![Carrier 69NT40--541--200 TO 299 Operation And Service Download Page 22](http://html1.mh-extra.com/html/carrier/69nt40-541-200-to-299/69nt40-541-200-to-299_operation-and-service_2563837022.webp)
T-317
2-7
2.2 REFRIGERATION SYSTEM DATA
a. Compressor/Motor
Assembly
Number of Cylinders
6
Model
06DR
CFM
41
Weight (Dry)
118 kg (260 lb)
Approved Oil
Castrol Icematic SW--20
Oil Charge
3.6 liters (7.6 U.S. pints)
Oil Sight Glass
The oil level range, with the compressor off,
should be between the bottom and one-eighth
level of the sight glass.
b. Expansion Valve Superheat
Verify at --18
_
C
(0
_
F) container box
temperature
4.5 to 6.7
_
C (8 to 12
_
F)
c. Heater Termination Thermostat
Opens
54 (
¦
3)
_
C = 130 (
¦
5)
_
F
Closes
38 (
¦
4)
_
C = 100 (
¦
7)
_
F
d. High Pressure Switch
Cutout
25 (
¦
1.0) kg/cm
@
= 350 (
¦
10) psig
Cut-In
18 (
¦
0.7) kg/cm
@
= 250 (
¦
10) psig
e. Refrigerant Charge
Unit Configuration
Charge Requirements -- R-134a
3 row condenser
Water-Cooled
Condenser
4.9 kg
(10.75 lbs)
Receiver
4.0 kg
(8.8 lbs)
NOTE
When replacing the following components (f.), (g.) and (h.) , refer to the installation instructions included with
the replacement part for additional information.
f. Fusible Plug*
Melting point
99
_
C = (210
_
F)
Torque*
6.2 to 6.9 mkg (45 to 50 ft-lbs)
g. Sight Glass/Moisture Indicator
Torque
8.9 to 9.7 mkg (65 to 70 ft-lbs)
h. Rupture Disc
Bursts at
35
¦
5% kg/cm
@
= (500
¦
5% psig)
Torque
(P/N 14-00215-03)
1.4 to 2 mkg (10 to 15 ft-lbs)
i. Condenser Pressure
Transducer
Condenser Fan Starts
The condenser fan will start if the condenser
pressure is greater than 14.06 kg/cm
@
(200
psig) OR the condenser fan is OFF for more
than 60 seconds.
Condenser Fan Stops
The condenser fan will stop if the condenser
pressure is less than 9.14 kg/cm
@
(130 psig)
AND the condenser fan remains ON for at least
30 seconds.
j. Unit Weight
Refer to unit model number plate.
k. Water Pressure Switch
Cut-In
0.5
¦
0.2 kg/cm
@
(7
¦
3 psig)
Cutout
1.6
¦
0.4 kg/cm
@
(22
¦
5 psig)
l. Discharge Pressure Regulator
Factory Setting
32.7
¦
2.5 kg/cm
@
(72
¦
5.5 psig)
* Rupture Disc, part number 14--00215--04 may be installed as an alternate for the receiver mounted fusible plug.