Driver Troubleshooting 

AddVolt  produces  its  entire  product  range  within  the  highest  level  of  quality  and  reliability. 
However, if the unit is

n’t

 handled correctly, it shows certain alerts to guide the user to restore 

its normal operation. 

 

 

If the problem you are experiencing with the unit is not listed in this section, please contact your 
AddVolt service partner. 

 

Symptom 

Possible Causes 

Possible Solutions 

Refrigeration unit 

detects 

“NO 

POWER” 

 

Refrigeration unit tried to 
start before the AddVolt 
system is ready. 

Shutdown Refrigeration unit and start AddVolt 
system before the refrigeration unit. 

AddVolt system is in sleep 
mode / critically 
discharged. 

Connect to the power grid, turn service 
disconnect OFF and ON.  Follow instructions in 
Alarm Signal section. 

Fuse in FUBO (Fuse Box) 
broken. 

Press the service disconnect and disconnect 
from power grid. Measure continuity of all 
fuses in FUBO. Replace all broken fuses. 

Defect on cabling / 
connectors. 

Open Motor and Grid/Gen power cables 
connectors on AddVolt system back and 
visually inspect for defects. 

Refrigeration unit in 

electric stops before 

reaching setpoint

 

AddVolt unit is completely 
discharged. 

Charge AddVolt system before trying again. 

Device failed. 

Check if “fail” is active on 

display.  Follow 

instructions in Alarm Signal section. 

Refrigeration unit 

does not start from 

AddVolt system nor 

power grid

 

Fuse in FUBO (Fuse Box) 
broken. 

Press service disconnect and disconnect from 
grid. Measure continuity of all fuses in FUBO. 
Replace all broken fuses. 

Issue on refrigeration unit 

Check Service Manual of refrigeration unit. 

Summary of Contents for AddVolt

Page 1: ...62 61974 01 User Manual...

Page 2: ...Volt system connected to the power grid 10 4 5 Charging and supplying the Refrigeration unit 11 4 6 Charging the AddVolt unit through the generator 12 4 7 Charging and supplying the Refrigeration unit...

Page 3: ...50Hz grid on board of the vehicle making possible supply the electrical standby motor anytime Main benefits of the AddVolt systems Enables day and night access to city centers Compatible with all veh...

Page 4: ...installed in drawbars or trailers 1 AddVolt Plug in Electric system attached to the vehicle 2 Display 3 My AddVolt digital platform for monitoring by the fleet manager Every product is accompanied by...

Page 5: ...R ADDM2517 R ADDM3014 R ADDM3817 R ADDL3021 R may be used in load constantly at temperatures below zero to avoid the battery internal temperature to drop below 0 C for Charging and 11 C for dischargin...

Page 6: ...h danger to people with heart pacemakers metal implants and hearing aids People with a heart pacemaker metal implants or hearing aids must consult a doctor before they enter areas nearby the AddVolt s...

Page 7: ...ut of the outlets directly by the cables Always pull by the connectors Before removing the vehicle from the dock disconnect vehicle from the power grid Cables that are damaged may cause Electrocutions...

Page 8: ...e Refrigeration unit in electric mode make sure that the green button of the AddVolt system is pressed as shown in the image In this case the only button that must be actuated is the green button The...

Page 9: ...energy The OFF light of the display will appear in white 4 3 Supply Refrigeration unit using AddVolt system Whenever the user needs to operate the Refrigeration unit in electric mode and the AddVolt...

Page 10: ...charging automatically and the ON light will be either blinking or lit in white 5 The autonomy indicators will blink during charge representing the battery level Notes 1 When the vehicle is parked It...

Page 11: ...Refrigeration unit will start automatically 6 The display will activate the electric motor indicator meaning that the Refrigeration unit is operating in electric mode 7 Wait 30 seconds the system will...

Page 12: ...evel 4 7 Charging and supplying the Refrigeration unit through the generator Whenever the generator is producing energy while the refrigeration unit is operating at the same time 1 The system will sta...

Page 13: ...turn service disconnect OFF and ON Follow instructions in Alarm Signal section Fuse in FUBO Fuse Box broken Press the service disconnect and disconnect from power grid Measure continuity of all fuses...

Page 14: ...low below 25 Please charge the AddVolt un it connecting it to the power grid 5 3 Alarm signals System blackout When the system is critically discharged it shuts down for safety and all the lights are...

Page 15: ...aintenance must be performed only by trained and approved personnel by AddVolt This unit operates with high voltage levels Use insulated tools whenever necessary Make sure the device is shutdown 15 mi...

Page 16: ...in the power or signal cables Monthly Check electrical connections inside the fuse box Every 6 month Mechanical coupling Check if device s screws to chassis have moved At each vehicle overhaul minimum...

Page 17: ...st Carrier Transicold service centre Consult the directory to locate the service centre nearest you This directory may be obtained from your Carrier Transicold dealer If you are unable to reach a serv...

Page 18: ...Your name the name of your company and your location A telephone number where you can be called back Refrigeration unit model and serial number Box temperature Set point and product Brief description...

Reviews: