![Carrier 38MHRB series Service Manual Download Page 44](http://html1.mh-extra.com/html/carrier/38mhrb-series/38mhrb-series_service-manual_2560709044.webp)
44
DIAGNOSIS AND SOLUTION (CONT)
Compressor Checking
Measure the resistance value of each winding by using the tester.
Fig. 44 – Tester
Table 20—Compressor Checking
Position
Resistance Value
ASN98D22UFZ
ASM135D23UFZ
ATF235D22UMT
ATF250D22UMT
Blue - Red
1.57
Ω
1.75
Ω
0.75
Ω
0.75 Ω
Blue - Black
Red - Blue
Fig. 45 – Compressor Checking