Air conditioner maintenance

Cleaning unit coil:
It is recommended to clean the coil at least at the beginning of each
cooling season or when necessary; turn the unit off first.
• Use a vacuum cleaner or a long-bristle brush to avoid damage to

the coil fins.

• Watch the fin edges to avoid injury.
• Damage to the fins may cause reduced coil efficiency resulting in

increased running costs. Use of flames, liquid or aerosol solvents
must be avoided. Use of these substances will cause serious
damage to the panels and electric parts.

Before a long shutdown period

Clean filters and reposition them in the unit.

Keep the unit in operation for half a day in ventilation (fan only)
mode in order to dry all the internal parts.

Switch the electric mains supply off.
Take the batteries out of the controller.

Clean indoor and outdoor units.

Filter cleaning

Clean filters in accordance with the actual operating
conditions and times.

Lift the front panel and pull the air filters downward.

Standard filter cleaning

Vacuum clean or rinse under running water after using a month.
Put the filters back in the correct position.

Cleaning of photocatalytic filters

• Clean photocatalytic filters by washing them under running water

(without any detergent) and regenerate them by exposing ithem
to sunlight for 6 hours.

• Replace photocatalytic filters every two years.
• Replace electrostatic filters every three months.

Washing the front panel

Lift the front panel up to the top of the unit.
Then separate the front panel from the unit.
Rinse the panel under running water, and dry it completely in a
shaded area.

Cleaning, maintenance, before a long shutdown period

Summary of Contents for 42PQV

Page 1: ...42PQV OWNER S MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1...

Page 2: ...re contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System descriptio...

Page 3: ...e control to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains moving parts Ensure that these parts are kept out of the reach of children Maintain th...

Page 4: ...fied service personnel Refer also to Installation Manual Table I Periodical checks Indoor unit Every month Every 4 months Every year Clean air filter 1 Clean drain pipe Change controller batteries Out...

Page 5: ...leaves etc to avoid reduced air circulation Air cleaning system a Standard air filters they eliminate dust and lint b Electrostatic filter photocatalytic filter this effectively eliminates microscopi...

Page 6: ...rnal parts Switch the electric mains supply off Take the batteries out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions...

Page 7: ...ive 11 ON timer selected 12 Night timer active 13 DAILY timer active Everyday 14 ON timer OFF timer and current time 15 OFF timer selected Table II Unit protection devices WARNING During heat pump ope...

Page 8: ...unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will indicate that signal has been received 1 A B D E G H J K M N C F I L O A AM PM A B 1 2 F...

Page 9: ...nit will only emit a beep when the signals are received correctly Selection of the operating mode button A With this button the operating mode of the air conditioner can be selected By repeatedly pres...

Page 10: ...on will stop flashing 7 Louvre positioning Now this icon is flashing Use button to select desired position Press button for confirmation Now all icons are fixed on display If you want to cancel select...

Page 11: ...oid overcooling or overheating during operation The set temperature will change as follows DAILY timer Everyday button J Push the button when the ON or OFF timer is active The icon will appear on disp...

Page 12: ...receiver turn the remote control OFF and repeat the operation pointing the remote control in the correct direction There are obstacles curtains partitions etc between the remote control and the unit...

Page 13: ...42PQV OM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice May 2003 Printed in Korea...

Reviews: