OPERATION  TIPS

The following events may occur during normal operation.
1.  

Protection of the air conditioner.

         

Compressor protection

         The compressor can't restart for 3-4 minutes after it stops.
         

Anti-cold air (Cooling and heating  models only)

         The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in 
         one of the following three situations and the set temperature has not been reached.
         A)  When heating has just starting.
         B)  Defrosting.
         C)  Low temperature heating.
         The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
         

Defrosting (Cooling and heating models only)

         Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low 
         and humidity is high resulting in lower heating efficiency of the air conditioner. 
         During this condition air conditioner will stop heating operation and start defrosting automatically.
         The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and 
          the amount of frost build up on the outdoor unit.

2. 

A white mist coming out from the indoor unit

         A white mist may generate due to a large temperature difference between air inlet and air outlet 
         on COOL mode in an indoor environment that has a high relative humidity.
         A white mist may generate due to moisture generated from defrosting process  when the  air 
         conditioner restarts in HEAT mode operation after defrosting.

3. 

Low noise of the air conditioner

         You may hear a low hissing sound when the compressor is running or has just  stopped running. 
         This sound is the sound of the refrigerant flowing or coming to  a stop.
         You can also hear a low "squeak" sound when the compressor is running or has just stopped 
         running. This is caused by heat expansion and cold contraction of the plastic parts in the unit 
         when the temperature is changing.
         A noise may be heard due to louver restoring to its original position when power is first turned on.

4. 

Dust is blown out from the indoor unit.

    This is a normal condition when the air conditioner has not been used for a long time or during first 
    use of the unit.

5. 

A peculiar smell comes out from the indoor unit.

    This is caused by the indoor unit giving off smells permeated from building material, from furniture, 
    or smoke. 

6. 

The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and 

     heating models only) mode.

    When indoor temperature reaches the temperature setting on air conditioner, the  compressor will 
    stop automatically, and the air conditioner turns to FAN only mode.  The compressor will start again 
    when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating 
    models only) to the set point.

CARE  AND  MAINTENANCE

Maintenance 

Checks before operation

    If you plan to idle the unit for a long time, perform
    the following:
   (1) Operate the fan for about half a day to dry the 
         inside of the unit.
   (2) Stop the air conditioner and disconnect power. 
         Remove the batteries from the remote controller.
   (3) The outdoor unit requires periodic maintenance 
         and  cleaning. Do not attempt to do this yourself. 
         Contact  your dealer or servicer.

   Check that the wiring is not broken off or 
   disconnected.

   

Check that the air filter is installed.

   Check if  the air outlet or inlet is blocked after the 
   air conditioner has not been used for a long time.
   
   
  

    Do not touch the metal parts of the unit when 
    removing the filter. Injuries can occur when 
    handling sharp metal edges.
    Do not use water to clean inside the air conditioner.
    Exposure to water can destroy the insulation, 
    leading to possible electric shock.
    When cleaning the unit, first make sure that the 
    power and circuit breaker are turned off. 

Caution

Air freshening filter

Air freshening filter

1

2

4. Remove the  Air Freshening Filter from its support 
     frame (on some models).

    

(The optional filter include :Plasma Dust Collector/

      Silver Ion filter /Bio filter /Vitamin C filter/3M air 
      purifier filter, etc. The removing and installation 
      methods are slightly different, see the pictures 
      marked       and       on the left. 
       Clean the air freshening filter  at least once a 
        month, and replace it every 4-5 months.
       Clean it with vacuum cleaner, then dry it in cool 
        place.

5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the 
    unit,  taking care that the left and right edges line 
    up correctly and place filter into position.

.

.

1

2

Do not touch the Plasma Dust Collector 
Filter within 10 minutes after opening the 
front panel, it may cause an electric shock.

Summary of Contents for 42QCR007713GE

Page 1: ...Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshoot...

Page 2: ...ing informations must be followed SOCIABLE REMARK SAFETY PRECAUTIONS OPERATING INSTRUCTIONS CARE AND MAINTENANCE OPERATION TIPS TROUBLESHOOTING TIPS Sociable remark 2 Warning 3 Caution 4 Parts names 5...

Page 3: ...t use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc Do not disassemble or modify unit WARNING Use the correctly rated breaker or fuse There is risk of fire or...

Page 4: ...ding on models at LOW fan speed This will help to dry up the condensed water inside the evaporator and prevent the breeding of mildew Under Anti mildew operation do not restart the air conditioner unt...

Page 5: ...conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Manul operation can be used temporarily in case the remote...

Page 6: ...tioner in AUTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air cond...

Page 7: ...unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating...

Page 8: ...operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between...

Reviews: