32
Heat pump heating performance continued
See notes on pg. 37.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°
F
–3
7
17
27
37
47
57
EDB
CFM
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Capacity
(MBtuh)
Total
Power
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
38YRA030-31 Outdoor Section With FC4BNF036 Indoor Section continued
65
850
12.9
11.9
2.08
15.5
14.2
2.17
18.5
16.8
2.27
21.9
19.4
2.38
25.7
23.4
2.52
30.0
30.0
2.69
34.9
34.9
2.91
950
13.1
12.0
2.11
15.7
14.4
2.19
18.7
17.0
2.29
22.1
19.6
2.39
26.0
23.7
2.53
30.4
30.4
2.69
35.2
35.2
2.91
1050
13.2
12.2
2.14
15.9
14.6
2.22
18.9
17.2
2.31
22.3
19.8
2.41
26.2
23.9
2.54
30.6
30.6
2.71
35.5
35.5
2.91
70
850
12.7
11.7
2.16
15.4
14.1
2.26
18.3
16.7
2.36
21.6
19.2
2.48
25.4
23.1
2.62
29.7
29.7
2.80
34.5
34.5
3.03
950
12.9
11.9
2.19
15.5
14.3
2.28
18.5
16.9
2.38
21.9
19.4
2.49
25.7
23.4
2.63
30.0
30.0
2.80
34.8
34.8
3.02
1050
13.1
12.0
2.22
15.7
14.4
2.31
18.7
17.0
2.40
22.1
19.6
2.51
25.9
23.6
2.64
30.3
30.3
2.81
35.1
35.1
3.02
75
850
12.5
11.5
2.24
15.3
14.0
2.35
18.1
16.5
2.46
21.4
19.0
2.58
25.1
22.9
2.74
29.4
29.4
2.92
34.1
34.1
3.15
950
12.7
11.7
2.27
15.4
14.2
2.37
18.3
16.7
2.47
21.6
19.2
2.59
25.4
23.1
2.73
29.7
29.7
2.91
34.4
34.4
3.14
1050
12.9
11.9
2.30
15.6
14.3
2.40
18.5
16.9
2.50
21.8
19.4
2.61
25.6
23.3
2.74
29.9
29.9
2.92
34.7
34.7
3.14
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
036
0.97
0.91
CC5A/CD5A/CD5BA
036
0.97
0.93
CD5A/CD5BW
036
0.97
0.91
CD5A/CD5BW
036
0.97
0.93
CD3(A,B)A
036
0.97
0.91
CD3(A,B)A
036
0.97
0.93
CE3AA
036
0.97
0.93
CE3AA
036
0.97
0.95