background image

520 mm

420 mm 

43

 mm

80

How to remove the drain cap

Clip the drain cap by needle-nose 
pliers and pull out.

How to remove the drain hose

  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

  To install the drain hose, insert the drain hose 

fi rmly until the connection part contacts with heat 
insulator, and the secure it with original screw.

How to fi x the drain cap

1) Insert hexagon 
  wrench (4 mm) 
  in a center head.

In case of right or left piping

  After scribing slits of the front panel 

with a knife or a making-off pin, 
cut them with a pair of nippers or 
an equivalent tool.

In case of bottom right or bottom left piping

  After scribing slits of the front panel 

with a knife or a making-off pin, 
cut them with a pair of nippers or 
an equivalent tool.

Liquid side

Gas side

(To the forefront of fl are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)

Use the handle of screwdriver, etc.

Heat insulator

Drain hose

4 mm

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage from the plug.

Slit

Slit

1. Die-cutting front panel slit

  Cut out the slit on the leftward or right side of the front panel for the left 

or right connection and the slit on the bottom left or right side of the front 
panel for the bottom left or right connection with a pair of nippers.

2. Changing drain hose

  For leftward connection, bottom-leftward connection and rearleftward 

connection’s piping, it is necessary to change the drain hose and drain 
cap.

2) Firmly insert the drain cap.

No gap

CAUTION

Firmly insert the drain hose and drain cap; otherwise, water may leak.

Left-hand connection with piping

  Bend the connecting pipe so that it is laid within 43 mm above the wall 

surface. If the connecting pipe is laid exceeding 43 mm above the wall 
surface, the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so as 

not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (fi gure)

Insert a hexagon
wrench (4 mm).

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

Piping and drain hose forming

How to install the air inlet grille on the indoor unit

  When attaching the air inlet grille, 

perform the same process as for 
removal but in reverse order.

Wiring Connection

How to connect the connecting cable

Wiring of the connecting cable can be carried out without removing 
the front panel.

1. Remove the air inlet grille.
  Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local rule) into the pipe hole 

on the wall.

4. Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 15 cm from the front.

5. Insert the connecting cable fully into the terminal block and secure it 

tightly with screws.

6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor 

unit.

1

2

3

110 mm

20 mm

10 mm

80 mm 

Earth line

about 15 cm

Rear right

Rear left

Bottom left

Left

Bottom right

Right

Die-cutting

front panel slit

Changing

dr

ain hose

Piping prepar

ation

CAUTION

  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

  Check local electrical cords and also any specifi c wiring instructions or 

limitations.

NOTE

  Use stranded wire only.

  Wire type  :  H07RN-F or more

Screw

Terminal cover

Terminal block

Cord clamp

Screw

Earth line

Connecting cable

Connecting cable

Stripping length of the connecting cable

4

EN

ES

FR

IT

VT

PL

CZ

RU

CR

HU

TR

NL

GR

SV

FI

NO

DK

RO

BG

EE

LV

SK

SI

VT

1110651131 (01_EN).indd 5

1110651131 (01_EN).indd   5

2/2/09 11:15:09 AM

2/2/09   11:15:09 AM

Summary of Contents for 38NY018

Page 1: ...OMI NORSK DANSK ROM N EESTI LATVISKI SLOVEN INA SLOVEN INA ESPA OL FRAN AIS P C T RK E ENGLISH Indoor unit 42NQ018 024 Series Outdoor unit 38NY018 024 Series AIR CONDITIONER SPLIT TYPE INSTALLATION MA...

Page 2: ...s na Instala o em Regi es com Queda de Neve e Temperaturas Negativas 5 n Liga o das Condutas de Refrigera o 6 n Purga de Ar 6 n Liga es El ctricas 6 n Trabalhos de Electricidade 6 OUTROS 7 n Teste de...

Page 3: ...Instalare Op ionale 2 UNITATE INTERIOAR 3 n Locul de Instalare 3 n Executarea unei G uri i Montarea Pl cii de Instalare 3 n Racordarea Cablurilor 4 n Instalarea evilor i a Furtunului de Evacuare 4 n...

Page 4: ...HEAT SOURCES SUCH AS RADIATORS HEATERS FURNACE STOVES ETC WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT R410A WITH ANY O...

Page 5: ...get slack Make sure to run the drain hose sloped downward The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Left Bottom right Re...

Page 6: ...the pipe hole is above the arrow Pipe hole In case of block brick concrete or similar type walls make 5 mm dia holes in the wall Insert clip anchors for appropriate mounting screws 7 Indoor unit Side...

Page 7: ...ipe is laid exceeding 43 mm above the wall surface the indoor unit may unstably be set on the wall When bending the connecting pipe make sure to use a spring bender so as not to crush the pipe Bend th...

Page 8: ...sion drain hose with shield pipe NOTE The hole should be made at a slight downward slant on the outdoor side CAUTION Arrange the drain pipe for proper drainage from the unit Improper drainage can resu...

Page 9: ...pressure gauge reading is 101 kPa 76 cmHg 5 Close the low pressure side valve handle of the gauge manifold valve 6 Open fully the valve stem of the packed valves both gas and liquid sides 7 Remove th...

Page 10: ...door units are installed in the separated rooms it is not necessary to change the selector switches Check the are nut connections valve stem cap connections and service port cap connection for gas lea...

Page 11: ...does not blink This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure To switch the TEST RUN COOL mode press RESET b...

Reviews: