background image

Copyright 2006 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

Printed in U.S.A.

edition date: 

10

/06

           Catalog No:  58MCB-2PD

Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations

                                                          

Replaces: 58MCB-1PD

Rev. A

GENERAL
System Description
Furnish a _________________    (4-way multi-poise) fixed ca-
pacity gas-fired condensing furnace for use with natural gas or 
propane (factory authorized conversion kit required for pro-
pane); furnish cold air return plenum; furnish side (external) fil-
ter rack.
Quality Assurance
Unit will be designed, tested and constructed to the current 
ANSI Z 21.47/CSA 2.3 design standard for gas-fired central 
furnaces. 
Unit will be 3rd party certified by CSA to the current ANSI Z 
21.47/CSA 2.3 design standard for gas-fired central furnaces. 
Unit will carry the CSA Blue Star® and Blue Flame® labels.
Unit efficiency testing will be performed per the current DOE 
test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in 
the latest GAMA Consumer’s Directory of Certified Efficiency 
Ratings.
Unit will carry the current Federal Trade Commission Energy 
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and 
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon re-
quest.

PRODUCTS
Equipment 
Components shall include: slow-opening gas valve to reduce ig-
nition noise, regulate gas flow, with electric switch gas shut-off; 
flame proving sensor, hot surface igniter, pressure switch as-
sembly verifies inducer operation; flame rollout switch, drain 
tubing and installed condensate drain trap, blower and inducer 
assembly, 40va transformer; low-voltage (heating) (heating/
cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically 
and dynamically balanced. Blower motor of PSC type shall be 
permanently lubricated with sealed bearings, of _____ hp, and 
shall be multiple-speed direct drive. Blower motor shall be soft 
mounted to the blower scroll to reduce vibration transmission.
Filters
Furnace shall have reusable-type filters. Filter shall be ______ 
in  (x) ______in.

Casing
Casing shall be of .030 in. thickness minimum, pre-painted gal-
vanized steel.
Inducer Motor 
Inducer motor shall be soft mounted to reduce vibration trans-
mission.
Primary Heat Exchangers
Primary Heat exchangers shall be 3-Pass 20 gauge corrosion re-
sistant aluminized steel of fold-and-crimp sectional design, 
which operates under negative pressure.  
Secondary Heat Exchangers
Secondary Heat exchangers shall be of a flow-through design 
having a patented interior laminate coating of polypropylene for 
greater corrosion resistance with fold-and-crimp design, which 
operates under negative pressure.
Controls
Controls shall include a micro-processor based integrated elec-
tronic control board with at least 11 service troubleshooting 
codes displayed via diagnostic flashing LED light on the con-
trol, has ability to store fault codes, when activated a self-test 
feature checks all major functions of the furnace within one 
minute, and a replaceable automotive-type circuit protection 
fuse.  Multiple operational settings available including separate 
blower speeds.  Cooling airflow will be selectable between 350 
or 400 CFM per ton of air conditioning. 
Operating Characteristics
Heating Capacity shall be _________ Btuh input; 
____________ Btuh output capacity.
Fuel Gas Efficiency shall be 92% AFUE.
Air delivery shall be  __________ cfm minimum at 0.50 in. wg. 
external static pressure.
Dimensions shall be: depth __________ in.; width __________ 
in.; height _________ in. (casing only). Height shall be 
__________ in. with A/C coil and ____________ in. overall 
with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single-phase (nom-
inal). Minimum wire size shall be _________ AWG; maximum 
fuse size or HACR-type, designated circuit breaker shall be 
_______ Amps. 
Special Features
Refer to section of the product data sheet identifying accesso-
ries and descriptions for specific features and available en-
hancements.

Guide Specifications

Base 90

Single-Stage Gas Furnace

58MCB

Summary of Contents for 58MCB040

Page 1: ...ryconfiguredforupflow applicationbutcaneasilybemadeready for downflow or horizontal installation With the exception of the 140 size all sizes can be installed with 2 pipe or 1 pipe venting The 140 size can be installed only as a 2 pipe system Horizontal applications offer the ad vantage of reduced space requirements by locating the furnace in an attic or crawlspace freeing space formerly ded icate...

Page 2: ... indicator light to assist in trouble shooting Controltimesblowerstartafter main burners ignite to eliminate cold air blowing into rooms Warranties 20 year Warranty on the heat exchangers Five year Warranty on entire unit Contact your dealer for details Direct or Non direct Venting The 58MCB can be installed as a 1 pipe Non Direct vent or 2 pipe Direct vent furnace except the 140 size which can be...

Page 3: ...products through furnace and out vent system Combustion inducer pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety Condensate drain connection collects moisture condensed during the combustion process Heavy duty blower circulates air across the heat exchangers to transfer heat into the home Air filter and retainer may be used for side or bottom return a...

Page 4: ... HEATING BLOWER CONTROL Off Delay Selectable 90 120 150 or 180 sec BURNERS Monoport 2 2 3 3 3 4 4 4 5 5 6 6 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface UNIT SIZE 040 08 040 12 060 08 060 12 060 16 080 12 080 16 080 20 100 16 100 20 120 20 140 20 G...

Page 5: ...ay Programmable TSTATCCPHP01 B For use with 1 spd Air Conditioner deg F C Auto Changeover 7 Day Programmable TSTATCCP2S01 B For use with 2 spd Air Conditioner deg F C Auto Changeover 7 Day Programmable TSTATCCSAC01 For use with 1 spd Air Conditioner deg F C 5 2 Day Programmable TSTATCCPDF01 B For use with multi stage applications deg F C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi ...

Page 6: ...etter condition Moisturizing house hold air also helps to retain nor mal body heat and provides comfort at lower temperatures A93086 CONCENTRIC VENT Direct Vent 2 Pipe Application A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn i...

Page 7: ... CONDENSATE DRAIN TRAP LOCATION DOWNFLOW HORIZONTAL RIGHT OR ALTERNATE 1 2 IN DIA GAS CONN NOTES Minimum return air opening at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendation for equivalent diameters 1 For 800 CFM 16 in round or 14 1 2 X 12 in rectangle 2 For 1200 CFM 20 in round or 14 1 2 X 19 1 2 in rectangle 3 For 1600 CFM 22 in round or 14 1 2 X 23 ...

Page 8: ...19 20 1 4 20 3 8 2 24 1 2 Furnace with or without Cased Coil Assembly or KCAKC Coil Box 22 1 8 19 23 3 4 20 3 8 1 LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D Assembled Disassembled A97427 A88207 C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION A96211 FIELD SUPPLIED 2 IN DIAMETER PVC PIPE FIELD SUPPLIED 2 IN DIAMETER PVC 90 ELBOW COMBUSTION AIR DISC FACTORY SUPPLIED IN LOO...

Page 9: ... Vent 2 Pipe Application All Model Sizes CONDENSATE TRAP 1 2 OD INDUCER HOUSING DRAIN CONNECTION 1 4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5 8 OD COLLECTOR BOX DRAIN CONNECTION 1 2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE D...

Page 10: ...cial base No KGASB0201ALL Coil Assembly Part No CD5 or CK5 or Coil Casing PartNo KCAKC Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket and building joists studs or framing Clearance shown is for air inlet and air outlet ends 120 and 140 size furnaces require 1 inch bottomclearance to combustible materials Ø Clearance in inches Dégagemen...

Page 11: ...860 080 20 1 side or bottom High Med High Med Low Low 2200 2100 1815 1560 2175 2025 1760 1555 2085 1945 1720 1515 2025 1865 1670 1460 1925 1785 1620 1435 1820 1700 1550 1390 1735 1620 1480 1340 1635 1540 1405 1270 both sides or 1 side and bottom High Med High 2360 1965 2280 1925 2210 1870 2130 1830 2035 1760 1960 1710 1875 1670 1790 1575 100 16 1 side or bottom High Med High Med Low Low 1740 1500 ...

Page 12: ...NA 2 2 70 67 66 61 61 61 80 000 2 Pipe or 2 in Concentric 2 2 49 44 30 25 25 15 2 1 2 2 1 2 70 70 70 70 70 70 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 35 26 16 16 6 NA 3 3 70 70 70 70 66 61 120 000 2 Pipe or 3 in Concentric 3 NA 14 9 NA NA NA NA NA 3 63 62 62 61 61 61 3 no disk NA 70 70 63 56 50 43 4 no disk 4 no disk 70 70 70 70 70 70 140 000 2 Pipe or 3 in Concentric 3 one disk NA 20 15 10 ...

Page 13: ...55 54 49 48 47 80 000 2 Pipe or 2 in Concentric 2 2 41 36 23 18 17 8 2 1 2 2 1 2 70 70 70 70 70 70 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 29 21 12 11 NA NA 3 3 70 67 62 57 52 47 120 000 2 Pipe or 3 in Concentric 3 no disk NA 42 35 29 22 15 9 NA 3 53 52 50 49 48 47 4 no disk 4 no disk 70 70 70 70 70 70 140 000 2 Pipe or 3 in Concentric 3 no disk NA 12 8 NA NA NA NA 4 no disk NA 42 37 32 27 2...

Page 14: ...40 000 2 Pipe or 2 in Concentric 1 1 2 1 1 2 42 37 32 27 25 20 2 2 57 55 53 51 49 47 60 000 2 Pipe or 2 in Concentric 2 2 45 40 38 33 31 29 80 000 2 Pipe or 2 in Concentric 2 2 30 25 14 9 7 NA 2 1 2 2 1 2 57 55 53 51 49 47 100 000 2 Pipe or 3 in Concentric 2 1 2 2 1 2 21 13 5 NA NA NA 3 3 54 49 44 39 34 29 120 000 2 Pipe or 3 in Concentric NA 3 39 37 35 33 31 29 4 no disk 4 no disk 10 5 NA NA NA N...

Page 15: ... 20 140 20 CERTIFIED TEMP RISE RANGE F 30 60 15 45 45 75 30 60 20 50 40 70 30 60 20 50 45 75 30 60 40 70 50 80 CERTIFIED EXT STATIC PRESSURE Heating 0 10 0 10 0 12 0 12 0 12 0 15 0 15 0 15 0 20 0 20 0 20 0 20 In wc Cooling 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 AIRFLOW CFM Heating 850 1125 885 1065 1320 1190 1285 1785 1315 1690 1720 1970 Cooling 895 1215 900 1200 1545 1245 152...

Page 16: ... SIZE 14 14 14 14 14 14 14 12 14 12 12 12 MAXIMUM WIRE LENGTH Ft 44 37 44 38 29 36 28 31 27 30 30 30 MAXIMUM FUSE SIZE OR CKT BKR Amps 15 15 15 15 15 15 15 20 15 20 20 20 TRANSFORMER 24v 40va EXTERNAL CONTROL POWER AVAILABLE Heating 12va Cooling 21va AIR CONDITIONING BLOWER RELAY Standard A02174 115 V FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE N...

Page 17: ... FRONT OF FURNACE A05065 COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBUSTION AIR INLET NON DIRECT 1 PIPE APPLICATION A05064 Typical installations Basement Upflow Application A05064 ...

Page 18: ...ACE A05067 COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION COMBUSTION AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT 2 PIPE APPLICATION COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION Attic Horizontal Application Crawlspace Horizontal Application A05067 A05066 ...

Page 19: ...19 58MCB ...

Page 20: ...with sealed bearings of _____ hp and shall be multiple speed direct drive Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission Filters Furnace shall have reusable type filters Filter shall be ______ in x ______in Casing Casing shall be of 030 in thickness minimum pre painted gal vanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration ...