577E: Owner’s Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

5

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and changed or

cleaned whenever it becomes dirty. Dirty filters produce excessive stress

on the blower motor and can cause the motor to overheat and shut down.
This unit must have air filters in place before it can be operated.  These

filters can be located in one of at least two places. In many applications,

the installer will provide return air filter grilles mounted on the wall or

ceiling of the conditioned structure. In the instance of filter grilles, the

filters can simply be removed from the grille and replaced.
The other typical application is an accessory filter rack installed inside

the unit itself. The following information is given to assist in changing

filters used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory installed

option. The same filter kit is included with the accessory economizers

and factory installed economizers.

*

Units with bent indoor coil.

CAUTION

!

UNIT OPERATION HAZARD

Failure to follow this caution may result in property damage.

Never operate your  unit  without  filters  in  place. An accumulation  of

dust and lint on internal parts of your unit can cause loss of efficiency

and blower motor and/or compressor damage.

Table 1 – Indoor Air Filter Data

Unit Size

Filter Size in. (mm)

24-040/060

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

30-040/060

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

36-060/090

1 each 24 x 14 x 1 (610 x 406 x 25),

24 x 16 x 1 (610 x 406 x 25)

42-060/090

1 each 24 x 14 x 1 (610 x 356 x 25),

24 x 16 x 1 (610 x 406 x 25)

48-090/115/130

*

1 each 24 x 16 x 1 (610 x 406 x 25),

24 x 18 x 1 (610 x 457 x 25)

60-090/115/130

*

1 each 24 x 16 x 1 (610 x 406 x 25),

24 x 18 x 1 (610 x 457 x 25)

Summary of Contents for bryant Preferred 577E

Page 1: ...rred 15 and 16 SEER 2 Stage Packaged Air Conditioner and Gas Furnace System With Puron R 410A Refrigerant Single and Three Phase 2 5 Nominal Tons Sizes 24 60 Technician Name Phone Number Address Compa...

Page 2: ...roduct is used in or around the home or business that the dwelling be equipped with a CO Alarm s The Consumer Product Safety Commission recommends the use of CO Alarm s The CO Alarm s must be installe...

Page 3: ...rners do not light by the 4th ignition try of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting WARNING FIRE EXPLOSION ELECTRICAL SHOCK...

Page 4: ...with the following facts Cooling Mode With the SYSTEM control set to COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot day...

Page 5: ...following information is given to assist in changing filters used in these internal filter racks Filter kits are available as a purchased accessory or a factory installed option The same filter kit i...

Page 6: ...tions and designs without notice and without obligations 6 A13035 Fig 4 To Start Unit Gas Heat 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 460 VAC MODELS 72 ST...

Page 7: ...and designs without notice and without obligations 7 A13036 Fig 5 To Shut off Unit Gas Heat A09194 Fig 6 To Start Unit Electric Cooling 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP...

Page 8: ...Outdoor Fan The fan must be kept free of all obstructions to ensure proper cooling Contact your dealer for any required service Electrical Controls and Wiring Electrical controls are difficult to chec...

Page 9: ...this time Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details Complete service instructions can be found in the unit Installation St...

Page 10: ...needed to ensure proper function Repair or replace damaged or overheated components and wiring X Inspect temperature and pressure safety controls for damage X Inspect and clean if necessary burners a...

Reviews: