CNPHP: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

4

NOTE: Applications inside [  ] allowed but not recommended. Grey area not permitted.

NOTE: Applications inside [  ] allowed but not recommended. Grey area not permitted.

Installation Configurations

These units can be installed on a work platform, secured to roof trusses

in the attic, suspended from hangers on floor joists in the crawl space, or

installed  on  blocks.  See  proper  section  and  figures  for  detailed

installation instructions.

NOTE: 

Pan  extension  is  needed  for  both  horizontal  left  and  right

applications. DO NOT DISCARD.

FURNACE ATTACHMENT

Attach coil to furnace

The attachment plates (3) and filler plate (1) are packaged together and

placed in the coil carton. Remove these items, verifying the number of

pieces. Use the following procedure to attach CNPHP horizontal coil to

furnace.

NOTE: 

Remove  shipping  brace  from  both  ends  of  casing  prior  to

installation. Also remove corrugated shipping block from inside the right

end of casing prior to installation.

1. Three  attachment  plates  are  used  to  attach  coil  to  furnace.

Application determines which end of the coil will be attached to the

furnace.

2. Use self-tapping screws to mount attachment plates to coil casing

(

Fig. 5

).

A05419

Fig. 5 – Mount Attachment Plates

3. Connect furnace snugly against coil casing.
4. Use self-tapping screws to attach furnace (

Fig. 6

).

5. Seal joint between coil casing and furnace to create air-tight seal

using locally-approved materials.

A05420

Fig. 6 – Attach Coil to Furnace

NOTE: 

If the coil and furnace are different widths, refer to 

Fig. 4

 and

Table 1

 & 

Table 2

.

HORIZONTAL ATTIC INSTALLATION

Construct work platform to support coil/furnace combination

1. Construct  work  platform,  using  material  in  platform  that  will

support the weight of an installer or a service person.

2. Place work platform in front of discharge end of furnace.
3. Secure platform to building joists.

Install coil

To suspend CNPHP:

1. Cut metal plumbers strap to desired lengths.
2. Attach metal plumbers strap to four corners of coil casing (

Fig. 7

).

3.  Use a minimum of two screws per corner to attach plumbers strap

to casing.

4. Position and secure coil in front of furnace discharge end.
5. Make sure coil is level for proper condensate drainage.
6. Using appropriate fasteners for duct type, connect supply-air duct

to coil.

Table 1 – Heat Pump Right Hand Applications

Furnace Width- In. (mm)

Coil Width- In. (mm)

17.5 (445)

21 (533)

24.5 (622)

14 (356)

B, C

[B,C]

17.5 (445)

A

B, C, [D, E]

[B,C]

21 (533)

A

B, C, [D, E]

24.5 (622)

A

Table 2 – Air Conditioner Applications

Furnace Width- In. (mm)

Coil Width- In. (mm)

17.5 (445)

21 (533)

24.5 (622)

14 (356)

B, C, G, H

[B,C,G,H]

17.5 (445)

A, F

B,C,G,H [D,E,I,J]

[B,C,G,H]

21 (533)

A, F

B,C,G,H [D,E,I,J]

24.5 (622)

A, F

Self-Tapping Screws

Drill After Coil
   Is Installed 

Summary of Contents for CNPHP

Page 1: ...ult in enhanced installation reliability or operation NOTE Nitrogen can leak out through the needle pierce hole in the plugs This does not indicate a leaking coil nor warrant return of the coil INTRODUCTION The CNPHP is a horizontal multi use furnace coil Fig 1 With the use of field supplied transition duct these furnace coils can also be applied to other similar horizontal furnaces on the market ...

Page 2: ...V designed only for use with R 410A refrigerant Use only with outdoor units designed for R 410A NOTE All TXV S have preset superheat settings and are not field adjustable Cabinet Sweating If the unit is installed in a garage attic or other unconditioned space special attention may need to be given to the potential of cabinet sweating Condensate Management With proper installation these coils will ...

Page 3: ...stall and orientate the components as shown in Fig 4 Use Table 1 and Table 2 to identify which Application Letters A through J are acceptable for the furnace width and coil width being used in a specific situation Orientate and configure the furnace and coil as shown in each application A180215A Fig 4 Horizontal Installation Applications HORIZONTAL RIGHT INSTALLATIONS Acceptable for Air Conditione...

Page 4: ... Fig 5 A05419 Fig 5 Mount Attachment Plates 3 Connect furnace snugly against coil casing 4 Use self tapping screws to attach furnace Fig 6 5 Seal joint between coil casing and furnace to create air tight seal using locally approved materials A05420 Fig 6 Attach Coil to Furnace NOTE If the coil and furnace are different widths refer to Fig 4 and Table 1 Table 2 HORIZONTAL ATTIC INSTALLATION Constru...

Page 5: ...acuate tubing and reclaim refrigerant when making connections or flaring tubing Leak check connections before insulating entire suction line See Table 3 for coil connection tube size 1 Remove cabinet access door 2 Remove rubber plugs suction plug then liquid plug from coil stubs using a pulling and twisting motion Hold coil stubs steady to avoid bending or distorting 3 Remove tubing plate with rub...

Page 6: ...pan should be drained to a noticeable place As an alternative to using an external condensate pan some localities may allow the running of a separate 3 4 in 19 mm condensate line with appropriate trap per local code to a place where the condensate will be noticeable The owner of the structure must be informed that when condensate flows from secondary drain or external condensate pan the unit requi...