background image

8

PHYSICAL DATA

ORDERING NO.

FACTORY

INSTALLED

HEAT (kW)

NOMINAL COOLING

CAPACITY (Btuh)

DIMENSIONS

SHIPPING

WEIGHT

Height

Width

Depth

FX4DNF0190,T)00

---

18,000

49 5/8---in

1261mm

17 5/8---in

447mm

22---1/16---in

560mm

122 lb

55 kg

FX4DNF019005

5

FX4DNF025(0,T)00

---

24,000

49 5/8---in

1261mm

17 5/8---in

447mm

22---1/16---in

560mm

122 lb

55 kg

FX4DNF025005

5

FX4DNF031(0,T)00

---

30,000

53 7/16---in

1357mm

21 1/8---in

536mm

22---1/16---in

560mm

146 lb

66 kg

FX4DNF031008

8

FX4DNF037(0,T)00

---

36,000

49 5/8---in

1261mm

21 1/8---in

536mm

22---1/16---in

560mm

157 lb

71 kg

FX4DNF037010

10

FX4DNF043(0,T)00

---

42,000

49 5/8---in

1260mm

21 1/8---in

536mm

22---1/16---in

560mm

157 lb

71 kg

FX4DNF043010

10

FX4DNF049(0,T)00

---

48,000

53 7/16---in

1357mm

24 11/16---in

627mm

22---1/16---in

560mm

185 lb

84 kg

FX4DNF049010

10

FX4DNF061(0,T)00

---

60,000

59 3/16---in

1503mm

24 11/16---in

627mm

22---1/16---in

560mm

201 lb

91 kg

FX4DNF061010

10

FX4DNF061015

15

FX4DNB031T00

---

30,000

53 7/16---in

1357mm

21 1/8---in

536mm

22---1/16---in

560mm

146 lb

66 kg

FX4DNB037T00

---

36,000

53 7/16---in

1357mm

21 1/8---in

536mm

22---1/16---in

560mm

175 lb

79kg

FX4DNB043T00

---

42,000

53 7/16---in

1357mm

21 1/8---in

536mm

22---1/16---in

560mm

175 lb

79kg

FX4DNB049T00

---

48,000

53 7/16---in

1357mm

24 11/16---in

627mm

22---1/16---in

560mm

185 lb

84 kg

FX4DNB061T00

---

60,000

59 3/16---in

1503mm

24 11/16---in

627mm

22---1/16---in

560mm

201 lb

91 kg

6th digit: B --- Modular cabinet, F --- Single piece cabinet
10th digit: 0 --- Standard copper coil, T --- ArmorCoat

t

SPECIFICATIONS

MODEL FX4D

019

025

031

037

043

049

061

COIL

Puron

r

Refrigerant

Metering Device

TXV --- factory installed hard---shutoff, bi---flow type for heat pump application

TXV

2 ton

3 ton

4 ton

Rows/Fins Per In.

3 / 14.5

Face Area (Sq. Ft.)

2.97

3.46

4.45

5.93

7.42

Configuration

Slope

A

FAN

CFM (Nominal)

600

800

1000

1200

1400

1600

2000

Motor Type (ECM)

X---13

X---13

X---13

X---13

X---13

X---13

X---13

Motor Hp

1/3

1/3

1/2

1/2

1/2

3/4

3/4

FILTER

21---1/2---in / 546 mm X

16---3/8---in / 417 mm

19---7/8---in / 505 mm

23---5/16---in / 585 mm

CABINET CONFIGURATION OPTIONS

1---pc

1---pc / Modular

FX4

D

Summary of Contents for Comfort FX4DNF019

Page 1: ...nce Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners Also units come with solid state fan controls 1 in 25mm thick insulation with R value of 4 2 m...

Page 2: ...Horizontal hanging provisions on cabinet S No tools required to service filter S Factory supplied cleanable and reusable filter S Newly improved filter rack area filter door insulation added for impro...

Page 3: ...ph 60 Hz 010 10kW 015 15kW Cabinet Style B Modular Coil Coating F Single Piece 0 Standard T ArmorCoatt Capacity 019 18 000 025 24 000 031 30 000 037 36 000 043 42 000 049 48 000 061 60 000 the environ...

Page 4: ...13 16 2 1 8 1 1 4 A FOR MODULAR UNITS 1 3 16 MAX 7 8 11 1 3 4 19 NOTE MODULAR UNITS WILL HAVE A TWO PIECE CABINET RIGHT SIDE VIEW OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING SLOPE COIL UNITS O...

Page 5: ...G F AIRFLOW SECONDARY DRAIN PRIMARY DRAIN DOWNFLOW FIELD CONVERTED 1 13 16 TYP 5 16 TYP 1 5 8 5 16 TYP 7 8 TYP 2 7 8 5 1 1 4 1 2 TYP SECONDARY DRAIN PRIMARY DRAIN HORIZ LEFT AS SHIPPED 1 13 16 TYP 5 1...

Page 6: ...560 4 OPENING 503 2 54 0 31 8 A FOR MODULAR UNITS 30 2 MAX 22 2 279 4 44 4 482 6 NOTE MODULAR UNITS WILL HAVE A TWO PIECE CABINET RIGHT SIDE VIEW OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING SL...

Page 7: ...0 TYP 8 0 TYP 22 2 TYP 73 0 127 0 31 8 12 7 TYP SECONDARY DRAIN PRIMARY DRAIN HORIZ LEFT AS SHIPPED 82 6 65 1 73 0 55 6 TYP 2 PLACES 11 1 TYP 2 PLACES 25 4 TYP 2 PLACES 31 8 AIRFLOW SECONDARY DRAIN P...

Page 8: ...15 FX4DNB031T00 30 000 53 7 16 in 1357mm 21 1 8 in 536mm 22 1 16 in 560mm 146 lb 66 kg FX4DNB037T00 36 000 53 7 16 in 1357mm 21 1 8 in 536mm 22 1 16 in 560mm 175 lb 79kg FX4DNB043T00 42 000 53 7 16 in...

Page 9: ...1206 1160 1121 1070 1013 FX4D 049 Tap 5 1757 1725 1693 1653 1614 1576 Tap 4 1664 1626 1593 1552 1517 1477 Tap 3 1664 1626 1593 1552 1517 1477 Tap 2 1459 1420 1379 1336 1298 1259 Tap 1 1301 1241 1195 1...

Page 10: ...33 0 03 40 29 0 03 31 25 0 03 22 20 0 04 62 17 43 37 0 03 36 33 0 03 29 29 0 04 22 22 0 10 18 18 0 26 1200 72 22 74 40 0 00 66 36 0 00 58 31 0 01 48 27 0 03 38 22 0 04 67 19 60 41 0 04 52 36 0 04 44 3...

Page 11: ...ERATURE _F 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 ENTERING AIR DRY BULB TEMPERATURE _C 26 25 25 24 24 Under 75 27 28 28 29 29 Over 85 Correction Factor 0 10 098 1 96 2 94 3 92 4 91 Use formula...

Page 12: ...ne 018 060 31 400 KFCEH3201F20 20 230 1 5 20 Fuse 030 060 62 800 KFCEH1601315 15 230 3 5 15 None 036 060 47 100 KFCEH2001318 18 230 3 6 12 18 None 042 060 56 500 KFCEH3401F24 24 230 3 8 16 24 Fuse 048...

Page 13: ...5 25 MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection ELECTRICAL DATA FOR UNITS WITHOUT ELECTRICAL HEAT MODEL NO MTR HP MTR FLA VOLTS PH HZ SINGLE CIRCUIT BRANCH CIRCUIT MIN WIRE SIZE AWG...

Page 14: ...3 None 37 6 41 5 55 5 60 4 6 6 10 8 60 70 76 77 KFCEH3201F20 20 15 0 1 Fuse 72 3 79 9 36 2 40 0 36 2 40 0 98 9 108 4 53 8 58 5 45 3 50 0 3 2 6 6 8 8 8 6 10 10 10 10 100 110 60 60 50 50 85 109 78 80 5...

Page 15: ...space must be insulated and covered with vapor barrier ACCESSORIES ITEM ACCESSORY PART NO FAN COIL SIZE USED WITH 1 Disconnect Kit KFADK0201DSC Cooling controls and heaters 3 through 10 kW 2 Downflow...

Page 16: ...4 light gauge high voltage wires SUGGESTED USE Fan coils with 15 and 20 kW fused heaters only 7 Filter Kit 12 pack The kit consists of 12 fan coil framed filters These filters collect large dust parti...

Reviews: