![Carrier 40 GKX Owner'S Manual Download Page 7](http://html.mh-extra.com/html/carrier/40-gkx/40-gkx_owners-manual_2561936007.webp)
GB - 6
40 GKX
Type of protection
Condition for activation
Cold draft
With fan in AUTOMATIC
:
prevention
indoor fan OFF and
(active on heating)
red LED on selected.
Defrost cycle
Indoor and outdoor fan OFF and
red LED on louvres in a different
(active on heating)
position from that selected.
Electric heater
Fan will stop for 30 sec. after
protection
unit is turned OFF (red LED on).
(unit with electric heater only)
Freeze-up protection
Compressor and outdoor fan OFF
(active on cooling and dehumidification)
Against frequent
Compressor OFF for about 3 minutes
compressor cycling
Display of selected functions
1.
Signal transmission symbol
2.
Operating mode display
3.
Dehumidification only
4.
Cooling and dehumidification
5.
Automatic
6.
Heating
7.
Ventilation (fan only)
8.
Temperature display
9.
Temperature selected
10.
Timer operating mode display
11.
Combined timer start/stop program
12.
Night stop function
13.
Stop program
14.
Start program
15.
Clock display
16.
Actual time or programmed start/stop time
17.
Air function display
18.
Fan speed
19.
Air outlet louvre operation
Table II: Unit protection devices
WARNING:
Models with electric heaters: the unit is fitted with two thermostats - one with automatic reset and one with manual reset. If the manual thermostat also trips the
circuit, investigate and correct the cause. Switch OFF and ON the power supply to the electric heaters in order to reset the thermostat.
During heat pump operation the unit will undergo several defrost cycles to eliminate any ice that may have collected on the outdoor unit in very low ambient