Roof terminations--
Locate assembly through roof to
appropriate height as shown in Fig. 31 and 32.
Sidewall
terminations--
Locate
assembly
through
sidewall with rain shield positioned no more than 1--in.
from wall as shown in Fig. 31 and 32.
4. Disassemble loose pipe fittings. Clean and cement using
same procedures as used for system piping.
5. Check required dimensions as shown.
Two--Pipe Termination Kit (Direct Vent/2--Pipe System Only
Determine an appropriate location for termination kit using the
guidelines provided in section “Vent Termination: General” in
this instruction.
1. Cut 2 holes, 1 for each pipe, of appropriate size for pipe
size being used.
2. Loosely install elbow in bracket and place assembly on
combustion--air pipe.
Roof terminations--
Loosely install pipe coupling on
properly cut vent pipe. Coupling must be positioned so
bracket will mount as shown in Fig. 31.
For applications using combustion--air pipe option,
indicated by dashed lines in Fig. 31, install 90
_
street
elbow into 90
_
elbow, making a U--fitting. A 180
_
U--fitting may be used.
Sidewall terminations--
Install bracket as shown in Fig.
31.
For applications using vent pipe option indicated by
dashed lines in Fig. 31, rotate vent elbow 90
_
from
position shown in Fig. 31.
3. Disassemble loose pipe fittings. Clean and cement using
same procedures as used for system piping.
4. Check required dimensions as shown in Fig. 31.
Multiventing and Vent Terminations
When 2 or more 58UVB Furnaces are vented near each other,
each furnace must be individually vented. NEVER common vent
or breach vent 58UVB furnaces.
(Direct Vent/2--Pipe System ONLY)--When 2 or more 58UVB
furnaces are vented near each other, 2 vent terminations may be
installed as shown in Fig. 31, but next vent termination must be at
least 36 in. away from first 2 terminations. It is important that
vent terminations be made as shown in Fig. 31 to avoid
recirculation of flue gases.
FLASH
UPGRADE
CONNECTOR
(FACTORY
ONLY)
ACRDJ AIR
CONDITIONING
RELAY DISABLE
JUMPER
HUMIDIFIER
TERMINAL (24-VAC
0.5 AMP MAX.
CONTINUOUS FAN
(CF) AIRFLOW
SETUP SWITCHES
COMMUNICATION
CONNECTOR
AIR CONDITIONING
(A/C) AIRFLOW
SETUP SWITCHES
MODEL PLUG
CONNECTOR
SW1 SETUP
SWITCHES AND
BLOWER OFF-
DELAY
STATUS AND COMM
LED LIGHTS
3-AMP FUSE
TRANSFORMER 24-VAC
CONNECTIONS
PL3 ECM BLOWER
HARNESS
CONNECTOR
PL1 LOW VOLTAGE MAIN
HARNESS CONNECTOR
EAC-1 TERMINAL
(115-VAC 1.0 AMP MAX.)
115-VAC (L1) LINE
VOLTAGE CONNECTIONS
115-VAC (L2) NEUTRAL
CONNECTIONS
PL2 HOT SURFACE
IGNITER & INDUCER
MOTOR CONNECTOR
24-V THERMOSTAT
TERMINALS
FUTURE
APPLICATIONS
DATE CODE XXXXN
A06494
Fig. 33
---
Control Center
58U
VB