Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53400011-01

Printed in U.S.A.

Form 40W-3SI

Pg 1 

6-15

Replaces: New

Installation Instructions

Part Number 40WA900011

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . . . . 1

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-4

Piping to Indoor and Outdoor Units

. . . . . . . . . . . . . . . 2

• CONNECTING PIPING

Drain Piping

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

• ROTATING DRAIN CONNECTION

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Fol-

low all local electrical codes during installation. All wiring

must conform to local and national electrical codes. Improper

wiring or installation may damage thermostat.

Understand the signal words — DANGER, WARNING,

and CAUTION. DANGER identifies the most serious hazards

which will result in severe personal injury or death.

WARNING signifies hazards that  could  result  in  personal

injury or death. CAUTION is used to identify unsafe practices,

which would result in minor personal injury or product and

property damage.

Recognize safety information. This is the safety-alert

symbol (

). When this symbol is displayed on the unit and in

instructions or manuals, be alert to the potential for personal

injury. Installing, starting up, and servicing equipment can be

hazardous due to system pressure, electrical components, and

equipment location.

GENERAL

The branch box accessory for the mini VRF (variable refrig-

erant flow) system allows the connection of multiple indoor

units to an outdoor unit. Each branch box allows 4 indoor unit

connections. The accessory is available for use with the mini

VRF (variable refrigerant flow) system units listed in Table 1.

See Fig. 1 for branch box dimensions. Figure 2 shows an ex-

ample installation.

Table 1 — Branch Box Accessory Usage

INDOOR UNIT

SIZES

40WAC Compact Cassette

007,009,012,015

40WAF 4-Way Cassette

009,012,015,018,024,030,048

40WAW High Wall

007,009,012,015,018,024

40WAD Ducted

007,009,012,015,018,024

40WAH High Static

024,030,036,048

40WAU Under Ceiling/Floor

012,018,024,030,036,048

40WAV Vertical

018,024,030,036,048

OUTDOOR UNIT

SIZES

38WAH

036,048

7

11

1

3

 ½

10 

16 

½

¼

a

40-1772

5

8

3

8

2

9

16

2

9

16

2

9

16

7

16

15

16

5

8

9

3

16

12

3

16

15

16

5

1

7

16

1

8

Fig. 1 — Branch Box  Dimensions

NOTE: All dimensions shown
in inches.

40WAC,WAF,WAW,WAD,

WAH,WAU,WAV

Mini VRF (Variable Refrigerant Flow) System

Branch Box Accessory