5. REFRIGERATION CYCLE DIAGRAM
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
*1
During heating overload operation, a value for the high temperature limit control operation is included.
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard 2.72
46.9 High 20/15 7/6
Heating Overload*1
3.70
59.9
Low
27/
−
24/18
Low temperature 2.51
37.2 High 20/
−
−
10/
−
10
Standard 0.91 9.5
High 27/19 35/24
Cooling Overload 1.26
14.6 High 32/23 43/26
Low temperature 0.77
1.5 Low 21/15 21/15
Standar d
pressure P
(MPaG)
Surface temp. of heat
exc hang er inter changing
pipe T1 (°C)
Fan speed
(indoor)
50Hz
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Accumulator
Heat exchanger
Propeller fan
Outdoor unit
Capillary tube
∅
1.2x500
l
Capillary tube
∅
1.5x1500
l
PA145G1C-4FT1
Cooling
Heating
Mark( )means check points of Gas Leak.
O.D.:12.7mm
O.D.:6.35mm
Cooling
Heating
Packed valve
Packed valve
0.39m
(Connecting pipe)
0.49m
(Connecting pipe)
T1
P
Refrigerant
R410A : 1.05 kg.
(
∅
12.7)
(
∅
6.35)
∅
12.7
∅
6.35
•
•