Index:
1. Indoor DC Fan Motor (control chip is on PCB)
Power on the unit and when the unit is in the
STANDBY
mode, measure the pin1&pin2 voltage of
CN15
, and pin3 of
CN34
in the fan motor
connector. If the voltage value is not in the range shown in Table 12, the PCB has an issue and needs to be replaced.
Table 12 — CN34
Table 13 — CN15
2. Outdoor DC Fan Motor (control chip is in outdoor PCB)
Release the UVW connector. Measure the resistance of U-V, U-W, V-W. If the resistance is not equal to each other, the fan motor has an issue and
needs to be replaced. Otherwise the PCB has an issue and needs to be replaced.
Fig. 17 — Outdoor DC Fan Motor
NO.
COLOR
SIGNAL
VOLTAGE
1
/
/
2
Black
GND
3
Orange
PWM
5-12VDC
4
Blue
FG
0-12DVC
NO.
COLOR
SIGNAL
VOLTAGE
1
Yellow
208/230VAC
2
Black
208/230VAC
3
Yellow-Green
GND