background image

FY4A, FA4C

Base Series Fan Coil

Sizes 1 1/2 — 5 Ton (018 Thru 060)

Product Data

AIR HANDLER TECHNOLOGY

AT ITS FINEST

The FY4A and FA4C direct--expansion fan coils are designed to

cover a wide range of air handling requirements. They are compact
and ready to fit where needed, in the basement, crawlspace, attic,

utility room, or closet. The unique cabinet design of these fan coils
meet new stringent regulations for cabinet air leakage, a

requirement of 2% cabinet leakage rate when tested at 1.0 inches of

static pressure.
The FY4A and FA4C units are shipped with a factory--installed

hard--shutoff thermostatic expansion valve (TXV) metering device
with an internal check valve for reverse flow bi--pass capability. All

units come with solid state fan controls, 1--in. thick insulation with

R--value of 4.2, super--quiet multispeed motors, and fully--wettable
coils. Units can accommodate factory-- or field--installed heaters

from 3 to 30 kW.
The FY4A design is a residential new construction (RNC) model

available for use with Puron

r

, the environmentally sound

refrigerant. It comes with or without factory--installed disconnects.

It has a pre--painted (gray) galvanized insulated steel casing,

2--speed PSC motor in the 018 through 036 sizes, and 3--speed
PSC motors in the 042 through 060 sizes. ArmorCoat

t

provides a

tin plating of the indoor coil’s copper hairpins. This creates a
barrier between the corrosion--causing elements and the coil.
The FA4C has all the same quality features as the FY4A, but is for

use with R--22 refrigerant.

Summary of Contents for FA4C series

Page 1: ...al check valve for reverse flow bi pass capability All units come with solid state fan controls 1 in thick insulation with R value of 4 2 super quiet multispeed motors and fully wettable coils Units c...

Page 2: ...speed motor in 042 through 060 sizes S Cooling controls S Time delay relay TDR S Pre painted galvanized steel cabinet gray S High density super thick R 4 2 insulation S Newly improved filter rack area...

Page 3: ...uronr Refrigerant 4 Multipoise C N 208 230v 1ph 60Hz B Modular C Factory Disconnects F Single piece 018 18 000 024 24 000 030 30 000 036 36 000 042 42 000 048 48 000 060 60 000 T00 ArmorCoatt 000 No H...

Page 4: ...12 7 16 316 12 5 16 313 10 7 16 265 12 305 024 030 Slope 47 11 16 1211 5 17 5 8 448 15 3 4 400 15 5 8 397 15 3 8 391 17 432 036 Slope 53 7 16 1357 21 1 8 537 19 1 4 489 19 1 8 486 19 3 16 487 19 483 0...

Page 5: ...FY FA COIL TYPE F G in mm in mm 018 Slope 18 1 8 460 18 5 8 473 024 030 Slope 23 1 8 587 23 5 8 600 036 Slope 26 15 16 684 27 1 2 699 042 A 23 7 16 593 23 1 8 587 048 A 27 1 4 692 26 15 16 684 060 A...

Page 6: ...lar cabinet C Disconnect F Single piece cabinet 10th digit 0 Standard copper coil T ArmorCoatt ODS CATALOG ORDERING NO FACTORY INSTALLED HEAT kW NOMINAL COOLING CAPACITY BTUH DIMENSIONS SHIPPING WEIGH...

Page 7: ...lied for FA4C units PERFORMANCE DATA AIRFLOW PERFORMANCE CFM MODEL SIZE BLOWER SPEED TOTAL EXTERNAL STATIC PRESSURE 0 10 0 20 0 30 0 40 0 50 0 60 FY4A FA4C 018 High 816 795 753 690 607 504 Low 633 620...

Page 8: ...2 0 04 38 28 0 04 28 23 0 05 62 17 52 41 0 05 44 37 0 05 36 33 0 05 28 28 0 11 24 24 0 26 1200 72 22 87 43 0 00 78 39 0 00 68 34 0 03 57 30 0 04 46 25 0 05 67 19 72 44 0 05 63 40 0 05 53 35 0 06 42 31...

Page 9: ...30 0 04 34 26 0 04 24 21 0 06 62 17 48 39 0 05 40 35 0 05 32 31 0 06 26 26 0 16 22 22 0 31 1200 72 22 79 39 0 00 71 35 0 03 62 31 0 04 52 27 0 05 41 23 0 05 67 19 65 41 0 05 57 37 0 05 48 33 0 06 38 2...

Page 10: ...970 970 920 1040 042 1225 1225 1225 1225 1225 1225 048 1400 1400 1400 1400 1400 1400 1400 1400 060 1750 1750 1750 1750 1750 1750 1750 1750 Indicates medium speed blue All other motor speeds at low ta...

Page 11: ...57 4 55 4 53 4 49 4 048 1600 0 25 69 0 65 0 61 0 58 0 56 0 54 0 50 0 060 2000 0 25 70 0 66 0 62 0 59 0 57 0 55 0 51 0 Est sound power levels have been derived using the method described in the 1987 A...

Page 12: ...55 4 60 60 18 1 20 0 22 6 25 0 25 25 NOTE All units 208 230 single phase 60 Hz MCA Minimum Circuit Amps FLA Full Load Amps ELECTRICAL DATA FOR UNITS WITHOUT FACTORY INSTALLED HEATERS MODEL NO MTR HP...

Page 13: ...None 37 6 41 5 55 5 60 4 6 6 10 8 60 70 76 77 KFCEH3201F20 20 15 0 1 Fuse 72 3 79 9 36 2 40 0 36 2 40 0 98 9 108 4 53 8 58 5 45 3 50 0 3 2 6 6 8 8 8 6 10 10 10 10 100 110 60 60 50 50 85 109 78 80 59 5...

Page 14: ...are used in downflow applications 4 Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs and between the L2 and L4 lugs This allows the installer to run two heav...