6
UNIT
48/50P
FAN ARRANGEMENT
FAN NO.
NORMAL CONTROL
030,035
1
MMV-A
2
Controlled by the
Comfort
Link™ head pressure
control routine
040
1
Controlled by the
Comfort
Link head pressure
control routine
2
3
MMV-A
050-060
1
MMV-A
2
Controlled by the
Comfort
Link head pressure
control routine
3
4
070,075
1
MMV-B
2
Controlled by the
Comfort
Link head pressure
control routine
3
MMV-A
4
Controlled by the
Comfort
Link head pressure
control routine
090,100
1
Controlled by the
Comfort
Link head pressure
control routine
2
MMV-B
3
Controlled by the
Comfort
Link head pressure
control routine
4
5
6
MMV-A
C
ont
rol Box
1
2
C
ont
rol Box
1
2
3
C
ont
rol Box
1
2
4
3
C
ont
rol Box
1
2
4
3
C
ont
rol Box
1
2
4
6
5
3
Fig. 3 — Fan Control
REMOVE PANEL
RUN ELECTRICAL HARNE
SS
E
S
UP THE
S
IDE
OF THE UNIT IN THE
S
PACE BETWEEN THE
CORNER PO
S
T AND THE CONTROL BOX.
ROUTE THE WIRING INTO THE WIRE TRAY,
THEN RUN APPROPRIATE WIRE
S
TO OFM 1
AND MOTORMA
S
TER CONTROL
MOTORMA
S
TER
CONTROL
TRAN
S
DUCER
HARNE
SS
FROM
CIRCUIT A LIQUID LINE
TRAN
S
DUCER TO MMV
Fig. 4 — MMV Control Mounting — 48/50P030,035 Units
a48-8562