GUIDE SPECIFICATIONS

Gas Furnace

58CTA/CTX

General

SYSTEM DESCRIPTION

Furnish a _________________ fixed capacity gas-fired

furnace for use with natural gas or propane (factory

authorized conversion kit required for propane); furnish

cold air return plenum; furnish external medial cabinet for

use with accessory media filter or standard filter.

QUALITY ASSURANCE

Unit will be designed, tested and constructed to the

current ANSI Z 21.47/CSA 2.3 design standard for

gas--fired central furnaces.

Unit will be 3rd party certified by CSA to the current

ANSI Z 21.47/CSA 2.3 design standard for gas--fired

central furnaces.

Unit will carry the CSA Blue Star

R

and Blue Flame

R

labels.

Unit efficiency testing will be performed per the current

DOE test procedure as listed in the Federal Register.

Unit will be certified for capacity and efficiency and

listed in the latest GAMA Consumer’s Directory of

Certified Efficiency Ratings.

Unit shall carry the current Federal Trade Commission

Energy Guide efficiency label.

DELIVERY, STORAGE AND HANDLING

Unit shall be shipped as single package only and is

stored

and

handled

per

unit

manufacturer’s

recommendations.

WARRANTY (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available

upon request.

Products

EQUIPMENT

Components shall include: slow-opening two stage gas

valve to reduce ignition noise, regulate gas flow, with

electric switch gas shut-off; flame proving sensor, hot

surface igniter, pressure switch assembly, flame rollout

switch, blower and inducer assembly, 40va transformer;

low-voltage (heating) (heating/cooling) thermostat.

Blower Wheel and Blower Motor

Galvanized blower wheel shall be centrifugal type,

statically and dynamically balanced. Blower motor of PSC

type shall be permanently lubricated with sealed bearings,

of _______hp, and shall be multiple-speed direct drive.

Blower motor shall be soft mounted to the blower scroll to

reduce vibration transmission.

Filters

Furnace may have reusable--type filters. Filter shall be

_______ (x) _______in. (mm). An accessory high

efficiency Media Filter is available as an option.

_______________ Media Filter.

Casing

Casing shall be of .030 in. (.76 mm) thickness

minimum, pre-painted galvanized steel.

Two Speed Inducer Motor

Two Speed Inducer motor shall be soft mounted to

reduce vibration transmission.

Draft Safeguard Switch

Draft Safeguard Switch (blocked vent safeguard) shall

be factory installed to reduce the possibility of vent gas

infiltration due to a blocked or restricted vent pipe.

Heat Exchangers

Heat exchangers shall be a 4-Pass 20 gage aluminized

steel of fold--and--crimp sectional design when applied

operating under negative pressure.

Controls

Control shall include a micro--processor based

integrated electronic control board with at least 11 service

troubleshooting codes displayed via diagnostic flashing

LED light on the control, a self--test feature that checks all

major functions of the furnace within one minute, and a

replaceable automotive-type circuit protection fuse.

Multiple operational settings available including, separate

blower speeds for low heat, high heat, low cooling, high

cooling and continuous fan. Continuous fan speed may be

adjusted from the thermostat. Cooling airflow will be

selectable between 350 or 400 CFM per ton of air

conditioning. Features will also include temporary reduced

airflow

in

the

cooling

mode

for

improved

dehumidification

when

an

Infinity

t

Control or

Thermidistat

t

is selected as the thermostat.

OPERATING CHARACTERISTICS

Heating Capacity shall be ________ Btuh input;

________ Btuh output capacity.

Fuel Gas Efficiency shall be 80% AFUE.

Air delivery shall be ___________ cfm minimum at

0.50 in. wc external static pressure.

Dimensions shall be: depth __________ in. (mm);

width _________ in. (mm); height_________in. (mm).

(casing only). Height shall be_________in. (mm). with

A/C coil and _____________in. (mm) overall with

plenum.

ELECTRICAL REQUIREMENTS

Electrical supply shall be 115 volts, 60 Hz,

single--phase (nominal). Minimum wire size shall

be_________AWG; maximum fuse size or circuit breaker

shall be __________Amps.

SPECIAL FEATURES

Refer to section of the product data sheet identifying

accessories and descriptions for specific features and

available enhancements.

Copyright 2009 Carrier Corp.

D

7310 W. Morris St.

D

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 2/09

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: 58CT---6PD

Replaces: 58CT--- 5PD

58C

TA

/C

TX

Summary of Contents for 58CTA/CTX

Page 1: ...ology Intelligent microprocessor control S Two stage heating with single stage thermostat with patented Adaptive Control Technology S Very low operating sound through low stage operation and QuieTecht system SmartEvapt Humidity control when using a Thermidistatt Infinityt control Comfort Fant adjustable constant fan speed from the thermostat S High Efficiency Media Filtration Cabinet included S Mi...

Page 2: ...00 Btuh 08 800 CFf7 12 1200 CFM 14 1400 CFM 16 1600 CFM Input Capacity 20 2000 CFM 045 44 000 Btuh 110 110 000 Btuh 22 2200 CFM 070 66 000 Btuh 135 132 000 Btuh 090 88 000 Btuh 155 154 000 Btuh Series Number EFFICIENCY RATING CERTIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS Before purchasing this appliance read important energy cost and efficiency information available from ...

Page 3: ...TCH BLOWER AND MOTOR RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH FLAME SENSOR Elbow may be turned to a different position depending on type of installation A04138 NOTE The 58CTA CTX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion ...

Page 4: ... C Auto Changeover TP NAC TC NAC For use with 1 speed Heat Pump deg F C Auto Changeover TP NHP TC NHP For use with 2 speed Air Conditioner deg F C Auto Changeover TP NRH For use with multi use stage configurations deg F C Auto Changeover Temperature and Humidity control TP PRH THERMOSTAT PROGRAMMABLE For use with 1 speed Air Conditioner deg F C Auto Changeover 7 Day Programmable TP PAC For use wit...

Page 5: ...2UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X X X X X KGACA02015FC X X X Natural to Propane Conversion Kit KGANP4601ALL X X X X...

Page 6: ...75 1195 1265 1030 1580 1325 Cooling 895 1175 955 1240 1605 1385 1755 2005 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 2 2 3 3 3 4 4 4 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certi...

Page 7: ...2230 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 5 5 5 6 6 7 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M r...

Page 8: ...installations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit KGAVG0101DFG required in downflow installations with bottom vent configuration 7 ...

Page 9: ... 8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02066 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02067 58CTA CTX ...

Page 10: ... 1320 1160 1465 1380 1260 1120 1385 1300 1195 1065 1285 1220 1120 1005 1175 1115 1025 925 1055 990 915 810 895 830 710 630 645 600 565 510 090 16 Bottom or Side s High Med High Medium Med Low Low 2060 1710 1470 1260 1030 2000 1695 1475 1265 1025 1930 1665 1450 1245 1020 1835 1585 1390 1225 990 1755 1480 1335 1165 940 1620 1390 1230 1090 890 1490 1245 1120 995 810 1315 1110 1005 880 720 1115 955 85...

Page 11: ...05 1500 1295 1835 1640 1450 1265 1710 1550 1380 1210 1590 1465 1315 1150 1470 1360 1215 995 1335 1210 1005 865 1025 945 855 745 835 785 670 540 135 22 Bottom Only High Med High Med Low Low 2485 2195 1880 1640 2400 2150 1850 1635 2310 2090 1820 1615 2215 2000 1780 1585 2110 1920 1715 1530 2000 1825 1635 1465 1880 1720 1540 1370 1725 1565 1415 1255 1535 1405 1290 1150 1355 1255 1160 1040 Both Sides ...

Page 12: ...e use of both side inlets a combination of 1 side and the bottom or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM FURNACE SIZE A CABINET WIDTH IN mm D SUPPLY AIR WIDTH IN mm E RETURN AIR WIDTH IN mm F CENTER LINE TOP AND BOTTOM FLUE COLLAR IN mm FLUE COLLAR IN mm SHIP WT LB KG FILTER MEDIA CABINET IN mm 045 08 14 3 16 360 12 9 16 319 12 11 16 322 ...

Page 13: ...7 432 16 1 4 413 15 381 20 508 mm 21 533 20 1 4 514 19 483 24 610 mm 25 635 24 1 4 616 23 584 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 1 2 With Flanges Bent Out 23 1 8 Opening 5 3 4 C Opening with Flanges Bent In B 600 mm 594 mm 603 mm 146 mm 651 mm 622 mm 587 mm A00444 58CTA CTX 58CTA CTX ...

Page 14: ...14 A08471 58CTA CTX ...

Page 15: ... 2 15 14 090 14 115 60 1 127 104 8 2 34 10 3 15 14 090 16 115 60 1 127 104 9 9 28 8 5 15 14 090 20 115 60 1 127 104 12 9 34 10 3 20 12 110 12 115 60 1 127 104 8 2 34 10 3 15 14 110 16 115 60 1 127 104 10 1 28 8 5 15 14 110 22 115 60 1 127 104 13 7 32 9 7 20 12 135 16 115 60 1 127 104 10 2 27 8 2 15 14 135 22 115 60 1 127 104 14 5 30 9 1 20 12 155 20 115 60 1 127 104 15 0 29 8 8 20 12 Permissible l...

Page 16: ...f 030 in 76 mm thickness minimum pre painted galvanized steel Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe Heat Exchangers Heat exchangers shall be a 4 Pa...

Reviews: