background image

GB - 3

42HQE009/012/018/022-38YE009/012/018/022  

E N G L I S H

There are some kinds of cord clamp in the accessory parts, if cord
clamp is not used as specified,the power cable and interconnection
wire will be damaged.

Please install the accessories attached with unit correctly according
to this installation manual.

Note:
1. At least two of A, B, C aspects are free from blocking.
2. When the Outdoor Unit is higher than the Indoor Units, to

prevent the rain from flowing into the indoor along the connection
pipe, a downward tipping arc should be made before the
connection pipe entering the wall to indoor to ensure  the lowest
point on the connection pipe is at outdoor.

3. The illustration  is for explanation purposes only. The actual

shape of would be slightly different (depend on models).

Cautions on remote controller installation
Before  installation,  operate  the  remote controller  to  determine
its  location in a reception range. Keep  the  remote  controller  at
least 1m apart  from the  nearest TV  set  or  stereo equipment.
Do  not  install  the  remote  controller in a place  exposed  to direct
sunlight or close to a heating source, such as a stove.
Note that the positive and negative poles are right positions when
loading batteries.

Anchor bolts of out door unit installation
The outdoor unit should not be exposed to strong wind.
Fix the outdoor unit with Ø 10 or Ø 8 anchor bolts.

Parts Installation

12 cm or more

15 cm or more

10 cm or more for 009, 012 e 018
45 cm or more for 022

60 cm or more

100 cm or more

Air blowing direction

Loop the connective cable

 

       


Model

D

E

38YE009

548

276

38YE012

530

290

38YE018

560

335

38YE022

560

335

A

B

C

D

E

Air inlet

Air outlet

Part No

Name of part

Q’ty

009 - 012,

018 - 022

Installation plate

1

1

Mounting screw A ST3.9x25-C-H

8

8

Clip anchor

8

8

 

Mounting screw B ST2.9x10-C-H

0

2

Refrigerant pipe

Liquid side

Ø 6.35

-

-

Ø 9.52

-

-

Gas side

Ø 9.52

-

-

Ø 12.7

-

-

Ø 15.88

-

-

Remote controller

1

1

Remote controller holder

1

1

Seal

1

1

Drain elbow

1

1

Cable clamp

Ø 9 (9 ~ 11.5 mm)

1

0

 (9 ~ 14mm)

1

1

Summary of Contents for ALLEGRO 38YE009

Page 1: ...42HQE009 012 018 022 38YE009 012 018 022 INSTALLATION MANUAL...

Page 2: ...ting installation plate 4 Connective Pipe and Drainage Installation 4 Dimensions and Minimum clearance 5 Wiring connection 6 Connecting Cables 6 Terminal block of indoor unit 6 Outdoor unit installati...

Page 3: ...The unit complies with low voltage EEC 73 23 and electromagnetic compatibility EEC 89 336 directives Carefully recover refrigerant within this unit before final disposal or when servicing Never vent...

Page 4: ...its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment Do not install the remote controller in a place exposed to direct sunlight or...

Page 5: ...d and rear left hand piping install the piping as shown Bend the connective pipe to be laid at 43 mm height or less from the wall 3 Fix the end of the connective pipe Refer to Tightening Connection in...

Page 6: ...asily be made by lifting the indoor unit B A C Dimensions and Minimum clearances mm Model 42HQE009 42HQE012 42HQE018 42HQE022 A mm 750 815 906 1080 B mm 250 280 286 330 C mm 188 195 235 222 Upper hook...

Page 7: ...nditioner takes a grounding leg so clients should use a grounding socket so that the air conditioner can be grounded efficiently If the power cord is damaged replacement should be conducted by qualifi...

Page 8: ...e If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram Outdoor unit installation A B C D E A F Minimum clearances mm Mo...

Page 9: ...e outdoor unit 2 Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units 3 To prevent the ingress of water...

Page 10: ...ld valve and stop the operation of the vacuum pump Make evacuation for 15 minutes and more and check that the compound meter indicates 76cmHg 1 0x105 Pa 6 Disconnect the charge hose from the charge co...

Page 11: ...42HQE 38YE IOM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice December 2004...

Reviews: