10
S
Close to or in a frequently used room, preferably on an inside partition-
ing wall.
S
On a section of wall without pipes or duct work.
Thermidistat Control should NOT be mounted:
S
Close to a window, on an outside wall, or next to a door leading to the
outside.
S
Exposed to direct light or heat from a lamp, sun, fireplace, or other tem-
perature--radiating objects which could cause a false reading.
S
Close to or in direct airflow from supply registers and return--air re-
gisters.
S
In areas with poor air circulation, such as behind a door or in an alcove.
Installer should determine whether control will be installed as single--piece or
two--piece. In single--piece configuration, as many as 14 wires may need to run to
wall mounting location for connection to the control. In two--piece configuration,
the Display Module and Equipment Control Module are connected by two wires.
Install Thermidistat Control
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing Thermidistat Control, turn off all power to
equipment. There may be more than 1 power disconnect.
!
WARNING