background image

PRECAUTIONS FOR SAFETY

PREPARATION BEFORE USE

2

Preparing Filters

  1. Open the air inlet grille and remove the air

Loading Batteries (when use wireless operation.)

  1. Remove the slide cover.
  2. Insert 2 new batteries (AAA type)

following the (+) and (–) positions.

Clock Setup

 1. 

Push 

 by tip of the pencil.

    If timer indication is 

fl

 ashing, go to the next step 2.

 2. 

Press 

 or 

 : adjust the time.

 3. 

Press 

: Set the time.

Remote Control Reset

 Push 

 by tip of the pencil or

  1. Remove the batteries.

 2. 

Press 

.

  3. Insert the batteries.

Read the precautions 

in this manual carefully 

before operating the unit.

This appliance is 

fi

lled with 

R32.

 Keep this manual where the operator can easily 

fi

nd it.

 Read the precautions in this manual carefully before operating the unit.

 This appliance is intended to be used by expert or trained users in shops, in light 

industry and on farms, or for commercial use by lay persons.

 The precautions described herein are classi

fi

ed as DANGER, WARNING and 

CAUTION. They both contain important information regarding safety. Be sure to 

observe all precautions without fail.

 DANGER

 Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. 

Ask the dealer or the specialist to do this.

 Turning off the power supply will not prevent potential electric shock.

 The appliance shall be installed in accordance with national wiring regulation.

 Means for disconnection from the supply having a contact separation of at least 3 mm in 

all poles must be incorporated in the 

fi

xed wiring.

 The appliance must be stored in a room without continuously operating ignition sources 

(for example, open 

fl

ames, an operating gas appliance or an operating electric heater).

 In order to avoid 

fi

re, explosion or injury, do not operate the unit when harmful gases (e.g. 

fl

ammable or corrosive) are detected near the unit.

 WARNING

 Do not expose your body directly to cool or warm air for a long time.

 Do not insert your 

fi

nger or any article into the air inlet/outlet.

 When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect 

the power supply or turn off the breaker.

 This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety.

 The air conditioner must be installed, maintained, repaired and removed by a quali

fi

ed 

installer or quali

fi

ed service person. When any of these jobs is to be done, ask a quali

fi

ed 

installer or quali

fi

ed service person to do them for you.

 Children should be supervised to ensure that they do not play with the appliance.

 Do not use any refrigerant different from the one speci

fi

ed (R32) for complement or 

replacement. Otherwise, abnormally high pressure may be generated in the refrigeration 

cycle, which may result in a failure or explosion of the product or an injury to your body.

 Do not use means to accelerate the defrosting process or to clean, other than those 

recommended by the manufacturer.

 The appliance shall be stored in a room without continuously operating ignition sources 

(for example: open 

fl

ames, an operating gas appliance or an operating electric heater).

 Be aware that refrigerants may not contain an odour.

 Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to 

heat, 

fl

ames, sparks, or other sources or ignition. Else, it may explode and cause injury 

or death.

 Appliance and pipe-work shall be installed, operated and stored in a room with a 

fl

oor area 

larger than A

min

 m

2

.

How to get A

min

 m

2

 : A

min

 = (M / (2.5 x 0.22759 x h

0

))

2

M is the refrigerant charge amount in appliance in kg. h

0

 is the installation height of 

the appliance in m: 0.6 m for 

fl

oor standing/1.8 m for wall mounted/1.0 m for window 

mounted/2.2 m for ceiling mounted. (For these units recommend installation height 2.5 m)

 CAUTION

 Do not wash the unit with water. It may cause an electric shock.

 Do not use this air conditioner for other purposes such as preserving food, breeding 

animal, etc.

 Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage 

the unit.

 Do not touch aluminium 

fi

n because it may cause an injury.

 Before cleaning the unit, turn off the main switch or the circuit breaker.

 When the unit won’t be used for a long time, turn off the main switch or the circuit breaker.

 It is recommended that maintenance be performed by a specialist when the unit has been 

operated for a long time.

 The manufacturer shall not assume any liability for the damage caused by not observing 

the description of this manual.

INDOOR UNIT DISPLAY

1

 

Display brightness can be adjusted, follow procedure on 

#

AIR FLOW DIRECTION

3

),;

FIX

AIR FLOW

 filters.

2. Attach the filters. (see detail in the installation manual).

1

2

1 Timer (White)
2 Operation (White)

Summary of Contents for 42TVGS018-703

Page 1: ...ENGLISH ภาษาไทย AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TVGS018 024 703 Outdoor unit 38TVGS018 024 703 OWNER S MANUAL R32 1120650208 ...

Page 2: ... the appliance by a person responsible for their safety The air conditioner must be installed maintained repaired and removed by a qualified installer or qualified service person When any of these jobs is to be done ask a qualified installer or qualified service person to do them for you Children should be supervised to ensure that they do not play with the appliance Do not use any refrigerant dif...

Page 3: ... be activated on a daily basis Setting Daily Timer 1 Press Set the ON timer 3 Press 2 Press Set the OFF timer 4 Press button during the or mark flashing During the daily timer is activating both arrows are indicated Note Keep the remote control in accessible transmission to the indoor unit otherwise the time lag of up to 15 minutes will occur The setting will be saved for the next same operation D...

Page 4: ...3 seconds to cancel the operation Pi Pi Pi sound but OPERATION lamp does not blink In case of ON timer or OFF timer are set AUTO RESTART OPERATION does not activate 19 20 For ECO sleep automatically control air flow and automatically turn OFF Press Select 1 3 5 or 9 hrs for OFF timer operation Note The cooling operation the set temperature will increase automatically 1 degree hour for 2 hours maxi...

Page 5: ...รับอากาศนี จะไม ต อให เกิดอันตรายกับเด ก ห ามใช นํ ายาทำความเย นนอกเหนือจากที ระบุไว R โดยการเติมหรือการใช แทนที ไม อย างนั นอาจเกิด ความดันผิดปกติในส วนของวงจรการทำระบบความเย น ซึ งอาจทำให เครื องไม สามารถทำงานได หรือการ ระเบิด หรือการบาดเจ บต อร างกายของและทรัพย สิน อุปกรณ จะต องเก บไว ในห องที ไม มีองค ประกอบให เกิดไฟ เช น เปลวไฟ อุปกรณ ที ใช ก าซ หรือเครื องทำ ความร อน โปรดทราบว าปกตินํ ายาทำค...

Page 6: ...LCD ของ รีโมทคอนโทรล หน าจอการทํางาน ความสว าง หลอดไฟจะสว างเต มที 100 หลอดไฟจะสว าง 50 50 หลอดไฟจะสว าง 50 และไฟแสดงการทํางานจะดับ 50 ป ดหลอดไฟทุกหลอด ป ดทุกหลอด ตามตัวอย างของ และ หลอดไฟจะสว างประมาณ 5 ก อนที จะดับ การตั งล วงหน า 13 ตั งระบบการทํางานที ต องการเพื อการทํางานในครั งต อไป เครื องจะบันทึกการตั งค าไว เพื อ การทํางานในครั งต อไป ยกเว นทิศทางการไหลของอากาศ 1 เลือกระบบการทํางานที ต อง...

Page 7: ... ในกรณีที มีการตั งเวลาเป ด ON หรือการตั งเวลาป ด OFF ระบบนี จะไม ทํางาน 19 20 เพื อการนอนหลับที สบาย ระบบนี จะควบคุมกระแสลมโดยอัตโนมัติและป ดระบบเองอัตโนมัติ กดปุ ม เลือก 1 3 5 หรือ 9 ชั วโมงสําหรับการตั งเวลาป ด หมายเหตุ ในระบบทําความเย น อุณหภูมิที ตั งจะเพิ มขึ นโดยอัตโนมัติ 1 องศา 1 2 ชั วโมง เพิ มสูงสุด 2 องศา ระบบหลับสบาย ป ดเครื องตัดกระแสไฟฟ าเป นอันดับแรก ตัวเครื องภายในและรีโมทคอนโทรล ท...

Page 8: ...1120650208 ...

Reviews: