2
5.17
5.2
30.6
22.5
1.89
37.1
16.3
4.0
3.7
0.5
1.2
800
41.4
2.37
33.3
117.9
5.12
6.2
28.0
20.7
2.20
35.5
12.7
5.1
1000
41.5
2.25
33.8
108.4
5.41
5.2
29.4
23.0
2.30
37.3
12.8
5.3
90
5.5
1.1
2.6
800
41.9
2.44
33.6
118.5
5.03
6.4
27.9
20.2
2.13
35.2
13.1
4.8
1000
42.5
2.31
34.6
109.3
5.40
5.5
29.5
22.7
2.19
37.0
13.5
4.9
7.5
2.1
4.9
800
42.5
2.52
33.9
119.2
4.94
6.7
27.7
19.7
2.06
34.8
13.5
4.5
1000
43.5
2.36
35.4
110.3
5.40
5.7
29.6
22.5
2.08
36.7
14.2
4.6
3.7
0.5
1.1
800
26.4
19.6
2.39
34.6
11.0
5.8
1000
27.7
21.8
2.49
36.2
11.1
6.0
100
5.5
1.1
2.5
800
26.3
19.2
2.32
34.2
11.4
5.4
1000
27.8
21.6
2.38
35.9
11.7
5.6
7.5
2.0
4.7
800
26.2
18.7
2.24
33.8
11.7
5.1
1000
Operation not recommended
27.9
21.3
2.26
35.6
12.3
5.2
3.7
0.5
1.1
800
24.8
18.6
2.58
33.6
9.6
6.4
1000
26.0
20.6
2.69
35.2
9.7
6.7
110
5.5
1.1
2.4
800
24.7
18.1
2.50
33.2
9.9
6.0
1000
26.1
20.4
2.57
34.9
10.2
6.2
7.5
2.0
4.5
800
24.6
17.7
2.42
32.8
10.2
5.7
1000
26.2
20.2
2.44
34.5
10.7
5.8
Rev: 12/12/03 B
Operation below 40
°
F EWT is based on 15% antifreeze solution.
See performance correction tables for operating conditions other than those listed above.
Table does not reflect fan or pump power ISO corrections.
Interpolation is permissable, extrapolation is not.
All entering air conditions are 80
°
F DB and 67
°
F WB in cooling and 70
°
F DB in heating.
All performance data is based upon the lower voltage of dual voltage rated units.