SG-40MAHB-01: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
14
Table 8 — Information Enquiry
When the air conditioner enters the
INFORMATION ENQUIRY
status, it displays the code value for 25 seconds (see Table 9).
Table 9 — Information Enquiry
ENQUIRY INFORMATION
DISPLAYING CODE
MEANING
T1
T1
T1 temp.
T2
T2
T2 temp.
T3
T3
T3 temp.
T4
T4
T4 temp.
T2B
Tb
T2B temp.
TP
TP
TP temp.
TH
TH
TH temp.
Targeted Frequency
FT
Targeted Frequency
Actual Frequency
Fr
Actual Frequency
Indoor Fan Speed
IF
Indoor fan speed
Outdoor Fan Speed
OF
Outdoor fan speed
EXV Opening Angle
LA
EXV opening angle
Compressor continuous running time
CT
Compressor continuous running time
Compressor stop causes
ST
Compressor stop causes
Reserve
A0
Reserve
A1
Reserve
b0
Reserve
b1
Reserve
b2
Reserve
b3
Reserve
b4
Reserve
b5
Reserve
b6
Reserve
dL
Reserve
Ac
Reserve
Uo
Reserve
Td
ENQUIRY INFORMATION
DISPLAY VALUE
MEANING
REMARK
T1,T2,T3,T4, T2B,TP,TH,
Targeted Frequency,
Actual Frequency
-1F,-1E,-1d,-1c,-1b,-1A
-25,-24,-23,-22,-21,-20
1. The displaying temperature is the
actual value.
2.
The temperature is
°
C
no matter what
kind of remote
controller is used.
3. T1,T2,T3,T4,T2B display range:-
25~70, TP display range: -20~130.
4. Frequency display range: 0~159HZ.
5. If the actual value exceeds the range, it
displays the maximum value or mini-
mum value.
-19
—
99
-19
—
99
A0,A1,
…
A9
100,101,
…
109
b0,b1,
…
b9
110,111,
…
119
c0,c1,
…
c9
120,121,
…
129
d0,d1,
…
d9
130,131,
…
139
E0,E1,
…
E9
140,141,
…
149
F0,F1,
…
F9
150,151,
…
159
Indoor fan speed/Outdoor fan speed
0
OFF
1,2,3,4
Low speed, Medium speed, High speed,
Turbo
For some big capacity motors.
14-FF
Actual fan speed = Display value turns to
decimal value and then multiply 10.
The unit is RPM.
For some small capacity motors, the
display value is from 14-FF
(hexadecimal), the corresponding fan
speed range is from 200-2550 RPM.
EXV opening angle
0-FF
Actual EXV opening value = Display
value turns to decimal value and then
multiply by 2.
Compressor continuous running time
0-FF
0-255 minutes
If the actual value exceeds the range, it
displays the maximum value or minimum
value.
Compressor stop causes
0-99
For the detailed meaning, consult with an
engineer
Decimal display
Reserve
0-FF