Performance data (cont)
COOLING CAPACITIES (cont)
50HS048 (4 TONS)
Temp (F)
Air Ent
Outdoor
Coil
(edb)
Indoor Entering Air — Cfm/BF
1400/0.06
1600/0.07
1800/0.08
Evap Air — Ewb (F)
72
67
63*
62
72
67
63*
62
72
67
63*
62
85
TC
52.9 48.4 44.9 44.0 53.9 49.3 45.7 44.9 54.2 49.8 46.2 45.8
SHC 26.3 33.8 32.8 40.8 27.6 36.1 34.9 43.6 28.5 38.0 36.9 45.7
kW
4.82 4.75 4.70 4.68 4.94 4.86 4.82 4.79 5.04 4.97 4.93 4.90
95
TC
50.8 46.3 42.7 41.9 51.7 47.0 43.3 42.8 52.1 47.6 43.8 44.0
SHC 25.6 33.1 31.8 39.7 26.9 35.2 33.9 42.4 28.0 37.3 35.9 44.0
kW
5.30 5.23 5.18 5.15 5.43 5.34 5.29 5.27 5.53 5.45 5.40 5.38
105
TC
48.5 43.9 40.5 39.7 49.2 44.5 41.0 40.9 49.7 45.0 41.5 42.0
SHC 24.8 32.1 30.9 38.6 26.1 34.3 32.9 40.9 27.3 36.4 34.9 42.0
kW
5.83 5.76 5.68 5.66 5.96 5.87 5.80 5.79 6.07 5.99 5.91 5.92
115
TC
46.0 41.4 38.2 37.6 46.7 41.9 38.6 38.9 47.0 42.3 39.0 40.0
SHC 24.1 31.1 29.9 37.5 25.3 33.3 31.9 38.9 26.5 35.4 33.8 40.0
kW
6.42 6.32 6.22 6.20 6.54 6.44 6.34 6.35 6.65 6.55 6.46 6.48
50HS060 (5 TONS)
Temp (F)
Air Ent
Outdoor
Coil
(edb)
Indoor Entering Air — Cfm/BF
1750/0.03
2000/0.04
2250/0.04
Evap Air — Ewb (F)
72
67
63*
62
72
67
63*
62
72
67
63*
62
85
TC
66.3 59.8 55.3 53.6 67.3 60.6 56.1 54.7 67.8 61.1 56.6 56.2
SHC 32.8 42.1 40.8 51.0 34.5 45.0 43.5 54.4 35.8 47.7 46.1 56.2
kW
6.12 5.98 5.87 5.85 6.27 6.12 6.02 5.99 6.40 6.25 6.15 6.15
95
TC
63.4 56.8 52.3 50.8 64.2 57.5 53.0 52.5 64.7 57.9 53.4 53.9
SHC 31.8 41.0 39.6 49.7 33.5 44.0 42.3 52.3 34.9 46.6 44.9 53.9
kW
6.71 6.55 6.45 6.42 6.86 6.68 6.59 6.56 6.98 6.82 6.73 6.73
105
TC
60.2 53.8 49.5 48.2 60.9 54.4 50.0 49.9 61.3 54.8 50.3 51.3
SHC 30.9 40.0 38.4 48.2 32.4 42.8 41.1 49.8 33.9 45.5 43.6 51.3
kW
7.34 7.17 7.06 7.03 7.48 7.31 7.20 7.21 7.61 7.44 7.34 7.39
115
TC
56.8 50.7 46.6 46.0 57.5 51.1 47.0 47.5 57.8 51.4 47.2 48.8
SHC 29.6 38.8 37.2 45.9 31.3 41.7 39.9 47.5 32.9 44.4 42.4 48.8
kW
8.00 7.86 7.72 7.72 8.17 7.99 7.86 7.90 8.29 8.13 8.00 8.08
LEGEND
BF
— Bypass Factor
Edb
— Entering Dry-Bulb
Ewb
— Entering Wet-Bulb
kW
— Total Unit Power Input
Ldb
— Leaving Dry-Bulb
Lwb
— Leaving Wet-Bulb
SHC — Sensible Heat Capacity (1000 Btuh) Net
TC
— Total Capacity (1000 Btuh) Net
*At 75 F entering dry bulb (Tennessee Valley Authority [TVA] rating conditions); all
others at 80 F entering dry bulb.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t
= t
−
ldb
edb
1.10 x cfm
t
= Wet-bulb temperature corresponding to enthalpy of air leaving
lwb
evaporator coil (h
)
lwb
total capacity (Btuh)
h
= h
−
lwb
ewb
4.5 x cfm
Where:
h
= Enthalpy of air entering evaporator coil
ewb
3. The SHC is based on 80 F edb temperature of air entering evaporator coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 − BF) x (edb − 80).
HEATING CAPACITIES
50HS018 (1
1
⁄
2
TONS)
Temp (F)
Air Ent
Indoor
Coil
Indoor
Air
Cfm
(std)
Air Temp Entering Outdoor Coil (F db at 70% rh)
−10
0
10
17
20
30
40
47
50
60
60
525
Cap. 2.83 2.83 5.33 5.33 7.83 7.39
9.58
8.74 10.30 9.32 12.80 11.20 15.90 15.20 18.00 18.00 19.00 19.00 22.50 22.50
kW
1.37
1.43
1.49
1.53
1.55
1.61
1.68
1.73
1.75
1.83
675
Cap. 2.99 2.99 5.57 5.57 8.16 7.69
9.96
9.09 10.70 9.68 13.30 11.70 16.50 15.80 18.70 18.70 19.70 19.70 23.20 23.20
kW
1.43
1.48
1.53
1.57
1.58
1.63
1.69
1.73
1.75
1.80
750
Cap. 3.06 3.06 5.67 5.67 8.29 7.82 10.10 9.23 10.90 9.83 13.50 11.80 16.70 16.00 19.00 19.00 20.00 20.00 23.40 23.40
kW
1.46
1.51
1.55
1.59
1.60
1.65
1.70
1.74
1.76
1.80
70
525
Cap. 2.30 2.30 4.75 4.75 7.20 6.80
8.92
8.13
9.65
8.70 12.10 10.60 15.00 14.40 17.10 17.10 18.10 18.10 21.50 21.50
kW
1.38
1.45
1.52
1.57
1.59
1.66
1.74
1.79
1.82
1.90
675
Cap. 2.44 2.44 4.98 4.98 7.52 7.10
9.30
8.48 10.10 9.07 12.60 11.00 15.70 15.00 17.80 17.80 18.90 18.90 22.40 22.40
kW
1.44
1.50
1.56
1.60
1.62
1.68
1.75
1.80
1.82
1.88
750
Cap. 2.55 2.55 5.11
5.11 7.67 7.23
9.46
8.62 10.20 9.22 12.80 11.20 15.90 15.20 18.10 18.10 19.10 19.10 22.70 22.70
kW
1.47
1.53
1.59
1.63
1.64
1.70
1.76
1.81
1.83
1.89
80
525
Cap. 1.74 1.74 4.14 4.14 6.55 6.19
8.23
7.51
8.95
8.07 11.40
9.95
14.20 13.60 16.20 16.20 17.20 17.20 20.50 20.50
kW
1.37
1.45
1.52
1.57
1.59
1.66
1.74
1.79
1.82
1.90
675
Cap. 1.88 1.88 4.37 4.37 6.87 6.49
8.61
7.85
9.36
8.44 11.90 10.40 14.80 14.20 16.90 16.90 17.90 17.90 21.30 21.30
kW
1.44
1.51
1.59
1.64
1.66
1.73
1.81
1.86
1.88
1.95
750
Cap. 1.97 1.97 4.49 4.49 7.00 6.61
8.76
7.99
9.52
8.58 12.00 10.50 15.00 14.40 17.10 17.10 18.20 18.20 21.70 21.70
kW
1.47
1.54
1.61
1.66
1.68
1.75
1.82
1.87
1.89
1.96
LEGEND
Cap. — Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)
db
— Dry Bulb
kW
— Total Power Input (Includes Compressor Motor Power Input, Outdoor-
Fan Motor Input, and Indoor-Fan Motor Input)
rh
— Relative Humidity
NOTES:
1.
indicates integrated ratings.
2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost
on the outdoor coil and the heat required to defrost it.
12