background image

GB - 7

40 GKX

E N G L I S H

Use of the remote control (if applicable)

Temperature control

UP
(button E)

DOWN
(button F)

Pressing the UP (E 

) and DOWN (F 

) buttons will increase or

decrease the required room temperature value.
The unit will confirm the signal receipt with a “beep”, and the value
of the set temperature on the display will change accordingly. The
temperature can be set between 18

°

C and 29

°

C at 1

°

C intervals.

In the cooling mode, if the temperature selected is higher than the
room temperature the unit will not start. The same applies to the
heating mode, if the selected temperature is lower than the room
temperature.

Timer operating mode selection
(button G)

By pressing button G 

 it is possible to choose one of the following

programs in sequence:

Symbol on display

No

Continuous operation

simbol

(timer OFF)

Programmed start
Programmed stop

Combined program: unit will automatically cycle
ON and OFF as programmed

 Programmed start time

Press button G 

 until the symbol indicating programmed unit

start appears on the display; select the desired starting time in the
following manner:
• After having defined the TIMER program (in this case a

programmed start) the last programmed time will appear on the
display:

• A personalised new start time can be programmed by pressing

buttons H 

 and I 

 until the desired time appears. Each press

of the button will change the time by intervals of 15 minutes,
from 0:00 to 23:45. Press button C 

 to confirm the selection: indi-

cator P 

 on the unit will illuminate and the air conditioner is

ready to start at the selected time. If the unit is in operation when
the confirmation signal is sent (by pressing button C 

), it will

switch OFF and then restart at the new programmed start time.

 Programmed stop time

Press button G 

 until the symbol indicating programmed unit

stop appears on the display. Set the programmed stop time in the
same manner as previously described.
Press button C 

 to confirm the selection.

Indicator P 

 on the unit will illuminate and the unit will start.

If the unit is switched OFF when the confirmation signal is sent (by
pressing button C 

), it will switch ON and then stop at the new

programmed stop time.

Start/stop
(button B)

When the air conditioner is not in operation, the remote control
readout will only display the actual time (if other symbols are
illuminated, turn the remote control OFF by pressing button B 

).

Press button B 

 to start the air conditioner; indicator N 

 on the

unit will illuminate; the last selected and memorised functions will
be shown in the display:
the unit will operate according to the functions selected.
If the unit does not acknowledge the starting signal by emitting a
“beep” sound, and indicator N 

 does not illuminate, the remote

control must be turned OFF (by pressing button B 

) and the

starting operation must be repeated.
Press button B 

 to stop the air conditioner; all indicators on the

unit will be switched OFF, and the remote control will only display
the actual time.
If the unit does not stop, turn the remote control ON (by pressing
button B 

) and repeat the operation. In certain special operating

conditions the fan will continue to run for 30 seconds after the unit
stops:
in this event indicator light Q 

 on the indoor unit will illuminate.

If button B 

 (air conditioner starting) is pressed immediately

after a stop, the compressor will not start for 3 minutes due to the
inherent protection against frequent compressor cycling; in this
case indicator light Q 

 on the unit will also illuminate.

The unit will only emit a “beep”, when the signals are received
correctly.

Timer mode On/off
(button C)

This button allows the air conditioner to operate in the TIMER mode
according to the programs selected with button G 

.

When this function is ON, indicator light P 

 on the unit is illumi-

nated.
After a power failure, indicator light P 

 will flash and the unit will

remain in the operating condition that was in progress before the
power cut.
Power failures will deactivate the TIMER mode: to reactivate the
TIMER mode, press button C 

 twice.

Selection of the operating mode
(button D)

This button selects the operating mode of the air conditioner. Differ-
ent options are available depending on the unit model. By repeat-
edly pressing this button the available modes will be selected in se-
quence and the relevant symbols will appear on the display, while
the unit will acknowledge signal receipt with a confirming “beep”.

Simbol on display

Cooling with dehumidification.

Heating (where available).

Automatic mode.
The air conditioner will automatically switch from heating
(where available) to cooling and vice versa in order to
maintain the selected temperature.

Dehumidification only.
The air conditioner extracts moisture from the air without
changing the room temperature.

Ventilation (fan only).

Summary of Contents for 40 GKX

Page 1: ...40 GKX OWNER S MANUAL ...

Page 2: ...re contained in the present manual Remote controls instructions are contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 2 Unit LEDs and controls 3 Periodical checks 3 Optimum comfort and minimum power consumption 4 Correct cleaning 4 Before a long shutd...

Page 3: ...qualified personnel 1 2 3 4 5 6 7 B A C A Outdoor unit B Indoor unit C Remote control if foreseen 1 Air return 2 Air filters 3 Air supply 4 Operation indicator light and receiver of remote control signals 5 Nameplate 6 Interconnecting tubing 7 Condensate drain open System description Mod 012 018 024 Do not open the remote control to avoid possible damage In case of malfunction contact a qualified ...

Page 4: ...sonnel See Installation Manual Indoor unit Every 6 months Every year Clean air filter 2 1 Clean condensate drain pipe 2 Change the remote control batteries if foreseen Outdoor unit Every 6 months Every year Clean outdoor coil from inside 2 Blow clean electric parts 2 Check tightness of electric connections 2 Clean fan wheel 2 Check tightness of fan unit 2 Clean drainage pan 2 Unit LEDs and control...

Page 5: ...lean indoor and outdoor units Optimum comfort and minimum power consumption Keep room temperature at a comfortable level Only open doors and windows when strictly necessary When cooling avoid direct sunlight in the room if possible draw the curtains or close the shades Do not obstruct the air intake or outlet of the indoor unit Obstructions will cause a reduction in the air flow and the conditioni...

Page 6: ...ton M O D E T E M P E R A T E M P E R A T U R E T U R E T I M E R T I M E R C L O C K C L O C K A I R A E D B C G F I H K J M L BEEP Insert the batteries paying attention to the correct polarity indicated in the battery compartment replace the cover The maximum operating range for the remote control is approximately 6 meters No obstructions e g curtains or plants should be posi tioned between the ...

Page 7: ...n fan only 8 Temperature display 9 Temperature selected 10 Timer operating mode display 11 Combined timer start stop program 12 Night stop function 13 Stop program 14 Start program 15 Clock display 16 Actual time or programmed start stop time 17 Air function display 18 Fan speed 19 Air outlet louvre operation Table II Unit protection devices WARNING Models with electric heaters the unit is fitted ...

Page 8: ... time if other symbols are illuminated turn the remote control OFF by pressing button B Press button B to start the air conditioner indicator N on the unit will illuminate the last selected and memorised functions will be shown in the display the unit will operate according to the functions selected If the unit does not acknowledge the starting signal by emitting a beep sound and indicator N does ...

Page 9: ...st the time shown on the display in the CLOCK section Selecting the fan speed button J The fan speed can be selected by pressing button J Simbol on display Low speed for night operation Medium speed High speed to reach temperature Automatic Fan speed will automatically switch to the value required for optimum comfort When this function is activated the dotted symbols will flash Use of the remote c...

Page 10: ... exhausted replace the batteries The remote control has not been pointed correctly to the unit receiver turn the remote control OFF and repeat the operation pointing the remote control in the correct direction There are obstacles curtains partitions etc between the remote control and the unit repeat the operation after having removed the obstacles The receiver on unit or the remote control is expo...

Page 11: ...nzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14072 74M10 March 1998 Supersedes Order No 14072 74 January 1998 Printed in Italy ...

Reviews: