Series Fan Coil

Sizes 019 thru 061

Product Data

A10009

AIR HANDLER TECHNOLOGY

AT ITS FINEST

The FX4D fan coils combine the proven technology of Carrier fan

coil units with Puron

®

, the environmentally sound refrigerant.

These fan coils are loaded with popular features. Factory--installed,
refrigerant--specific thermostatic expansion valves (TXV) are

standard with these fan coil designs. The designs feature contoured
condensate pans with rugged, drain connections, ensuring that little

water is left in the unit at the end of the cooling duty cycle. The

lack of standing condensate and corrosion free pans improves IAQ
and product life, features homeowners appreciate.
Standard features include grooved copper tubing and louvered
aluminum fins. The large face areas of the refrigerant coils provide

superior efficiency for high SEER and HSPF performance. Coil

circuiting has also been updated to make the most of all Carrier
heat pumps and air conditioners. Also units come with solid state

fan controls, 1--in (25mm) thick insulation with R--value of 4.2,
multi--speed motors, and fully--wettable coils. Units can

accommodate factory-- and/or field--installed heaters from 3 to 30
kW.
It also should be noted that the unique cabinet design of these fan

coils meet new stringent regulations for cabinet air leakage -- a
requirement of 2% cabinet leakage rate when tested at 1.0 inches of

static pressure.
The FX4D fan coil is the Puron

®

refrigeration design loaded with

popular features. It comes in a pre--painted (taupe metallic)

galvanized steel casing and is shipped with a cleanable, permanent
framed filter, and a factory--supplied power plug. ArmorCoat

t

provides a tin plating of the indoor coil’s copper hairpins. This
creates a barrier between the corrosion--causing elements and the

coil. These fan coils utilize the latest in electronic commutation

motor (ECM) technology through the use of high efficiency, X13,
blower motors.

Summary of Contents for Comfort FX4DNF019

Page 1: ...nce Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners Also units come with solid state fan controls 1 in 25mm thick insulation with R value of 4 2 m...

Page 2: ...Horizontal hanging provisions on cabinet S No tools required to service filter S Factory supplied cleanable and reusable filter S Newly improved filter rack area filter door insulation added for impro...

Page 3: ...ph 60 Hz 010 10kW 015 15kW Cabinet Style B Modular Coil Coating F Single Piece 0 Standard T ArmorCoatt Capacity 019 18 000 025 24 000 031 30 000 037 36 000 043 42 000 049 48 000 061 60 000 the environ...

Page 4: ...13 16 2 1 8 1 1 4 A FOR MODULAR UNITS 1 3 16 MAX 7 8 11 1 3 4 19 NOTE MODULAR UNITS WILL HAVE A TWO PIECE CABINET RIGHT SIDE VIEW OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING SLOPE COIL UNITS O...

Page 5: ...G F AIRFLOW SECONDARY DRAIN PRIMARY DRAIN DOWNFLOW FIELD CONVERTED 1 13 16 TYP 5 16 TYP 1 5 8 5 16 TYP 7 8 TYP 2 7 8 5 1 1 4 1 2 TYP SECONDARY DRAIN PRIMARY DRAIN HORIZ LEFT AS SHIPPED 1 13 16 TYP 5 1...

Page 6: ...560 4 OPENING 503 2 54 0 31 8 A FOR MODULAR UNITS 30 2 MAX 22 2 279 4 44 4 482 6 NOTE MODULAR UNITS WILL HAVE A TWO PIECE CABINET RIGHT SIDE VIEW OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING SL...

Page 7: ...0 TYP 8 0 TYP 22 2 TYP 73 0 127 0 31 8 12 7 TYP SECONDARY DRAIN PRIMARY DRAIN HORIZ LEFT AS SHIPPED 82 6 65 1 73 0 55 6 TYP 2 PLACES 11 1 TYP 2 PLACES 25 4 TYP 2 PLACES 31 8 AIRFLOW SECONDARY DRAIN P...

Page 8: ...15 FX4DNB031T00 30 000 53 7 16 in 1357mm 21 1 8 in 536mm 22 1 16 in 560mm 146 lb 66 kg FX4DNB037T00 36 000 53 7 16 in 1357mm 21 1 8 in 536mm 22 1 16 in 560mm 175 lb 79kg FX4DNB043T00 42 000 53 7 16 in...

Page 9: ...1206 1160 1121 1070 1013 FX4D 049 Tap 5 1757 1725 1693 1653 1614 1576 Tap 4 1664 1626 1593 1552 1517 1477 Tap 3 1664 1626 1593 1552 1517 1477 Tap 2 1459 1420 1379 1336 1298 1259 Tap 1 1301 1241 1195 1...

Page 10: ...33 0 03 40 29 0 03 31 25 0 03 22 20 0 04 62 17 43 37 0 03 36 33 0 03 29 29 0 04 22 22 0 10 18 18 0 26 1200 72 22 74 40 0 00 66 36 0 00 58 31 0 01 48 27 0 03 38 22 0 04 67 19 60 41 0 04 52 36 0 04 44 3...

Page 11: ...ERATURE _F 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 ENTERING AIR DRY BULB TEMPERATURE _C 26 25 25 24 24 Under 75 27 28 28 29 29 Over 85 Correction Factor 0 10 098 1 96 2 94 3 92 4 91 Use formula...

Page 12: ...ne 018 060 31 400 KFCEH3201F20 20 230 1 5 20 Fuse 030 060 62 800 KFCEH1601315 15 230 3 5 15 None 036 060 47 100 KFCEH2001318 18 230 3 6 12 18 None 042 060 56 500 KFCEH3401F24 24 230 3 8 16 24 Fuse 048...

Page 13: ...5 25 MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection ELECTRICAL DATA FOR UNITS WITHOUT ELECTRICAL HEAT MODEL NO MTR HP MTR FLA VOLTS PH HZ SINGLE CIRCUIT BRANCH CIRCUIT MIN WIRE SIZE AWG...

Page 14: ...3 None 37 6 41 5 55 5 60 4 6 6 10 8 60 70 76 77 KFCEH3201F20 20 15 0 1 Fuse 72 3 79 9 36 2 40 0 36 2 40 0 98 9 108 4 53 8 58 5 45 3 50 0 3 2 6 6 8 8 8 6 10 10 10 10 100 110 60 60 50 50 85 109 78 80 5...

Page 15: ...space must be insulated and covered with vapor barrier ACCESSORIES ITEM ACCESSORY PART NO FAN COIL SIZE USED WITH 1 Disconnect Kit KFADK0201DSC Cooling controls and heaters 3 through 10 kW 2 Downflow...

Page 16: ...4 light gauge high voltage wires SUGGESTED USE Fan coils with 15 and 20 kW fused heaters only 7 Filter Kit 12 pack The kit consists of 12 fan coil framed filters These filters collect large dust parti...

Reviews: