SECTION 1
INTRODUCTION
1.1 INTRODUCTION
WARNING
It has been determined that pressurized,
air-rich mixtures of refrigerants and air can
undergo combustion when exposed to an
ignition source.
This manual contains Operating Data, Electrical Data
and Service Instructions for the refrigeration units listed
in Table 1-1. Also, Table 1-1 charts some significant
differences between these models.
NOTE
Beginning with early 1995 production, in
addition to a model number, Carrier Transicold
began using a parts identification (PID) number
in the format NT0000. In the parts manual, the
PID number is shown in boldface to point out
parts variations within models. The PID
number must be included when ordering and
inquiring about your unit.
The unit, of lightweight aluminum frame construction,
is an all electric, one piece, self-contained cooling and
heating refrigeration unit. The unit is designed to fit in
the front of a container and to serve as the container front
wall. Forklift pockets are provided for installation and
removal of the unit.
The unit is complete with a charge of R-134a,
compressor lubricating oil (approved POE SW20
compressor oil for R-134a only), mode indicating
lights, and temperature controller, and is ready for
operation upon installation.
Some units are equipped with a two-speed compressor
that is used to enhance power saving.
Some units are dual voltage units designed to operate on
190/230 or 380/460 volts AC, 3-phase, 50-60 hertz
power (refer to section 2.4). Other units are designed to
operate on 380/460 volts AC, 3-phase 50/60 hertz
power only. An external autotransformer is required for
190/230 vac operation (refer to Figure 2-9 and section
2.4).
Operating control power is provided by a control
transformer which steps down the AC supply power
source to 18 and 24 volts AC, single phase control
power.
The temperature Controller/DataCORDER (Micro-Link
2i) is a microprocessor-based controller and a integrated
electronic data logging device. Refer to sections 3.1 and
3.3. Once the temperature controller is set at a desired
container temperature, the unit will operate automatically
to maintain the desired temperature within very close
limits. The control system automatically selects cooling,
holding or heating as necessary to maintain the desired
temperature within the container.
WARNING
Beware of unannounced starting of the
evaporator and condenser fans. Do not open
the condenser fan grille before turning
power OFF and disconnecting power plug.
Some units are equipped with a mechanical temperature
recorder.
Some units may have a TransFRESH controlled
atmosphere system added. Contact TransFRESH
Corporation, P.O. Box 1788, Salinas, CA 93902 for
information on their system.