IMPORTANT:

• Make refrigerant connections before electrical

connections.
When disconnecting, disconnect electrical connections before
refrigerant connections.

• For sizes 007 - 009 - 012 - 014 make ground connection prior

to any other electrical connections.

• The mains supply must be connected as follows:

sizes 007 - 009 - 012 - 014: to the indoor unit;
sizes 018 - 024: to the outdoor init.

• Make electrical connections between units prior to proceeding

to mains supply unit connection.

• Before proceeding with the connection to the mains supply

locate live L and neutral N, then make connections as shown
in the wiring diagram.

• Ensure that mains supply connection is made through a switch

that disconnects all poles, with contact gap of a least 3 mm.

• The indoor - outdoor unit connecting wires must be A07 RN-F type

(or higher), with synthetic rubber insulation with Neoprene coating,
according to EN 60335-2-40 and HD277.S1 codes.

• The mains supply connecting cable must be H07 RN-F type (or

higher), with synthetic rubber insulation with neoprene coating,
according to EN 60335-2-40 and HD277.S1 codes.

• Ground connection between indoor and outdoor units is made

via the refrigerant pipes.

Notes:
All field electrical connections are the responsibility of the
installer.

Electrical connection

Indoor unit wiring

• Lift the front panel up to the top of the unit; in this way  the front

panel will be separated from the unit.

• Remove the plastic cover of the terminal board.
• Make the electrical connections to the terminal board as per the

wiring diagram.

• When the electrical connections are completed, refit the terminal

board cover and fix the cables with the special cable holders.

• Fix the front panel to the latch of the frame grille.

Summary of Contents for 42PHQ007

Page 1: ...42PHW 42PHQ 42PHQ K INSTALLATION MANUAL...

Page 2: ...learances 3 Material supplied 3 General information 4 Warnings avoid 5 Installation 6 7 Refrigerant connections 8 Check 9 Electrical connection 10 11 Operating test 12 Address switch 12 Guide for the...

Page 3: ...and delay type fuses refer to the outdoor unit installation instructions Mod 42PHW 42PHQ007 42PHW 42PHQ009 012 014 42PHW 42PHQ 018 024 42PHQ007K 42PHQ009K 012K 014K 42PHQ018K 024K A mm 790 790 1080 B...

Page 4: ...F or higher Electrical connecting cable Cable type A07 RN F synthetic rubber insulation with Neoprene coating between indoor and outdoor unit according to EN IEC 60335 2 40 and HD277 S1 standards Tabl...

Page 5: ...stem consisting of two units manufactured by Carrier Consult the factory or a qualified system engineer prior to connecting this unit to any other manufacturer s outdoor unit Coupling units which have...

Page 6: ...will cause condensate dripping Flattening or kinking the refrigerant pipes or condensate pipes Excessive height difference between outdoor and indoor units see installation manual of outdoor unit Unn...

Page 7: ...ging bracket so that it is level Use a plumb line if necessary Be sure to leave the clearance spaces Refer to page 3 If the wall hanging bracket is not level water may drip onto the floor Install the...

Page 8: ...ch as a screwdriver set between the middle area of the body and bottom right of the wall hanging bracket Connecting the pipe can be done more easily if the unit is inclined Fix the bottom part of the...

Page 9: ...ttings will damage the tube flaring and cause gas leaks Tubing diameter Torque mm inches Nm 6 35 1 4 18 9 52 3 8 42 12 70 1 2 55 15 87 5 8 65 Once all connections have been completed check for leaks b...

Page 10: ...of additional screws After installation if there is a significant gap between the unit and wall it can be adjusted by securing the body to the wall hanging bracket using 2 screws Screw holes can be on...

Page 11: ...ects all poles with contact gap of a least 3 mm The indoor outdoor unit connecting wires must be A07 RN F type or higher with synthetic rubber insulation with Neoprene coating according to EN 60335 2...

Page 12: ...unit Main switch Time delay fuse or circuit breaker see outdoor unit installation manual Heat pump 42PHQ007 007K 009 009K Heat pump 42PHQ012 012K 014 014K Heat pump 42PHQ 018 018K 024 024K R C Y W2 S...

Page 13: ...t operation The swing motor will operate when the indoor fan is operated Operate the unit in accordance with the Owner s Manual and check the following a Indoor unit Do all switches operate normally D...

Page 14: ...tted value Example 1 Step Enter configuration mode Press MODE and FLAP buttons together for 7 seconds 2 Step Unit configuration Display CFG Default Value HP Available Value HP Heat Pump AC Cool Only 3...

Page 15: ...9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14487 November 2001 Supersedes Order No new Printed in Kore...

Reviews: