PHYSICAL DATA
UNIT SIZE SERIES
18---30
24---30
30---30,50
36---30,50,60
42---30,50,60
48---30,50,60
60---30,50,60
Operating Weight (lb)
135
135
149
166
210
236
261
Shipping Weight (lb)
156
156
171
189
238
264
295
Compressor Type
Scroll
REFRIGERANT
Puron
®
(R---410A)
Control
TXV (Puron
®
Hard Shutoff)
Charge (lb)
4.25
4.35
4.75
5.25
6.2
8.35
8.75
COND FAN
Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM)
1880
2200
2200
2950
3170
3365
4050
Motor HP
1/12
1/10
1/10
1/4
1/5
1/4
1/5
Motor RPM
1100
1100
1100
1100
1100
1100
825
COND COIL
Face Area (Sq. ft.)
9.85
9.85
11.49
14.77
17.25
21.56
25.15
Fins per In.
20
20
25
25
25
25
25
Rows
1
1
1
1
1
1
1
Circuits
3
3
3
3
4
5
5
VALVE CONNECT. (In. ID)
Vapor
5/8
5/8
3/4
3/4
7/8
7/8
7/8
Liquid
3/8
REFRIGERANT TUBES* (In. OD
)
Vapor (0---80 Ft. Tube Length)
5/8
5/8
3/4
3/4
7/8
7/8
1---1/8
Liquid (0---250 Ft. Tube Length)
3/8
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1--STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered ”long
line” when the total equivalent tubing length exceeds 80 ft or when
there is more than 20 ft. vertical separation between indoor and
outdoor units. These applications require additional accessories and
system modifications for reliable system operation. The maximum
allowable total equivalent length is 250Ft. The maximum vertical
separation is 200 Ft when outdoor unit is above indoor unit, and 80
ft. when the outdoor unit is below the indoor unit. Refer to
Accessory Usage Guideline for required accessories. See Long
Line Application Guideline for required piping and system
modifications. Also, refer to the table below for the acceptable
vapor tube diameters based on the total length to minimize the
cooling capacity loss.
UNIT
NOMINAL
SIZE
(BTUH)
ACCEPTABLE
LIQUID LINE
DIAMETERS
(IN. OD)
ACCEPTABLE
VAPOR LINE
DIAMETERS
(IN. OD)
COOLING CAPACITY LOSS (%)
TOTAL EQUIVALENT LINE LENGTH (FT..)
Standard Application
Long Line Application Requires Accessories
25
50
80
80+
100
125
150
175
200
225
250
18000
1 Stage
Puron AC
3/8
1/2
1
2
3
3
4
6
7
8
9
10
12
5/8
0
0
1
1
1
1
2
2
3
3
3
24000
1 Stage
Puron AC
3/8
5/8
0
1
1
1
2
3
3
4
4
5
6
3/4
0
0
0
0
0
1
1
1
1
1
2
7/8
0
0
0
0
0
0
0
0
0
0
1
30000
1 Stage
Puron AC
3/8
5/8
1
2
3
3
3
4
5
6
7
8
9
3/4
0
0
1
1
1
1
2
2
2
3
3
7/8
0
0
0
0
0
1
1
1
1
1
1
36000
1 Stage
Puron AC
3/8
5/8
1
2
4
4
5
6
7
9
10
11
13
3/4
0
0
1
1
1
2
2
3
3
4
4
7/8
0
0
0
0
0
1
1
1
1
2
2
42000
1 Stage
Puron AC
3/8
3/4
0
1
2
2
2
3
4
4
5
6
6
7/8
0
0
1
1
1
1
2
2
2
3
3
1 1/8
0
0
0
0
0
0
0
0
0
0
1
48000
1 Stage
Puron AC
3/8
3/4
0
1
2
2
3
4
5
5
6
7
8
7/8
0
0
1
1
1
2
2
2
3
3
4
1 1/8
0
0
0
0
0
0
0
0
1
1
1
60000
1 Stage
Puron AC
3/8
3/4
1
2
4
4
5
6
7
9
10
11
12
7/8
0
1
2
2
2
3
4
4
5
5
6
1 1/8
0
0
0
0
1
1
1
1
1
1
2
Standard Length = 80 ft. or less total equivalvent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guideline
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See
Long Line Application Guideline.
24AC
A
3
Summary of Contents for Comfort 24ACA3
Page 8: ...8 DIMENSIONS 24ACA3 ...