BEFORE YOU CALL FOR SERVICE,

CHECK FOR SEVERAL EASILY-SOLVED

PROBLEMS

If insufficient heating or cooling is suspected:

(

) Check for sufficient airflow. Check the air filter for dirt.

Check for blocked return-air or supply-air grilles. Be sure
they are open and unobstructed. If these checks do not re-
veal the cause, call your servicing dealer.

If your unit is not operating at all, check the following list

for easy solutions:

(

) Check to be sure that your thermostat temperature se-

lector is set above the indoor temperature during the heating
season, or below the indoor temperature during the cooling
season. Be sure the system switch is in the proper HEAT or
COOL position and not in the OFF position.

(

) Is the electrical supply switch ON? Are any fuses blown,

or has the circuit breaker tripped?

(

) During the heating season, check the external manual

shutoff valve. Is this lever parallel with the pipe, indicating
that the valve is open? Or is the lever at a right angle,
indicating that the valve is closed? If closed, has the gas been
shut off for safety reasons? Otherwise, you may open the
valve and follow the start-up procedures listed in this manual.

NOTE: Before proceeding with the next check, turn OFF
the gas supply, then the electrical power supply to the unit.
Remove the control access door.

(

) During the heating season, check the control switch on

the internal gas valve. Is it in the ON position? If it is not,
be sure it was not turned off for the purpose of safety. If no
safety hazards exist, follow the start-up procedures in this
manual.

(

) If your unit still fails to operate, call your servicing dealer

for troubleshooting and repairs. Specify the model and serial
numbers of your unit. (Record them in this manual in the
space provided.) If the dealer knows exactly which unit you
have, he may be able to offer suggestions over the phone, or
save valuable time through knowledgeable preparation for
the service call.

IN CASE OF TROUBLE

If after performing the above and unit performance is still

unsatisfactory, shut off the unit and call your dealer.

Dealer’s Name

Telephone

Unit Model

Unit Serial Number

8

Summary of Contents for 48SS

Page 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Before performing recommended maintenance be sure gas supply and main power switch to unit are turned off Electrical shock could cause personal injury Mo...

Page 2: ...Set the temperature selector on room ther mostat to desired setting 1 If the main burners fail to light or the blower fails to start shut down gas heating section and call your dealer for service 2 Never attempt to manually light the main burners on unit with a match lighter or any other flame If the electric sparking device fails to light the main burn ers refer to the following shutdown procedur...

Page 3: ...cked at least ev ery 3 or 4 weeks and changed or cleaned whenever it be comes dirty Dirty filters produce excessive stress on the blower motor and can cause the motor to overheat and shut down Table 1 indicates the correct filter size for your unit Refer to Fig 5 to access the filter s To replace or inspect filter s or accessory filter rack when supplied 1 Remove the filter access panel using a 5 ...

Page 4: ...of condenser or evaporator fan bearings or motors is required or recommended Evaporator and Condenser Coils Cleaning of the coils should only be done by qualified service per sonnel Contact your dealer for the required annual maintenance Condensate Drain The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer Compressor Al...

Page 5: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 Fig 3 To Light Unit 5 ...

Page 6: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 Fig 4 To Shut Unit Off 6 ...

Page 7: ...astened securely in place to prevent rain from entering unit cabinet and to pre vent disruption of the correct unit airflow pattern REGULAR DEALER MAINTENANCE In addition to the type of routine maintenance you might be willing to perform your unit should be inspected regu larly by a properly trained service technician An inspection preferably each year but at least every other year should include ...

Page 8: ...right angle indicating that the valve is closed If closed has the gas been shut off for safety reasons Otherwise you may open the valve and follow the start up procedures listed in this manual NOTE Before proceeding with the next check turn OFF the gas supply then the electrical power supply to the unit Remove the control access door During the heating season check the control switch on the intern...

Page 9: ...9 ...

Page 10: ......

Page 11: ...MODEL 48SS WARRANTY 11 ...

Page 12: ... Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 1a 6a PC 111 Catalog No 564 993 Printed in U S A Form 48SS SX 3SO Pg 12 5 98 Replaces 48SS SX 2SO ...

Reviews: