FB4C

FY5B

Installation Instructions

FAN COIL UNITS

FOR PURON

r

REFRIGERANT

SIZES 018 TO 060

NOTE

: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HEATER PACKAGES

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Check Equipment

2

. . . . . . . . . . . . . . . . . . . . . . . . .

Step 2 — Mount Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Air Ducts

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 4 — Electrical Connections

4

. . . . . . . . . . . . . . . . . . . . .

Step 5 — Refrigerant Tubing Connection and Evacuation

7

. .

Step 6 — Refrigerant Flow--Control Device

7

. . . . . . . . . . . . .

Step 7 — Condensate Drains

8

. . . . . . . . . . . . . . . . . . . . . . . .

Step 8 — Accessories

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 9 — Sequence of Operation

10

. . . . . . . . . . . . . . . . . . . .

START--UP PROCEDURES

10

. . . . . . . . . . . . . . . . . . . . . . . . .

CARE AND MAINTENANCE

10

. . . . . . . . . . . . . . . . . . . . . . .

AIRFLOW PERFORMANCE TABLES

11

. . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit. Consult local
building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instruction manuals,

be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies hazards

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which will result in enhanced installation, reliability, or

operation.

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing unit, always turn off all power to

unit. There may be more than 1 disconnect switch. Turn off

accessory heater power if applicable. Lock out and tag switch

with a suitable warning label.

!

WARNING

CUT HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

CAUTION

!

INTRODUCTION

Models FB4C and FY5B are Puron Fan Coils designed for

installation flexibility. These units are designed to meet the low air
leak requirements currently in effect.
FB4C uses a refrigerant piston metering device (018 thru 048) and
TXV (060) with an X13 integral electronically commutated motor

for efficiency. These units have be designed for upflow, downflow
(kit required), and horizontal orientations, including manufactured

and mobile home applications.
FY5B uses a refrigerant piston metering device (018 thru 048) with
2--speed PSC (permanent split capacitor) motors and TXV with

3--speed PSC motor for the 060 size, These units can be used for
upflow or downflow (kit required)

orientations, including

manufactured and mobile homes applications.
These units require a field supplied air filter, and are designed
specifically for Puron refrigerant air conditioners and heat pumps

as shipped. These units are available for systems of 18,000 through
60,000 Btuh nominal cooling capacity. Factory--authorized, field --

installed electric heater packages are available in sizes 5 through

30kW. See Product Data literature for all available accessory kits.

Summary of Contents for fb4c

Page 1: ...ost serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation ELECTRICAL OPERATION HAZARD Fa...

Page 2: ...E A07565 Fig 1 Slope Coil Unit in Upflow Application B Downflow Installation In this application field conversion of the evaporator is required using accessory downflow kit along with an accessory base kit Use fireproof resilient gasket 1 8 to 1 4 in 3 to 6 mm thick between duct unit and floor UNIT OR PROPERTY DAMAGE HAZARD Failure to follow this caution may result in product or property damage Th...

Page 3: ...er kit instructions 8 Align holes with tubing connections and condensate pan connections and reinstall access panels and fitting panel Make sure liquid and suction tube grommets are in place to prevent air leaks and cabinet sweating Install after brazing COIL MOUNTING SCREW BLOWER ASSEMBLY REFRIGERANT CONNECTIONS SECONDARY DRAIN PRIMARY DRAIN DRAINPAN SLOPE COIL SKI COIL SUPPORT RAIL A03001 Fig 5 ...

Page 4: ...3 mm thick right angle brackets Attach brackets to fan coil using no 10 self tapping screws and to wall stud using 5 16 in lag screws See Fig 8 Step 3 Air Ducts Connect supply air duct over the outside of 3 4 in 19 mm flanges provided on supply air opening Secure duct to flange using proper fasteners for type of duct used and seal duct to unit joint If return air flanges are required install facto...

Page 5: ...ard power plug from fan coil and connect male plug from heater to female plug from unit wiring harness See Electric Heater Installation Instructions For units without electric heater 1 Connect 208 230v power leads from field disconnect to yel low and black stripped leads 2 Connect ground wire to unit ground lug NOTE Units installed without electric heat should have a field supplied sheet metal blo...

Page 6: ... this caution may result in product or property damage If W2 W3 and E on any 3 stage heater 18 20 24 or 30kW are individually connected as with outdoor thermostats or any other situation emergency heat relay must be used This relay is in kit Part No KHOT0201SEC and is normally used with kit Part No KHAOT0301FST for 2 outdoor thermostat systems CAUTION The controls are factory circuited for single ...

Page 7: ...ctory default position and move to desired speed tap 1 2 3 or 5 Speed taps 1 2 and 3 have a 90 second blower time delay pre programmed into the motor Speed tap 4 is used for electric heat only with 0 second blower time delay and the WHITE wire must remain on tap 4 Speed tap 5 is used for high static applications but has a 0 second blower time delay pre programmed into the motor see Table 1 FB4C Ai...

Page 8: ...y exit the fitting to retain the low leak rating of the unit UNIT OR PROPERTY DAMAGE HAZARD Failure to follow this caution may result in product or property damage The conversion of the fan coil to downflow requires special procedures for the condensate drains on both A coil and slope units The vertical drains have an overflow hole between the primary and secondary drain holes This hole is plugged...

Page 9: ...sate will be noticeable The owner of the structure must be informed that when condensate flows from the secondary drain or external condensate pan the unit requires servicing or water damage will occur Install traps in the condensate lines as close to the coil as possible See Fig 21 Make sure that the outlet of each trap is below its connection to the condensate pan to prevent condensate from over...

Page 10: ... electric heat relay s open turning off heater elements When G is de energized there is a 90 sec delay before fan relay opens D Electric Heat or Emergency Heat Mode Thermostat closes R to W W energizes electric heat relay s which completes circuit to heater element s Blower motor is energized through normally closed contacts on fan relay When W is de energized electric heat relay s opens START UP ...

Reviews: