GB - 4
Make sure the flexible hose is not kinked or
curved too tightly and that it is placed on a
supporting surface (windowsill, floor...).
Hold the hose end in position with
the fastening strap and suction cup.
Ensure that the expulsion of hot air
from the pipe is free from obstructions.
Move the air conditioner close
to the window, stretching the
hose as little as possible (max.
extension 1100 mm).
STAND-ALONE
Preparation for:
cooling with dehumidification
STAND-ALONE
Preparation for:
dehumidification
The dehumidification only function should
be used if you want to remove moisture
from the room air without lowering the
temperature.
Install the flexible hose onto the air conditioner. To improve the air
conditioner performance make sure that:
- the internal tips of the flexible hose are turned as shown in the
picture;
- the hose is stretched as little as possible;
- the hose is not bent, folded or throttled.
If required, the air conditioner can be
installed through a porthole in the
window or through a hole in the wall
follow the instructions in the manual
relating to this component.
With the unit in the
dehumidification mode,
extract the flexible hose from
the air conditioner and place
it as shown in the picture.
If you want to use a flexible
hose and direct the hot air
flow according to your needs,
place the hose on a
supporting surface.
Air flow
Air flow
To open the window
as little as possible,
place the air outlet
vent onto the
flexible hose and
place them outside
the window.