GB - 7
40 GKX
E N G L I S H
Use of the remote control (if applicable)
Temperature control
UP
(button E)
DOWN
(button F)
Pressing the UP (E
) and DOWN (F
) buttons will increase or
decrease the required room temperature value.
The unit will confirm the signal receipt with a “beep”, and the value
of the set temperature on the display will change accordingly. The
temperature can be set between 18
°
C and 29
°
C at 1
°
C intervals.
In the cooling mode, if the temperature selected is higher than the
room temperature the unit will not start. The same applies to the
heating mode, if the selected temperature is lower than the room
temperature.
Timer operating mode selection
(button G)
By pressing button G
it is possible to choose one of the following
programs in sequence:
Symbol on display
No
Continuous operation
simbol
(timer OFF)
Programmed start
Programmed stop
Combined program: unit will automatically cycle
ON and OFF as programmed
Programmed start time
Press button G
until the symbol indicating programmed unit
start appears on the display; select the desired starting time in the
following manner:
• After having defined the TIMER program (in this case a
programmed start) the last programmed time will appear on the
display:
• A personalised new start time can be programmed by pressing
buttons H
and I
until the desired time appears. Each press
of the button will change the time by intervals of 15 minutes,
from 0:00 to 23:45. Press button C
to confirm the selection: indi-
cator P
on the unit will illuminate and the air conditioner is
ready to start at the selected time. If the unit is in operation when
the confirmation signal is sent (by pressing button C
), it will
switch OFF and then restart at the new programmed start time.
Programmed stop time
Press button G
until the symbol indicating programmed unit
stop appears on the display. Set the programmed stop time in the
same manner as previously described.
Press button C
to confirm the selection.
Indicator P
on the unit will illuminate and the unit will start.
If the unit is switched OFF when the confirmation signal is sent (by
pressing button C
), it will switch ON and then stop at the new
programmed stop time.
Start/stop
(button B)
When the air conditioner is not in operation, the remote control
readout will only display the actual time (if other symbols are
illuminated, turn the remote control OFF by pressing button B
).
Press button B
to start the air conditioner; indicator N
on the
unit will illuminate; the last selected and memorised functions will
be shown in the display:
the unit will operate according to the functions selected.
If the unit does not acknowledge the starting signal by emitting a
“beep” sound, and indicator N
does not illuminate, the remote
control must be turned OFF (by pressing button B
) and the
starting operation must be repeated.
Press button B
to stop the air conditioner; all indicators on the
unit will be switched OFF, and the remote control will only display
the actual time.
If the unit does not stop, turn the remote control ON (by pressing
button B
) and repeat the operation. In certain special operating
conditions the fan will continue to run for 30 seconds after the unit
stops:
in this event indicator light Q
on the indoor unit will illuminate.
If button B
(air conditioner starting) is pressed immediately
after a stop, the compressor will not start for 3 minutes due to the
inherent protection against frequent compressor cycling; in this
case indicator light Q
on the unit will also illuminate.
The unit will only emit a “beep”, when the signals are received
correctly.
Timer mode On/off
(button C)
This button allows the air conditioner to operate in the TIMER mode
according to the programs selected with button G
.
When this function is ON, indicator light P
on the unit is illumi-
nated.
After a power failure, indicator light P
will flash and the unit will
remain in the operating condition that was in progress before the
power cut.
Power failures will deactivate the TIMER mode: to reactivate the
TIMER mode, press button C
twice.
Selection of the operating mode
(button D)
This button selects the operating mode of the air conditioner. Differ-
ent options are available depending on the unit model. By repeat-
edly pressing this button the available modes will be selected in se-
quence and the relevant symbols will appear on the display, while
the unit will acknowledge signal receipt with a confirming “beep”.
Simbol on display
Cooling with dehumidification.
Heating (where available).
Automatic mode.
The air conditioner will automatically switch from heating
(where available) to cooling and vice versa in order to
maintain the selected temperature.
Dehumidification only.
The air conditioner extracts moisture from the air without
changing the room temperature.
Ventilation (fan only).