units offer the following advantages:
• Completely pre-charged with Puron 

environmentally sound refrigerant 
(R-410A)

• Easy access for in-place service of 

most components

• Multi-function microprocessor board
• Completely insulated cabinet for 

sound attenuation and weather 
infiltration

• Adjustable fresh air damper
• Tool-less filter replacement
• Weight-supporting, single piece wall 

sleeves (except side access 
sleeves) for various wall 
thicknesses from 5 to 20-in.

• Primary condensate drain 

connection on sleeves with 
secondary overflow to building 
exterior

• All sleeves are shipped with a 

weather guard

• Flush type exterior architectural 

louvers

Features/Benefits

Carrier’s 52V vertical 
packaged unit offers design 
flexibility, quality, reliabilty, 
and multi-function controls

Solid-state circuit board

The circuit board incorporates the fol-
lowing control features:

Evaporator coil low temperature 
protection

 protects the unit. During 

the cooling mode, should the evapora-
tor coil experience either a low tem-
perature condition that could result in 
ice build-up on the coil or a reduced 
airflow situation, a temperature sensor 
attached to the coil will deenergize the 
unit. The sensor will reenergize the 
unit when the coil warms up.

52VCR,VER,VQR,VWR09-24

Vertical Packaged

Terminal Air Conditioners

Cooling Only, Electric Heat,

Heat Pump, or Hot Water Heat Units

with PURON

®

 Refrigerant (R-410A)

9,000 to 24,000 Nominal Btuh

Product
Data

Summary of Contents for 52VCR09

Page 1: ...d with a weather guard Flush type exterior architectural louvers Features Benefits Carrier s 52V vertical packaged unit offers design flexibility quality reliabilty and multi function controls Solid s...

Page 2: ...ch sleeve includes a factory installed weather guard to cover the sleeve opening during construction Unique sleeve drain conden sate system A factory installed drain line connects the evaporator drain...

Page 3: ...24 000 Heater Type 00 None ooling Only VE Cooling with Electric Heat VQ Heat Pump VW Cooling with Hot Water Heat Heat Options 02 2 kW Electric Heat sizes 09 and 12 only 03 3 kW Electric Heat 04 4 kW...

Page 4: ...db 60 F wb indoor entering air temperature and 47 F db 43 F wb air entering outdoor unit ELECTRIC HEATER RATINGS 52VER ELECTRIC HEATING AND 52VQR HEAT PUMP UNITS UNIT COOLING CAPACITY Btuh EER 52VCR...

Page 5: ...9 14 7 20 6 32 4 2 0 9 13 6 19 1 30 0 52VWR18 3 Row Coil 760 4 4 7 21 1 29 5 46 3 3 2 7 20 2 28 3 44 5 2 1 3 18 8 26 3 41 3 680 4 4 7 19 7 27 6 43 4 3 2 7 18 9 26 5 41 6 2 1 3 17 6 24 7 38 8 52VWR24 2...

Page 6: ...opening during construction Exterior grilles architectural louvers The exterior grilles attach to the outside face of the wall sleeve and pro vide protection for the unit Interior panel The interior...

Page 7: ...OUTLET CONDENSER INLET 20 66 41 1 4 20 20 LOW VOLTAGE ELECTRICAL KNOCKOUT SERVICE PULLOUT RETURN AIR 6 1 8 10 52VCR VER COOLING ONLY AND COOLING WITH ELECTRIC HEAT UNITS 52VQR09 24 HEAT PUMP UNITS NOT...

Page 8: ...N AIR SERVICE PULLOUT ELECTRICAL KNOCKOUT BLOWER MOTOR 12 3 3 4 1 1 2 3 3 4 2 16 12 3 4 FILTER HOT WATER INLET 1 HOT WATER COIL 52VWR12 24 COOLING WITH HOT WATER HEAT UNITS a52 1342 NOTES 1 Hot water...

Page 9: ...D EXTERIOR GRILLE WALL SLEEVE DIMENSIONS in LEGEND WALL THICKNESS PART NO H W D T 5 8 in 52VX SS 1 43 3 4 21 3 8 26 9 52VX RS 1 52VX RH 1 8 12 in 52VX SS 2 43 3 4 21 3 8 30 13 52VX RS 2 52VX RH 2 12 1...

Page 10: ...C 400 390 380 370 360 350 335 320 LOW H 310 300 290 280 270 260 250 240 18 HIGH 740 730 715 700 685 670 650 630 MEDIUM C 670 660 645 630 615 600 585 570 LOW H 560 550 545 530 515 500 485 470 24 HIGH 9...

Page 11: ...10 200 19 22 20 25 05 4 5 3 38 15 350 11 500 22 25 25 25 18 0 87 1 8 6 5 43 0 72 1 10 00 12 12 20 20 03 3 2 25 10 200 7 700 15 17 20 20 04 4 3 13 600 10 200 19 22 20 25 05 4 5 3 38 15 350 11 500 22 2...

Page 12: ...500 22 25 25 25 06 6 4 50 20 500 15 350 28 33 30 35 08 8 6 00 27 300 20 500 37 43 40 45 10 9 6 75 30 700 23 000 42 48 45 50 24 2 8 1 3 9 9 54 0 74 1 8 03 3 2 25 10 200 7 700 17 19 20 20 04 4 3 00 13...

Page 13: ...C AND MUST BE REMOVED WHEN INSTALLING THE FRONT DESK SWITCH CAP GRN LOCKOUT COOLING GND COM RV LO TEMP LOCKOUT NO BRN RV DEFROST OUTDOOR COM INDOOR BRN GRN RED WHT BLK FD RC R G Y W R G Y W2 C C LEAD...

Page 14: ...ll energize NOTE All three functions are disabled if the 3 minute time delay is active The unit will operate until the thermostat is satisfied Any time that power is applied to the unit and the ther m...

Page 15: ...off Fan operation will be as specified above Reversing valve will remain active Reversing valve heat pump only Type B valves will energize in Heating mode Reversing valve will turn on 15 seconds prior...

Page 16: ...16 RETURN AIR 6 in MIN TO CONDENSATE DRAIN 52V UNIT 1 4 in MIN 1 2 BUBBLE SEALANT WALL SLEEVE EXTERIOR GRILLE a52 1347 Typical installation...

Page 17: ...nditioning systems be properly sized and installed for each application in order to achieve the desired temperature and humidity levels within the space to be conditioned It is strongly recommended th...

Page 18: ...r motor optional filter grille E Heating Coil 1 Electric heating coil shall be 2 to 10 kW electric 2 Hot water heating coil shall have 3 8 in OD high efficiency rifled copper tubes mechanically bonded...

Page 19: ...and hurricane wall sleeve shall be available for coastal areas 2 A thermostat with adjustable high and low tem perature limits shall be available 3 Interior panel shall be available for field install...

Page 20: ...ue or change at any time specifications or designs without notice and without incurring obligations Pg 20 Catalog No 04 52520003 01 Printed in U S A Form 52V 3PD Replaces 52V 2PD Carrier Corporation S...

Reviews: